20

 Level II Programming – P Values

Level II program parameters can be adjusted and used 

to fine-tune the conditioner’s operation. The parameters 

are accessible by pressing and holding the UP and DOWN 

buttons until the control displays a “P” value. Note: The 

control must be in the home position to change settings. 

See Table below for Level ll parameters. Typically the Level 

ll parameters will not need to be adjusted, as the default 

settings accommodate most applications. Contact your 

Water Treatment Professional before attempting any 

programming.

P# 

Description

Range

Minimum 

Increments

Default

Units

Notes

P1

Time of Day

12 Hr  

24 Hr

1 Min

12:00PM

Hr./Min.

Range dependent on P10 setting

P2

Day of Week

Sun-Sat

1 Day

Sun

Days

Set to actual day of the week

P3

Time of Regen

12 Hr  

24 Hr

1 Min

12:00PM

Hr./Min.

Range dependent on P10 setting

P4

Day Override

0-30

1 Day

0

Days

0 = Disabled

P5

Not Used

P6

Salt Setting

3-18  

50-290

10

110

Lbs/Cu ft

3

 

g/L

Set in Level I Programming

P7

Capacity              

(View Only)

1-140 

0.1-14.0

1                       

0.1

Calculated Kilograins  

Kilograms

Values dependent on P9 setting

P8

Not Used

P9

Units of Measure

0-1

1

0

0 = US     1 = Metric

P10 Clock Mode

0-1

1

0

0 = 12 Hr     1 = 24 Hr

P11 Service Interval

0-99

1

0

Months

0 = Disabled     30 Day Month

P12

Minimum 

Days Between 

Regeneration

0-14

1

0

Days

P13

Low Salt Sensitivity

0-2

1

2

0 = Highest Sensitivity 

1 = Mid Sensitivity 

2 = Lowest Sensitivity 

3 = Turn Off Check Salt Light Function

P14 Disable Probes

0-1

1

0

0 = Normal Operation 

1 = Probes Disabled; No Err6

Programming the Lockout Feature

All parameters can be locked out when the control is in 

Level ll programming. Simply press the REGEN button 

during Level ll programming and a Lock icon will appear 

indicating that the specific setting has been locked out. 

When locked out, the setting cannot be adjusted.  To 

disable the Lock Out Feature, press the REGEN button 

when in Level ll. The lock icon will not be displayed.

Time/Day

Regeneration Time/Day

Salt Amount

SU MO TU WE TH FR SA DAYS

PM

Capacity

Check Salt

Summary of Contents for Pro Elite 268-716-150-1248

Page 1: ...Pro Elite Professional Series Water Treatment System by GE Operation Manual Pro Elite Analyzer...

Page 2: ...Cursors 17 Button Functions 17 Programming Overview 18 Analyzer Control Operation 18 Level I Programming 18 Level l Programming Analyzer Conditioner 19 Level II Programming P Values 20 Programming the...

Page 3: ...d to minimize the amount of regenerant brine and water used in its operation Efficiency rated water softeners shall have a rated salt efficiency of not less that 3350 grains of total hardness exchange...

Page 4: ...ghtened plumber tape may be used on connections that do not use an O ring seal Do not use pipe dope type sealants on the valve body Do not use pliers or pipe wrenches Do not use petroleum based lubric...

Page 5: ...x 36 48 3 x 91 5 cm 19 x 36 48 3 x 91 5 cm Salt Storage 240 lbs 109 kg 240 lbs 109 kg 240 lbs 109 kg Drain Water Rate 2 7 gpm 10 2 L m 3 9 gpm 14 7 L m 3 9 gpm 14 7 L m Service Connection Size 1 NPT 1...

Page 6: ...conditioner be installed in a protected environment When installing the water conditioning system outdoors several items must be considered Moisture The valve and control are rated for NEMA 3 locatio...

Page 7: ...nism 3 Jacket Resin Tank 11 Tank Collar 4 Base 12 Riser Tube 5 268 Logix PE Valve w 716 Control 13 Upper Basket 6 Resin Tank 14 Cover 7 Door Access Sensor 15 Shield 8 Sensors Wired Probes Brine Tank 1...

Page 8: ...8 Equipment Installation Dimensions 36 9 938 1 60 7 1541 6 28 2 715 9 32 2 817 5 53 4 1356 6 55 1398 1 5 0 127 2 5 63 5...

Page 9: ...Floor Drain Figure 1 Standard Basement Before Installation Cold water lines shown Soft Water Hard Water Outside Faucet Outside Faucet Bath Tub Lavatory Toilet Kitchen Laundry Tubs Pump or Meter Hot W...

Page 10: ...y the cover aside for now To Assemble the Media Tank 1 If the floor under the media tank is uneven the leveling feet may be installed Slowly lay the tank on its side Press or tap the feet into the poc...

Page 11: ...B Y P A S S B Y P A S S Water Conditioner Water Conditioner In Out In Out Figure 7 Model 1265 Bypass Included Water Conditioner Water Conditioner Water Conditioner Water Conditioner Normal Operation I...

