– 36 –
Heavy Frost on Evaporator
Unplug refrigerator. Unplug connector J9
from the main control board. Measure
between blue wire on connector and
orange (neutral) wire on main control
board J7 pin 9.
Are there approximately 37 ohms?
Always check door ajar,
customer usage -
numerous door
openings, etc.
Check wiring harness,
defrost heater, and
defrost overtemperature
thermostat.
NO
Verify thermistors are within
proper range using
thermistor values chart.
Is resistance within range?
Replace main
board.
Check wiring
connections. If
OK, replace
thermistor.
NO
YES
YES
Summary of Contents for PSH23SGNAFBS Series
Page 42: ... 40 Schematic 2 1 3 ...