Optional Undercounter Dimensions and Installation Information
Listed by
Underwriters
Laboratories
For answers to your Monogram,
®
GE Profile
™
or
GE
®
appliance questions, visit our website at
geappliances.com or call GE Answer Center
®
service, 800.626.2000.
Note: 36” ribbon cooktops
are approved for use over GE 30” single wall
ovens only. 30” ribbon cooktops are approved
for use over GE 30” and GE 27” single wall
ovens. Refer to cooktop and wall oven
installation information packed with products
for current dimensional data.
Note: CleanDesign or Sealed Burner Gas
This installation is to achieve minimum gap
between bottom of countertop and control
panel. For this installation, the bottom trim will
not be flush with a typical 4” toe kick
Note: Cabinets installed adjacent to wall ovens
must have an adhesion spec of at least a 194°F
temperature rating.
Installation Information: Before installing,
consult installation instructions packed with
product for current dimensional data.
Specification Revised 5/11
220231
PT900SR
GE Profile
™
30" Built-In Single Wall Oven
Dimension and installation information are shown in inches.
Power cord
for cooktop
Junction box
for oven
Junction box in
adjacent cabinet
for cooktop
hook-up
2 (two) 90°elbows &
sufficient pipe to
connect in adjacent
cabinet
Right cabinet side
3/4" Support
Shut-off
valve
Pressure
regulator
1/2" Black
iron pipe
Union
Conduit
48-1/2"
30" built-in
oven
3-1/2" MIN.
Free space
4" To 4-1/2"
3-1/4
22
Side View
30" Oven W/ Rad. Cktp.
4"
to
4-1/2"
36" Typical
Countertop height
Power cord
30-3/4"
to
31-3/4"
1-1/2" MIN.
Free space
1-1/2" Typical countertop
Side View
22
27-5/16" MAX.
Cutout height
27-1/4" MIN.
Junction box(s) for
oven & radiant
cooktop 22"
from floor
of cutout
Add suitable filler to match
adjacent cabinets when needed
to maintain toe kick alignment
3/4" Support
5
24
25
Gas or electric cooktops may be installed
over this oven. See cooktop installation
instructions for cutout size. See label on
top of oven for approved cooktop models.
Gas (including the pressure regulator) and
electrical connections for gas cooktop must
be located in an adjacent accessible location.
For a 30" gas cooktop, the connections are
more conveniently made to the right.
120 Volt
Outlet
Gas
connection
Junction box
location
240/208V
36'' MIN.
4'' To 4-1/2 '' Toe kick allowable
Match toe kick height
front and two sides
22'' MIN. above
support platform
Top and/or side
fillers may be
necessary if unit
is positioned
between
existing cabinets
28-1/2'' MIN.
28-5/8'' MAX.
3/4'' Support
platform required
23-1/2" MIN.
Cutout depth
Allow 11/16''
overlap over side
edges of cutout
1-1/2"
Countertop
27-1/4'' MIN.
27-5/16'' MAX.
Cutout height
With Gas Cooktop
With Electric Cooktop
Note: For this installation, the bottom trim will not be flush with a
typical 4" toe kick.
Note: Cabinets installed adjacent to wall ovens must have an
adhesion spec of at least a 194°F temperature rating.