Page 12: ...drain line connection This will provide an adequate siphon trap Tie or wire the hose in place at the drain point Also provide an air gap of at least 1 1 2 inch between the end of the hose and the drai...

Page 13: ...ure hose in place Drain Air Gap Figure 12 Electrical Connection Note There are no user serviceable parts in the AC adapter motor or the control board The Analyzer control operates on a 12 volt alterna...

Page 14: ...enerant draw is completed when the air check closes Slow Rinse Downflow Cycle C3 Water flow moves the regenerant through the resin at a specific rate and rinses to the drain The resin is regenerated R...

Page 15: ...optical sensor which is rotated approximately 90 degrees out of phase Note If electrical power is not available the camshaft can be rotated counterclockwise by hand if the motor is removed Cycle Indic...

Page 16: ...sed such as those sold for commercial laundries adjust the dosage accordingly 1 Dosage Polystyrene resin 1 2 fluid ounce 35 5 mL per cubic foot Non resinous exchangers 0 8 fluid ounce 23 7 mL per cubi...

Page 17: ...as a solid icon during regeneration 12 When hourglass is flashing this indicates that the control is moving to a regeneration cycle Appears as a solid icon during a cancelled regeneration and the cont...

Page 18: ...formation in memory for 8 to 24 hours depending on the installation If the super capacitor is exhausted the Analyzer control will display four dashes immediately upon power up The Time of Day and Day...

Page 19: ...ress then or press press then PM Cubic feet 1 0 to 2 0 Lbs ft 3 Time Day Regeneration Time Day Time Day Regeneration Time Day Time Day Regeneration Time Day Time Day Regeneration Time Day Time Day Reg...

Page 20: ...lt Setting 3 18 50 290 1 10 9 110 Lbs Cu ft3 g L Set in Level I Programming P7 Capacity View Only 1 140 0 1 14 0 1 0 1 Calculated Kilograins Kilograms Values dependent on P9 setting P8 Not Used P9 Uni...

Page 21: ...Flow rate dictated by size of drain line flow controller C2 Regenerant Draw Not Adjustable 1 Min See Notes Automatically calculated from resin volume and salt dosage settings C3 Slow Rinse 0 200 1 Min...

Page 22: ...n for three seconds while H4 number of regenerations since last reset is being displayed will reset the numbers stored in H4 H5 H6 H7 and H8 Holding the set key down for three seconds while H9 months...

Page 23: ...rol reaches the backwash cycle the hourglass is no longer displayed and the motor will turn off Pressing the SET button will display the time remaining for the current cycle 4 Fill the media tank with...

Page 24: ...h the control in the treated water position press and hold the REGEN button on the control for five seconds This will initiate a manual regeneration The control will display an hourglass indicating th...

Page 25: ...her regeneration Advance the controller to the brine refill position C8 to prime the line between the regenerant tank and the valve conditioner only A Slowly open the main water supply valve again to...

Page 26: ...immediate manual regeneration A solid regeneration icon will be displayed The control will immediately begin a regeneration Delayed Second Regeneration Pressing and releasing the REGEN button while th...

Page 27: ...27 Pro Elite Valve Exploded View and Parts List BYPASS BYPASS 20 21 22 23 24 1 2 3 4 5 6 7 8 9 10 12 13 14 15 16 17 18 19 11 12...

Page 28: ...18 1010154 O Ring Tank 1 4000585 Skirt Pro Elite Lt Gray 1 19 1232370 O Ring Riser Tube 1 8 1000811 Transformer 120 VAC 60 Hz N American Plug 1 20 4001033 Probe Cable Clips Kit 1 9 3019221 Motor Optic...

Page 29: ...29 19 21 22 23 24 25 2 3 4 5 6 7 9 10 12 13 14 15 16 17 18 11 Conditioner Tank and Regenerant Tank Assembly Exploded View and Parts List 1 A A A 26 20 8 27 28 5 26 29...

Page 30: ...tton GE Logo 1 4 1 26 1234170 Screw 8 18 x 9 16 Type 25 4 10 4000347 Cover Brine Tank Pro Elite 1 27 4001265 Washer Countersunk Finishing SS 4 11 4000348 Collar Brine Tank Pro Elite 1 28 4001266 Screw...

Page 31: ...CH15024 Cap Brine Well 4 Dia Caplug STP 4 1 6 60068 8 06 Brine Float w One Grommet As Purchased 1 7 60002 27 Air Check Assembly 1 8 BR10332 Tubing Insert Brass 2 CH20774 Overflow Fitting Assembly 1 CH...

Page 32: ...ical sensor is connected and in place Verify that motor gear has engaged cam gear If everything is connected try replacing in this order 1 Wire harness motor optical sensor assembly 2 Control Camshaft...

Page 33: ...ing to instructions b Remove restriction c Clean injector and screen d Replace injector and cap Contact dealer e Remove foreign matter from disc and check disc for closing by pushing in on stem Replac...

Page 34: ...Pentair Residential Filtration LLC 5730 North Glen Park Road Milwaukee WI 53209 4454 USA 262 238 4400 Phone 262 238 4402 Fax 2011 Pentair Residential Filtration LLC P N 4001051 Rev D MR14...

Reviews: