Installation Preparation

PREPARE ELECTRICAL WIRING

#282 French

FOR PERSONAL SAFETY:  
Remove house fuse or open circuit breaker 
before beginning installation. Do not use 
an extension cord or adapter plug with this 
appliance.

#282 French

The improper connection of the equipment
grounding conductor can result in a risk 
of electric shock. Check with a qualified 
electrician or service representative if you 
are in doubt that the appliance is properly 
grounded.

For models equipped with power cord:

 Do not modify the plug 

provided with the appliance; if it will not fit the outlet, have a 
proper outlet installed by a qualified technician.

Cabinet Preparation and Wire Routing

• The wiring may enter the opening from either side, rear or the 

floor within the shaded area.

• Cut a 1-1/2" max. diameter hole to admit the electrical cable. 

Cable direct connections may pass through the same hole 
as the drain hose and hot water line, if convenient. If cabinet 
wall is metal, the hole edge must be covered with a bushing. 

Note:

 Power cords with plug must pass through a separate 

hole.

Electrical Connection to Dishwasher

Electrical connection is on the right front of dishwasher.
• For cable direct connections the cable must be routed as 

shown in Figure E. Cable must extend a minimum of 24" from 
the rear wall.

• For power cord connections, install a 3-prong grounding type 

receptacle in the sink cabinet rear wall, 6" min. or 18" max. 
from the opening, 6" to 18" above the floor.

4

Figure E

WARNING

WARNING

Electrical Requirements

• This appliance must be supplied with 120V, 60Hz., and 

connected to an individual properly grounded branch circuit  
protected by a 15 or 20 ampere circuit breaker or time delay 
fuse.

• Wiring must be 2 wire with ground and rated for 75°C (176°F).
• If the electrical supply does not meet the above 

requirements, call a licensed electrician before proceeding.

Grounding Instructions–Cable Direct

This appliance must be connected to a grounded metal, 
permanent wiring system, or an equipment grounding 
conductor must be run with the circuit conductors and be 
connected to the equipment grounding terminal or lead on the 
appliance.

Grounding Instructions–Power Cord Models

This appliance must be grounded. In the event of a malfunction 
or breakdown, grounding will reduce the risk of electric shock 
by providing a path of least resistance for electric current. 
This appliance is equipped with a cord having an equipment 
grounding conductor and a grounding plug. The plug must 
be plugged into an appropriate outlet that is installed and 
grounded in accordance with all local codes and ordinances.

Summary of Contents for Profile PDW8200 Series

Page 1: ...racket or front brace depending on the model The 10 hex head screw is packaged in a small bag within the user bag Use these parts when making electrical connections 2006 General Electric Company Pub No 49 55020 Part No 165D4700P340 ND 06C 1690 4 06 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 282 French THE JUNCTION BOX COVER AND SCREW MUST BE USED DURING THE ELECTRICAL CONNECTION STEPS TO AVOI...

Page 2: ...AL WASH SPEED CYCLE CHINA CRYSTAL RINSE ONLY 2 4 8 DELAY HOURS ADDED HEAT PRE WASH HEATED DRY READ CAREFULLY KEEP THESE INSTRUCTIONS PDW8200 Series PDW9200 Series PDW8400 Series PDW9700 Series PDW8700 Series PDW9800 Series PDW8800 Series PDW9900 Series PDW8900 Series For PDW9700 Series also refer to the Instructions provided on the template packed with that model WD35X1005 IMPORTANT Observe all go...

Page 3: ...te tee for house plumbing if applicable Electrical cable or power cord if applicable Screw type hose clamps Strain relief for electrical connection Hand shut off valve Water line 3 8 min copper Coupler for extending drain line if applicable Hose Clamps 90 Elbow Air Gap Carpenters Square Coupler Drill Bits Electrical Cable Flashlight Hand Valve Hole Saw Bit Level 2 Measuring Tape Nutdriver Hose Cla...

