Condenser Fan Circuit
Check for 9-10VDC at CN02 between pins 2 & 3.
Check for approximately 2VDC at CN02 pins
1 & 3.
Ambient temperature affects operation.
If the room temperature is less than 45
°
F, the
fan will not run when the compressor is on
fan will not run when the compressor is on.
Between 45
°
F & 50
°
F, the fan will start 5
minutes after the compressor starts.
Above 50
°
F, or if the ambient thermistor is
open or shorted, the fan is synchronized
with the compressor.
GE Profile 42-48 Refrigerators
(4/1/05)
GE CONFIDENTIAL & PROPREITARY INFORMATION - NOT FOR PUBLIC DISCLOSURE
Copyright 2007 General Electric Company – 12/14/2009
87
g
GE imagination at work