Specifications
Input voltage
8.5 to 18VDC (UL: 10 to 16VDC)
Typical current
23mA (LEDs off)
Maximum current
35mA
Electrical configuration
Form C
Relay rating
28VDC, 100mA max.
Tamper
100ma, 40VDC
Detection range
90' (37m) x 90°
Target velocity
0.5 ft/sec to 5 ft/sec
Alarm duration
5 sec ± 10%
Mounting height
8' to 12' (2.4m to 3.7m)
Operating temperature
32° F to 122° F (0° C to 50° C)
Relative humidity
5 to 93% non-condensing
Dimensions:
3.5" (89mm) W
6.1" (155mm) H
3.1" (79mm) D
Weight
6.8 oz (193g)
Color
white
Field wiring size
12-24 AWG
Microwave frequency
5.8GHz
1040656 Rev A 08/03
Product Ordering
Model Number
Description
RCR-90
Dual technology, range-controlled radar, passive infrared detector with form C relay, stealth
mode, tamper contacts, 90 foot (27.4m) maximum range
www.GE-Interlogix.com
© 2003 GE Interlogix
12345 SW Leveton Drive
Tualatin, OR 97062
Phone: 503-692-4052
USA & Canada: 800-547-2556
Technical Service: 800-648-7424
FaxBack: 800-483-2495
GE Interlogix
Maintaining the Detector
When installed and used properly, the detector provides many
years of service with minimal maintenance. You should walk test
the detector annually to ensure proper operation.
Clean the inside of the unit with a soft-bristled brush or com-
pressed air. Clean the outside with a damp (water) cloth as
needed to keep it free of dust and dirt. Always test the unit
after cleaning.
When the cover is removed, power is interrupted to the sensor.
Once the cover has been replaced, the green LED will illuminate
for 25 seconds while the sensor warms up. After the green LED
goes off, wait one minute and walk test the sensor.