![GE PLS624RT Owner'S Manual And Installation Instructions Download Page 21](http://html.mh-extra.com/html/ge/pls624rt/pls624rt_owners-manual-and-installation-instructions_2200441021.webp)
49-2001048 Rev. 3
INST
ALLA
TION INSTRUCTIONS
Installation Instructions
1. GAS SUPPLY
WARNING
Fire Hazard: Do not use a
IODPHWRFKHFNIRUJDVOHDNV
WARNING
Explosion Hazard: Do not
H[FHHGIWOEVRIWRUTXHZKHQPDNLQJJDV
OLQHFRQQHFWLRQV2YHUWLJKWHQLQJPD\FUDFN
the pressure regulator resulting in fire or
explosion hazard.
WARNING
*DVOHDNVPD\QRWEH
detected by smell alone. Gas suppliers
recommend your purchase and install an
UL approved gas detector. Install and use
in accordance with the manufacturer's
instructions.
Gas Pressure Regulator
<RXPXVWXVHWKHSURSDQHJDVSUHVVXUH
regulator supplied with this range. For proper
operations the inlet pressure to the regulator
should be as follows:
0LQLPXPSUHVVXUH´RI:DWHU&ROXPQ
0D[LPXPSUHVVXUH´RI:DWHU&ROXPQ
&RQQHFWDSURSDQHVXSSO\OLQHZLWKD´)ODUH
Female connection to the regulator in the upper
right rear corner of the cabinet
Tighten the gas line to the regulator using 2
wrenches.
IMPORTANT:
/HDYHDGHTXDWHVSDFHDURXQGWKH
gas supply pipe in case of bend or damage during
installation. Make sure the gas supply pipe cannot
contact any moving parts after installed.
When using pressures greater than ½ psi
N3DWRWHVWWKHJDVVXSSO\V\VWHPRIWKH
59GLVFRQQHFWWKHUDQJHDQGLQGLYLGXDOVKXWRII
valve from the gas supply piping. When using
SUHVVXUHVRIòSVLN3DRUOHVVWRSUHVVXUH
test the gas supply system, simply isolate the
range from the gas supply system by closing the
individual shut-off valve.
3. ELECTRICAL CONNECTION
The power supply wires are located at the top left
corner of the rear of the appliance.
&RQQHFWDSRVLWLYH9SRZHUVXSSO\ZLUHWRWKH
DSSOLDQFHEODFN9ZLUHDQGDQHJDWLYH9
SRZHUVXSSO\ZLUHWRWKHDSSOLDQFHZKLWH9ZLUH
Maximum current draw is less than 2 amp.
NOTE:
Ensure to connect the wires with the
FRUUHFWSRODULW\%ODFNLV³´DQG:KLWHLV³´
Ensure electrical connections are properly
secured.
Ensure electrical supply lines are disconnected,
or power removed at the main fuse or circuit
breaker panel, before servicing the appliance.
2. LEAK CHECK
Ŷ
Make sure all control knobs are in the OFF
position.
Ŷ$SSO\DJDVOHDNGHWHFWLRQOLTXLGWRWKH
connections. Any gas leaks will be indicated by
bubbles.
Ŷ
If a gas leak is detected, tighten the loose joint,
or replace the faulty part with a replacement
part recommended by a GE Appliances
authorized retailer.
CAUTION
PRODUCT DAMAGE HAZARD
•
Connect to 12V DC service only.
•
Connect only to protected circuit fused for
not more than 15 Amps.
RANGE INSTALLATION
Propane Supply
Line Connection
Power Supply
Connection