Page 4: ... or disposer connection is less than 18 above floor to prevent siphoning DETERMINE DRAIN METHOD The type of drain installation depends on the following questions Do local codes or ordinances require an air gap Is waste tee less than 18 above floor If the answer to either question is YES Method 1 MUST be used If the answers are NO either method may be used CABINET PREPARATION Drill a 1 1 2 diameter...

Page 5: ...the cable must be routed as shown in Figure E Cable must extend a minimum of 24 from the rear wall For power cord connections install a 3 prong grounding type receptacle in the sink cabinet rear wall 6 min or 18 max from the opening 6 to 18 above the floor 4 Figure E WARNING WARNING Electrical Requirements This appliance must be supplied with 120V 60Hz and connected to an individual properly ground...

Page 6: ...Optional but strongly recommended and may be required by local codes Water connection is on the left side of the dishwasher Install the hot water inlet line using no less than 3 8 copper tubing Route the line as shown in Figure F and extend forward at least 19 from rear wall Adjust water heater to deliver water at 120 F to 150 F at the dishwasher Flush water line to clean out debris The hot water ...

Page 7: ...or PDW9700 series and PDW9900 series otherwise proceed to Step 6 Remove the 2 toekick brace screws from the upper set of mounting holes and toekick brace Set aside for use in Step 19 Figure J STEP 3 REMOVE WOOD BASE INSTALL LEVELING LEGS IMPORTANT Do not kick off wood base Damage will occur Move the dishwasher close to the installation location and lay it on its back Remove the four leveling legs ...

Page 8: ...et aside earlier and remove hose clamp attached to hose Be careful not to damage the drain hose Slip the hose clamp over the pump end of the hose Figure R STEP 10 SLIDE DISHWASHER PARTIALLY INTO CABINET DO NOT PUSH AGAINST FRONT PANEL WITH KNEES DAMAGE WILL OCCUR Slide dishwasher into the opening a few inches at a time As you proceed pull the drain hose through the opening under the sink Stop push...

Page 9: ...shwasher as shown in Figure U Leave a 1 2 minimum gap between the underside of the countertop and the top of the dishwasher door as shown in Figure X Note For flush installations of the PDW9700 Series models cut off the back panel of the tub insulation blanket so that the dishwasher door panel can be aligned with the kitchen cabinet panels Note If the drain hose gets trapped behind the unit it can...

Page 10: ...l in the correct position shown in Step 11 Figure Y Figure Z STEP 13 SECURE DISHWASHER TO COUNTERTOP OR CABINET In this step you will need the 2 Phillips special head screws set aside prior to Step 1 The dishwasher must be secured to the countertop or the cabinet sides When countertops are made of wood use Method 1 When countertops are granite or other materials that will not accept screws use Met...

Page 11: ...s Note TOTAL DRAIN HOSE LENGTH MUST NOT EXCEED 10 FOR PROPER DRAIN OPERATION DRAIN LINE INSTALLATION Connect drain line to air gap waste tee or disposer using either previously determined method Waste Tee Installation Figure HH Disposer Installation Waste Tee Installation Figure JJ Disposer Installation Method 2 Drain Hose Routing Route the drain hose of the dishwasher to a minimum height of 32 fr...

Page 12: ... See Step 2 Figure H If door drops or closes when released adjust spring tension Check to be sure that wiring is secure under the dishwasher not pinched or in contact with door springs or other components See Steps 9 and 10 Check door alignment with tub If door hits tub level dishwasher See Step 12 Pull lower rack out about halfway Check to be sure it does not roll back or forward on the door If t...

Page 13: ...ck drain lines If leaks are found turn off power at the breaker and correct plumbing as necessary Restore power after corrections are made See Step 8 and 15 Open dishwasher door and make sure most of the water has drained If not check that disposer plug has been removed and or air gap is not plugged See Step 15 Also check drain line for kinking Run the dishwasher through another Rinse Only cycle C...

Page 14: ......

Page 15: ......

Page 16: ......

Page 17: ...nsumer Industrial General Electric Company Louisville Kentucky 40225 ge com 2005 General Electric Company Pub No 31 30588 Dwg No 206C1559P127 ND 05A 1183 2 05 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE ...

Reviews: