Power Supply Specifications

Performance Data

Min

Typical

Max

Input Voltage (VAC) 

194

220-240

264

Input Frequency (Hz)

50/60

Input Current (A)

0.15 (240VAC)

0.2 (194VAC)

THD

20

PF

0.9

Output Voltage (VDC)

11.0

12.0

13.0

Output Current (ADC)

2.0

Output Power (W)

25

Environmental Operating Temperature Range

-25°C

+25°C

+50°C*

Environmental Humidity (non-condensing)

95%

Environmental Storage Temperature Range

-10°C

+70°C

Environmental Rating

IP66 rated: must be protected from direct exposure to the weather

Dimensions

5.2 in. x 1.6 in. x 1.2 in. (133 mm x 30.5 mm x 40 mm)

*Maximum case temperature is 75°C

Symptom

Solution

All letters are OFF

•  Recycle AC power, turn it off, then turn on again.

•  If still off, check the power supply DC output voltage using a voltmeter. It should be nominally 12V. 

 

»

If there is DC output, inspect and correct all DC wire damage/polarity issues; If no issue is found, replace the 

OFF-module string. 

 

»

If there is no DC output, have a licensed electrician check the input AC voltage and if there is correct AC voltage, 

replace the power supply. 

 

»

If there is no AC voltage, correct the upstream AC issue.

Some LEDs appear dim

•  Ensure the overall length of the Tetra

®

 LED System does not exceed the maximum load.

•  Ensure the length of supply wire is equal to or below the recommended remote mounting distance.

Some of the letters 

are not illuminated

•  Inspect and correct the wires of the non-illuminated letters for damage/polarity issues; If no issues are found, see the 

troubleshooting solution for “All letters are OFF.”

Shadows

•  Re-route supply wire and secure to the back of the can with electrical grade RTV silicone. Adjust wire connector 

orientation so that it does not cover any LEDs.

•  Adjust LED layout to ensure uniformity of illumination of the face of the letter.

Troubleshooting

Conforms to the following standards: