PrecisionLine RCR-90
Figure 6. Circuit Board
Setting the Jumpers
The detector provides jumpers to select the detection range and
PIR and LED operation. See Figure 6.
J2 Range - Use the jumper to cover the center pin and the pin
indicating the desired range. No jumper = 90 feet (27.4m) and
under.
90 feet (27.4m) and under
80 feet (24.4m) and under
(factory default)
70 feet (21.3m) and under
60 feet (18.3m) and under
Note
You need to set J2 as close to the intended
coverage range as possible. Overshooting the
coverage area may cause false alarms.
J3 LED -
ON = LED enabled (factory default)
OFF = LED disabled
J4 PIR -
ON = Radar only enabled
OFF = PIR and Radar enabled
(factory default)
Understanding the LED
The multi-color LED located on the bottom of the detector
indicates the status of the unit as described in the following table.
In Radar-only mode:
LED
Status
Red
PIR and Radar detection. The detector is
in alarm and the relay has switched.
Green
PIR detection only (no alarm).
Yellow
Radar detection only (no alarm).
LED
Status
Red
Radar detection.
90’
(27.4m)
90’
(27.4m)
60’
(18.3m)
60’
(18.3m)
80’
(24.4m)
80’
(24.4m)
70’
(21.3m)
70’
(21.3m)
90’
(27.4m)
90’
(27.4m)
60’
(18.3m)
60’
(18.3m)
80’
(24.4m)
80’
(24.4m)
70’
(21.3m)
70’
(21.3m)
J3 LED
J4 PIR
J2 Range
J4
J3
J2