![GE Profile Advantium SCA2000BAA Service Manual Download Page 39](http://html1.mh-extra.com/html/ge/profile-advantium-sca2000baa/profile-advantium-sca2000baa_service-manual_4123374039.webp)
– 37 –
Notice in the illustration below, that the while the
display looks like one complete assembly, it ac-
tually consists of two components (the VFD and
the LED board).
CONTROL PANEL HOUSING SERVICE
Once the control panel assembly is removed, you
can now remove and replace the following com-
ponents:
• Low voltage transformer
• Base hood thermal cut-out (TCO)
• Door switches
• Damper door switch
• Relay board
The low voltage transformer has two mounting
tabs. The back tab fits into a molded holder in
the bottom of the chassis. The front tab is se-
cured to the chassis with a screw.
The relay board can also be replaced from the
front of the unit. Notice in the illustration below
that the relay board is mounted (screwed) to a
plastic housing.
To remove the relay board, remove the screw that
secures the plastic mounting bracket to the metal
frame (remove the relay board and plastic mount-
ing bracket assembly as one unit).
Note: the illustration above shows the oven with
wrapper removed, for detail only. It is not neces-
sary to remove outer wrapper.
OVEN
LOCKED
SELECT
REM
NITE
MUTE
TIMER
Select COOK TIME
2:03 M=10
UPPER PORTION OF FRONT DISPLAY
LOWER PORTION OF FRONT DISPLAY
LED BOARD
VFD
PLASTIC
MOUNTING
BRACKET
RELAY
BOARD
MOUNTING
TAB
Lift upward to release
mounting tab
Remove screw securing relay board plastic mounting
bracket to metal frame