Level II Programming – P Values
Level II program parameters can be adjusted and used
to fine-tune the conditioner’s operation. The parameters
are accessible by pressing and holding the UP and DOWN
buttons until the control displays a “P” value. Note: The
control must be in the home position to change settings.
See Table below for Level ll parameters. Typically the Level
ll parameters will not need to be adjusted, as the default
settings accommodate most applications. Contact your
Water Treatment Professional before attempting any
programming.
P#
Description
Range
Minimum
Increments
Default
Units
Notes
P1
Time of Day
12 Hr
24 Hr
1 Min
12:00PM
Hr./Min.
Range dependent on P10 setting
P2
Day of Week
Sun-Sat
1 Day
Sun
Days
Set to actual day of the week
P3
Time of Regen
12 Hr
24 Hr
1 Min
12:00PM
Hr./Min.
Range dependent on P10 setting
P4
Day Override
0-30
1 Day
0
Days
0 = Disabled
P5
Not Used
P6
Salt Setting
3-18
50-290
1
10
9
110
Lbs/Cu ft
3
g/L
Set in Level I Programming
P7
Capacity
(View Only)
1-140
0.1-14.0
1
0.1
Calculated Kilograins
Kilograms
Values dependent on P9 setting
P8
Not Used
P9
Units of Measure
0-1
1
0
0 = US 1 = Metric
P10 Clock Mode
0-1
1
0
0 = 12 Hr 1 = 24 Hr
P11 Service Interval
0-99
1
0
Months
0 = Disabled 30 Day Month
P12
Minimum
Days Between
Regeneration
0-14
1
0
Days
P13
Low Salt Sensitivity
0-2
1
2
0 = Highest Sensitivity
1 = Mid Sensitivity
2 = Lowest Sensitivity
3 = Turn Off Check Salt Light Function
P14 Disable Probes
0-1
1
0
0 = Normal Operation
1 = Probes Disabled; No Err6
Programming the Lockout Feature
All parameters can be locked out when the control is in
Level ll programming. Simply press the REGEN button
during Level ll programming and a Lock icon will appear
indicating that the specific setting has been locked out.
When locked out, the setting cannot be adjusted. To
disable the Lock Out Feature, press the REGEN button
when in Level ll. The lock icon will not be displayed.