GE RCR 50 - Security PrecisionLine Dual Technology Motion Sensor Installation Instructions Download Page 3

3

PrecisionLine  RCR-50

Note

You need to set J2 as close to the intended
coverage range as possible. Overshooting the
coverage area may cause false alarms.

J3 LED -

ON = LED enabled (factory default)

OFF = LED disabled

J4 PIR -

ON = Radar only enabled

OFF = PIR and Radar enabled
(factory default)

Maintaining the Detector

When installed and used properly, the detector provides many
years of service with minimal maintenance. You should walk
test the detector annually to ensure proper operation.

Clean the inside of the unit with a soft-bristled brush or
compressed air. Clean the outside with a damp (water) cloth
as needed to keep it free of dust and dirt. Always test the
unit after cleaning.

When the cover is removed, power is interrupted to the
sensor. Once the cover has been replaced, the green LED will
illuminate for 25 seconds while the sensor warms up. After
the green LED goes off, wait one minute and walk test the
sensor.

Understanding the LED

The multi-color LED located on the bottom of the detector
indicates the status of the unit as described in the following
table.

SB01 Swivel-Mount Bracket

For ceiling-mount applications that require 90 degree
coverage, an optional swivel-mount bracket (SB01) is
available from GE Security. See Figure 5.

Figure 5.  SBO1 Swivel-Mount Bracket

Setting the Jumpers

The detector provides jumpers to select the detection range
and PIR and LED operation. See Figure 4.

J2 Range -

 

Use the jumper to cover the center pin and the

pin indicating the desired range. No jumper = 50 feet (15.2m)
and under.

50 feet (15.2m) and under       40 feet (12.2m) and under
(factory default)

30 feet (9.1m) and under

20 feet (6.1m) and under

In Radar-only mode:

LED

Status

Red

Radar detection.

50’

(15.2m)

50’

15.2m)

20’

(6.1m)

20’

(6.1m)

40’

(12.2m)

40’

(12.2m)

30’

(9.1m)

30’

(9.1m)

50’

(15.2m)

50’

(15.2m)

20’

(6.1m)

20’

(6.1m)

40’

(12.2m)

40’

(12.2m)

30’

(9.1m)

30’

(9.1m)

LED

Status

Red

PIR and Radar detection. The detector is

in

alarm and the relay has switched.

Green

PIR detection only (no alarm).

Yellow

Radar detection only (no alarm).

Summary of Contents for RCR 50 - Security PrecisionLine Dual Technology Motion Sensor

Page 1: ...Use the following guidelines to determine the best location to install the detector Mount the detector so the expected movement of an intruder is across the detection pattern See Figure 1 Mount the detector on a stable surface 7 to 9 feet 2 1 to 2 7m high DO NOT mount the detector within 2 feet 0 6m of metallic objects or within 5 feet 1 5m of florescent lights DO NOT place objects in front of the...

Page 2: ... detector can be mounted on a flat wall or in a corner See Figure 3 5 Pull the wires through the knockout holes and use screws to attach the base to the wall Use screw anchors if necessary 6 Strip 1 4 inch 6 4mm of insulation from each wire 7 Run each wire through the strain relief and under the appropriate screw terminals on the base and tighten the screws See Figure 3 8 Line up the tabs on the b...

Page 3: ...e and walk test the sensor Understanding the LED The multi color LED located on the bottom of the detector indicates the status of the unit as described in the following table SB01 Swivel Mount Bracket For ceiling mount applications that require 90 degree coverage an optional swivel mount bracket SB01 is available from GE Security See Figure 5 Figure 5 SBO1 Swivel Mount Bracket Setting the Jumpers...

Page 4: ...of the FCC rules Operation is subject to the following three conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation 3 Changes or modifications not expressly approved by the party responsible for complicance could void the user s authority to operate the equipment FCC ID CGGAA2 Product...

Reviews: