Figure 6. Circuit Board

Setting the Jumpers

The detector provides jumpers to select the detection range and
PIR and LED operation. See Figure 6.

J2 Range - Use the jumper to cover the center pin and the pin
indicating the desired range. No jumper = 90 feet (27.4m) and
under.

90 feet (27.4m) and under

80 feet (24.4m) and under

(factory default)

70 feet (21.3m) and under

60 feet (18.3m) and under

Note

You need to set J2 as close to the intended
coverage range as possible. Overshooting the
coverage area may cause false alarms.

J3 LED -

ON = LED enabled (factory default)

OFF = LED disabled

J4 PIR -

ON = Radar only enabled

OFF = PIR and Radar enabled
(factory default)

Understanding the LED

The multi-color LED located on the bottom of the detector
indicates the status of the unit as described in the following table.

In Radar-only mode:

LED

Status

Red

PIR and Radar detection. The detector is
in alarm and the relay has switched.

Green

PIR detection only (no alarm).

Yellow

Radar detection only (no alarm).

LED

Status

Red

Radar detection.

90’

(27.4m)

90’

(27.4m)

60’

(18.3m)

60’

(18.3m)

80’

(24.4m)

80’

(24.4m)

70’

(21.3m)

70’

(21.3m)

90’

(27.4m)

90’

(27.4m)

60’

(18.3m)

60’

(18.3m)

80’

(24.4m)

80’

(24.4m)

70’

(21.3m)

70’

(21.3m)

J3 LED

J4 PIR

J2 Range

J4

J3

J2

Summary of Contents for PrecisionLine RCR-90

Page 1: ...in a corner or on a flat wall Use the following guidelines to determine the best location to install the detector Mount the detector so the expected movement of an intruder is across the detection pattern See Figure 2 Mount the detector on a stable surface 8 to 12 feet 2 4 to 3 7m high DO NOT mount the detector within 2 feet 0 6m of metallic objects or within 5 feet 1 5m of florescent lights DO NO...

Page 2: ...g screw See Figure 1 10 Apply power The green LED should light for approximately 25 seconds and then go out 11 Walk test the coverage pattern as follows Walk throughout the intended coverage area Verify the detector alarms See Understanding the LED Note Most units walk test more accurately if the person testing waits 10 seconds between tripping the unit and walking again This allows the detector t...

Page 3: ...verage area may cause false alarms J3 LED ON LED enabled factory default OFF LED disabled J4 PIR ON Radar only enabled OFF PIR and Radar enabled factory default Understanding the LED The multi color LED located on the bottom of the detector indicates the status of the unit as described in the following table In Radar only mode LED Status Red PIR and Radar detection The detector is in alarm and the...

Page 4: ... relay stealth mode tamper contacts 90 foot 27 4m maximum range www GE Interlogix com 2003 GE Interlogix 12345 SW Leveton Drive Tualatin OR 97062 Phone 503 692 4052 USA Canada 800 547 2556 Technical Service 800 648 7424 FaxBack 800 483 2495 GE Interlogix Maintaining the Detector When installed and used properly the detector provides many years of service with minimal maintenance You should walk te...

Reviews: