Power connections
To make the power connections, see
and do the following:
1. Use a screwdriver to loosen the terminal screws (pins 1 and 3) on the provided three-position terminal
block.
2. Insert the flying leads into sockets 1 and 3. The +12V lead at pin 3 and the ground lead at pin 1.
3. Retighten the terminal screws until snug, ensuring that the power leads are secure.
4. Insert the terminal block into the power connector of the SymNet1.
5. Supply power to the unit by plugging the power supply into a properly rated power source.
The power LED illuminates to show that the SymNet1 is receiving power. If it does not illuminate, check the
terminal block connections and the power source.