– 43 –
3.
Remove the complete control panel as-
sembly in order to gain easy access to
the damper door switch and oven cavity
lamp wiring connections.
4.
Remove the upper halogen blower/lamp
assembly.
5.
Disconnect the wiring to the oven cavity
lamp (located at the base of the damper
door assembly - see illustration below),
thermal fuse, damper door motor, and
damper door sensing switch.
6.
Remove the two screws securing the
damper door assembly (see illustration be-
low) and remove the damper door.
MAGNETRON TUBE REMOVAL
To remove the magnetron tube follow these steps:
1.
Remove the oven from the wall plate.
2.
Remove the outer case.
3.
Remove the complete control panel as-
sembly.
4.
Remove the upper halogen blower/lamp
assembly.
5.
Remove the damper door assembly.
6.
Remove the relay board/air guide assem-
bly and rotate it out of the way.
7.
Remove the magnetron blower assembly.
6.
Remove the four screws securing the
magnetron tube to the wave guide and
remove the magnetron tube. Note: the
four screws securing the magnetron tube
to the wave guide are machine screws.
LOWER HALOGEN BLOWER REMOVAL
To remove the lower halogen blower assembly,
follow these steps:
1.
Remove the oven from the wall plate.
2.
Remove the outer case.
3.
Remove the complete control panel as-
sembly.
4.
Remove the upper halogen blower/lamp
assembly.
5.
Remove the damper door assembly.
6.
Remove the relay board/air guide assem-
bly and rotate it out of the way.
7.
Remove the magnetron blower assembly.
8.
Remove the magnetron tube.
DAMPER DOOR
ASSEMBLY
OVEN CAVITY
LAMP
THERMAL
FUSE
DOOR
SENSING
SWITCH
DAMPER
MOTOR