GE RPN2512E Product User Manual Download Page 10

RPN2510EUM  Chapter 7  Rev C  06/2007 

10 

Several advantages are associated with performing hybridizations in bottles, 
namely those of safety and economy as outlined in the introduction. However, 
the use of bottles for hybridizations and washing procedures requires certain 
adaptations to standard protocols.

7.1. Assembly of membranes into bottles

1.

   Add approximately 20 ml 2 × SSC buffer into the hybridization bottle. The 

rotisserie acts as a convenient bottle stand.

2.

   Pre-wet the membrane in 2 × SSC buffer and loosely roll it up.

3.

   Insert the rolled up membrane into the bottle and replace the cap. Ensure 

that the cap is screwed on securely, (hand tight plus a quarter turn). 

DO NOT 

OVERTIGHTEN

, or the thread of the cap can be damaged, leading to leakages. 

4.  

Place the bottle on a flat surface and roll it gently in the opposite direction  to 
that in which the membrane is coiled. This rolling action causes the membrane 
to uncoil, so lining the inner surface of the bottle.

However, studies at GE Healthcare laboratories using a wide range of hybridization 
mesh technologies demonstrate a resulting loss of sensitivity due to partial 
absorption of the probe into the mesh.

A nylon mesh (RPN2519) is available as an optional extra, as it can facilitate easier 
handling of a number of blots and the more fragile nitrocellulose membranes. 
These handling advantages should be considered against the potential loss of 
sensitivity before use.

When a hybridization mesh is used in conjunction with the membrane, the 
following procedure should be adopted:

5.

   Pre-wet the mesh alongside the membrane in 2 × SSC buffer and place the  

prewetted membrane on top of the mesh. The mesh should be slightly larger 
than the blot in all dimensions. Roll both up together, with the mesh on the 
outside of the membrane, and insert into the bottle as described above (7.1.4.).

7.2. Hybridization

1.

   Set the required oven temperature as detailed in section 5.1.

2.

   Discard the 2 × SSC, used in the bottle to unroll the membrane, and replace  

with prehybridization buffer. Recommended volumes are provided in most GE 
Healthcare protocol booklets. Generally a minimum of 10–15 ml per 20 × 20 cm 
blot is advised. Seal the bottle, avoiding overtightening.

3.

   Place the hybridization bottle(s) into the rotisserie (as detailed in section 5.2.) add 

counterbalance bottles if necessary. Place the rotisserie into the oven so that 
the bottles are rotating in the same direction as the membrane is rolled, see 
Figure 3.

7. Hybridization using the rotisserie

rotation of 

membrane

NOTE:

 If placing several small blots into 

one bottle, prewet the membranes as 
above, and space them out along the 
length of the bottle with forceps.

NOTE:

 The use of a mesh in bottle 

hybridizations to ensure uniform 
contact between the membrane 
surface and the buffer has been 
recommended.

Fig 3. 

Rotation of rotisserie

Summary of Contents for RPN2512E

Page 1: ...GE Healthcare Amersham Hybridization oven shaker Product User Manual Codes RPN2510E RPN2511E RPN2512E...

Page 2: ...branes into bottles 10 7 2 Hybridization 10 7 3 Membrane washing procedures 11 7 3 1 Radioactive Hybridizations 11 7 3 2 AlkPhos Direct Hybridizations 11 8 Maintenance care cleaning of the oven shaker...

Page 3: ...perty of their respective owners 2003 2007 General Electric Company All rights reserved First published November 2003 All goods and services are sold subject to the terms and conditions of sale of the...

Page 4: ...eed platform shaker for box hybridizations depurination denaturation and neutralization steps The instrument is Economical bottle hybridization minimizes probe volumes reducing reagent volumes and enh...

Page 5: ...been supplied with a cordset and plug Check that the appropriate plug for your electrical supply has been included If there is any doubt consult a qualified electrician and inform your local GE Health...

Page 6: ...rical Nominal Voltage Hertz Amp Product code 230 V 50 Hz 3 1 A RPN2510E 110 120 V 60 Hz 4 A RPN2511E 100 V 50 60 Hz 4 A RPN2512E Each instrument is supplied with 1 rotisserie RPN2514 6 hybridization b...

Page 7: ...n Shaker is found on the product information label on the rear of the instrument 5 Turn the Mains ON OFF switch 1 on Fig 1 to the ON position 6 The GE Healthcare Hybridization Oven Shaker is now ready...

Page 8: ...o use the platform shaker for sandwich box hybridizations the following procedure should be adopted 1 Open the oven door to its fullest extent lift the rotisserie vertically and store in a safe place...

Page 9: ...sufficient prehybridization buffer to ensure that the entire surface of the membrane is covered Recommended volume surface area ratio is given in most protocol booklets Seal the box or bag securely 4...

Page 10: ...se membranes These handling advantages should be considered against the potential loss of sensitivity before use When a hybridization mesh is used in conjunction with the membrane the following proced...

Page 11: ...e bottle and the membrane thoroughly with 2 SSC and discard 2 Perform the following stringency washes in large volumes 100 ml minimum of the following solutions at a rotisserie speed of 8 rpm 2 10 min...

Page 12: ...be used Fitting of non approved parts may affect the performance of the safety features designed into the instrument 8 1 Error codes faults The Oven has built in fault diagnostics If a fault occurs t...

Page 13: ...ecommended hybridization buffer or extend prehybridization time 2 4 Increase number of buffer changes during the washing stage or increase stringency of final wash 3 1 Load extra lanes with control DN...

Page 14: ...078 100 1200 1500 872 50 1100 1000 603 1000 500 564d 900 310 800 281 700 271 600 234 500 194 400 125c 300 118 200 72 100 a not necessarily the largest size fragment possible only the largest that is r...

Page 15: ...RPN910D 10 10 cm 10 sheets RPN1010D 15 20 cm 10 sheets RPN1520B RPN1520S RPN1520N RPN1520T RPN1520D 20 20 cm 10 sheets RPN2020B RPN2020S RPN2020N RPN2002T RPN2020D RPN2020E RPN2020F 22 2 22 2 cm 10 sh...

Page 16: ...109 membrane RPN1633 hybridization RPN1634 Ready To Go Random prime dCTP only 10 ng 1 g 5 minutes 2 109 membrane 27 9240 01 DNA labelling hybridization beads DNA labelling Megaprime Random prime any...

Page 17: ...before Quantification Recommended application system hybridization light output re probing to detection AlkPhos Direct RPN3690 0 06 pg 1 hour 5 days yes no Single copy Southern and Northerns ECL Direc...

Page 18: ...MP 35 43 cm 50 28 9068 48 Hyperfilm MP Enveloped 18 24 cm 50 28 9068 50 Hypercassette cassettes for autoradiography and light detection Size Code standard Code deep 18 24 cm RPN11642 RPN11628 24 30 c...

Page 19: ...bridization buffer Product name Pack size Code Rapid Hyb buffer Rate enhanced hybridization buffer 125 ml RPN1635 for use with radiolabelled nucleic acid probes 500 m RPN1636 RPN2510EUM Appendix 6 Rev...

Page 20: ...ray RPN2083 455 255 mm 1 tray RPN2093 Safety Tray Liners to match tray 685 455 mm 25 liners RPN1528 to match tray 685 530 mm 25 liners RPN2048 to match tray 530 330 mm 25 liners RPN2058 to match tray...