14
12. Technical specifications of the detectors
SB250 SB2100 SB450 SB4100 SB4200
Maximum protected distance for
interior use
125 m
250 m
125 m
250 m
350 m
Maximum protected distance for
outdoor use with thermostat-
controlled heating
50 m
100 m
50 m
100 m
200 m
Type of detection
Pulsed infrared beam of wavelength 950 nm at a choice of 4
frequencies (channels).
Number of beams
2 beams
4 beams
Detection mode
Both beams interrupted
All 4 beams interrupted
Intruder alarm response time
Adjustable from 50 ms to 600 ms
Interruption alarm response time
Max. 60 seconds, non-adjustable
Typical duration of intruder alarm
Duration of beam interruption, with a minimum of 4 seconds
Power supply
10 V to 15 VDC
Current consumption at 12 VDC:
•
Complete detector
55 mA
55 mA
65 mA
65 mA
65 mA
•
Receiver alone
35 mA
35 mA
40 mA
40 mA
40 mA
•
Transmitter alone
20 mA
20 mA
25 mA
25 mA
25 mA
Heating power supply
10 V to 15 VAC/VDC
Current consumption of heating
alone at 12 VDC:
•
Complete detector
170 mA
170 mA
340 mA
340 mA
340 mA
•
Receiver alone
85 mA
85 mA
170 mA
170 mA
170 mA
•
Transmitter alone
85 mA
85 mA
170 mA
170 mA
170 mA
NC contact tamper detection
output in addition to alarm
yes
NC contact intruder detection
output in addition to alarm
yes
NC contact interruption detection
output in addition to alarm
yes (cutting the intruder alarm)
Capacity of intruder alarm relay
contact
30 VDC – 500 mA
Capacity of interruption alarm
relay contact
30 VDC – 500 mA
Capacity of tamper alarm relay
contact
30 VDC – 50 mA
Operating temperature for
version with
thermostat-controlled heating
-25°C to +55°C
Protection rating
IP44
Weight
0.8 kg
0.9 kg
1.1 kg
1.2 kg
1.2 kg
Electromagnetic compliance
Complies with European standards (
СЄ
label)
Cell direction adjustability
Vertically by +/- 10°
Module direction adjustability
Horizontally by +/- 90°
Built-in alignment features
Optical viewfinder system, outputs for measuring the received signal.