GE RCR 50 - Security PrecisionLine Dual Technology Motion Sensor Installation Instructions Download Page 4

Specifications

I

nput voltage

8.5 to 18VDC (UL: 10 to 16VDC)

Typical current

27mA

Maximum current

35mA

Electrical configuration

Form C

Relay rating

28VDC, 100mA max.

Tamper

100ma, 40VDC

Detection range

50' (15.2m) x 90°

Target velocity

0.5 ft/sec to 5 ft/sec

Alarm duration

5 sec ± 10%

Mounting height

7' to 9' (2.1m to 2.7m)

Operating temperature

32° F to 122° F (0° C to 50° C)

Relative humidity

5 to 93% non-condensing

Dimensions:

2.8" (7.1cm) W
5.1" (13cm) H
2.3" (5.7cm) D

Weight

6 oz (170g)

Color

white

Field wiring size

12-24 AWG

Microwave frequency

5.8GHz

Listing

C-UL US

FCC Compliance

This device complies with Part 15 of the FCC rules.
Operation is subject to the following three conditions:

(1) This device may not cause harmful interference.

(2) This device must accept any interference received,
including interference that may cause undesired
operation

.

(3)

 

Changes or modifications not expressly approved

by the party responsible for complicance could void
the user’s authority to operate the equipment.

FCC ID: CGGAA2

Product Ordering

Model Number

Description

RCR-50

Range-controlled radar, passive infrared detector with form C relay, stealth mode,
tamper contacts, 50 foot (15.2m) maximum range

Accessories

SB01

Swivel-mount bracket

1036806 Rev B  04/04

Tech Support
800-648-7424
FaxBack: 800-483-2495

www.ge-security.com

GE Security
12345 SW Leveton Drive
Tualatin, OR 97062
503-692-4052
USA & Canada: 800-547-2556

GE Security 

g

Summary of Contents for RCR 50 - Security PrecisionLine Dual Technology Motion Sensor

Page 1: ...Use the following guidelines to determine the best location to install the detector Mount the detector so the expected movement of an intruder is across the detection pattern See Figure 1 Mount the detector on a stable surface 7 to 9 feet 2 1 to 2 7m high DO NOT mount the detector within 2 feet 0 6m of metallic objects or within 5 feet 1 5m of florescent lights DO NOT place objects in front of the...

Page 2: ... detector can be mounted on a flat wall or in a corner See Figure 3 5 Pull the wires through the knockout holes and use screws to attach the base to the wall Use screw anchors if necessary 6 Strip 1 4 inch 6 4mm of insulation from each wire 7 Run each wire through the strain relief and under the appropriate screw terminals on the base and tighten the screws See Figure 3 8 Line up the tabs on the b...

Page 3: ...e and walk test the sensor Understanding the LED The multi color LED located on the bottom of the detector indicates the status of the unit as described in the following table SB01 Swivel Mount Bracket For ceiling mount applications that require 90 degree coverage an optional swivel mount bracket SB01 is available from GE Security See Figure 5 Figure 5 SBO1 Swivel Mount Bracket Setting the Jumpers...

Page 4: ...of the FCC rules Operation is subject to the following three conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation 3 Changes or modifications not expressly approved by the party responsible for complicance could void the user s authority to operate the equipment FCC ID CGGAA2 Product...

Reviews: