background image

Optional Undercounter Dimensions and Installation Information 

Listed by 

Underwriters 

Laboratories

For answers to your Monogram,

® 

GE Profile

 or  

GE

®

 appliance questions, visit our website at 

geappliances.com or call GE Answer Center

®

  

service, 800.626.2000.

Note: 36” ribbon cooktops  
are approved for use over GE 30” single wall 
ovens only. 30” ribbon cooktops are approved 
for use over GE 30” and GE 27” single wall 
ovens. Refer to cooktop and wall oven 
installation information packed with products 
for current dimensional data.
Note: CleanDesign or Sealed Burner Gas 
This installation is to achieve minimum gap 
between bottom of countertop and control 
panel. For this installation, the bottom trim will 
not be flush with a typical 4” toe kick
Note: Cabinets installed adjacent to wall ovens 
must have an adhesion spec of at least a 194°F 
temperature rating.
Installation Information: Before installing,  
consult installation instructions packed with  
product for  current dimensional data.

Specification Revised 5/11

220231

PT900SR 

GE Profile

 30" Built-In Single Wall Oven

 

Dimension and installation information are shown in inches.

Power cord

for cooktop

Junction box

for oven

Junction box in

adjacent cabinet

for cooktop

hook-up

2 (two) 90°elbows &

sufficient pipe to

connect in adjacent

cabinet

Right cabinet side

3/4" Support

Shut-off

valve

Pressure

regulator

1/2" Black

iron pipe

Union

Conduit 

48-1/2"

30" built-in

oven

3-1/2" MIN.

Free space

4" To 4-1/2"

3-1/4

22

Side View

30" Oven W/ Rad. Cktp.

4" 

to 

4-1/2"

36" Typical

Countertop height

Power cord

30-3/4" 

to 

31-3/4"

1-1/2" MIN.

Free space

1-1/2" Typical countertop

Side View

22

27-5/16" MAX.

Cutout height

27-1/4" MIN.

Junction box(s) for

oven & radiant

cooktop 22" 

from floor 

of cutout

Add suitable filler to match 

adjacent cabinets when needed

to maintain toe kick alignment

3/4" Support

5

24

25

Gas or electric cooktops may be installed 

over this oven. See cooktop installation 

instructions for cutout size. See label on 

top of oven for approved cooktop models. 

Gas (including the pressure regulator) and 

electrical connections for gas cooktop must 

be located in an adjacent accessible location.  

For a 30" gas cooktop, the connections are  

more conveniently made to the right.

120 Volt

Outlet

Gas

connection

Junction box

location

240/208V

36'' MIN.

4'' To 4-1/2 '' Toe kick allowable

Match toe kick height

 front and two sides  

22'' MIN. above 

support platform

Top and/or side

fillers may be

necessary if unit

is positioned 

between

existing cabinets

28-1/2'' MIN.

28-5/8'' MAX.

3/4'' Support

platform required  

23-1/2" MIN.

Cutout depth

Allow 11/16''

overlap over side 

edges of cutout

1-1/2"

Countertop

27-1/4'' MIN.

27-5/16'' MAX.

Cutout height

With Gas Cooktop 

With Electric Cooktop 

Note: For this installation, the bottom trim will not be flush with a 
typical 4" toe kick.
Note: Cabinets installed adjacent to wall ovens must have an 
adhesion spec of at least a 194°F temperature rating.