Chapter 4
–
Installation
RT411
RT411
21
Connectors
Components and connectors
of RT411’s rear panel are shown in figure below.
Figure 4: Connectors of RT411
Table 1: RT411 connectors
Indicator
Description
A
Power supply, high voltage AC/DC or low voltage DC
B
10 optical outputs, ST connectors
C
8 electrical TTL outputs, Euro Type connectors
D
2 electrical TTL outputs, BNC connectors
E
Jumper to select the type (electrical or optical) of input signal for time
reference , Euro Type connector
F
Electrical Input for time reference, Euro Type connector
G
Optical Input for time reference, ST connector
Power Supply
The unit can be powered from a DC or AC power supply within the limits specified.
The power connections must use insulated flameproof flexible cable with a 1.5 mm²
cross section, 70 °C thermal class, and 750 V insulation voltage.
To reduce the risk of electrical shock, pre-insulated tubular pin terminals should be used
on the ends of the power connections.
Figure 5: Pre-insulated tubular pin terminals
The pin terminals must be completely inserted into the connector supplied with the
unity so that no metallic parts are exposed, according to the figure below.