Thermistor Error Defrost Operation
If either evaporator thermistor fails (open or shorted), the power control board (PCB)
defaults to a timed defrost cycle based on cabinet temperature.
If th f
t
th
i t
f il (
h t d) & th f
t
t
If the freezer evaporator thermistor fails (open or shorted) & the freezer temperature
is below 27
°
F (-3
°
C), the freezer defrost heater will be energized for 20 minutes.
If the freezer temperature is above 27
°
F (-3
°
C), the heater will not come on.
If the fresh food evaporator thermistor fails (open or shorted) & the fresh food
temperature is below 68
°
F (20
°
C), the fresh food defrost heater will be energized for
10 minutes.
If the fresh food temperature is above 68
°
F (20
°
C), the heater will not come on.
During thermistor error operation, the control defaults to fresh food defrost every 5
hrs. & freezer defrost every 10 hours of accumulated compressor run time.