49-1000713 Rev. 0
43
Performance Data Sheet
Model: GE Appliances XWFE
Ŷ6\VWHPFHUWLILHGE\,$3025 7DJDLQVW16)$16,6WDQGDUGVDQG3IRUWKHUHGXFWLRQRIFODLPVVSHFLILHGRQWKH
performance data sheet and at iapmort.org.
Ŷ$FWXDOSHUIRUPDQFHPD\YDU\ZLWKORFDOZDWHUFRQGLWLRQV
It is essential that the manufacturer’s recommended installation,
maintenance and filter replacement requirements be carried out for the
product to perform as advertised. See Installation Manual for Warranty
information.
Application Guidelines/Water Supply Parameters
6HUYLFH)ORZ
0.5 gpm (1.89 lpm)
Water Supply
Potable Water
Water Pressure
25-120 psi (172-827 kPa)
Water Temperature
))&&
Capacity
170 gallons (643.5 liters)
Substance Tested for Reduction
Influent challenge
concentration
(mg/L)
Maximum permissible
product water
concentration (mg/L)
Avg %
Reduction
Chlorine Taste and Odor
2.0 mg/L +/- 10%
N/A
96.9
Chloramine Taste and Odor
3.0 mg/L +/- 10%
0.5
96.9
Particulate, Class I
At least 10,000/mL
N/A
91.4
Cysts
50,000/L
N/A
>99.99
Lead
0.15
0.01
98.85
Mercury
0.006
0.002
96.3
Asbestos
107 to 108 fibers/ L
N/A
>99
Toxaphene
0.015 +/- 10%
0.003
86.95
VOC (Chloroform surrogate chemical)
0.300
0.015
99.7
Alachlor
0.050
0.001
> 98
$WUD]LQH
0.100
0.003
> 97
%HQ]HQH
0.081
0.001
> 99
Carbofuran
0.190
0.001
> 99
carbon tetrachloride
0.078
0.0018
98
FKORUREHQ]HQH
0.077
0.001
> 99
chloropicrin
0.015
0.0002
99
'
0.110
0.0017
98
GLEURPRFKORURSURSDQH'%&3
0.052
0.00002
> 99
R'LFKORUREHQ]HQH
0.08
0.001
> 99
S'LFKORUREHQ]HQH
0.040
0.001
> 98
1,2-dichloroethane
0.088
0.0048
95
1,1-dichloroethylene
0.083
0.001
> 99
cis-1,2-dichloroethylene
0.170
0.0005
> 99
trans-1,2-dichloroethylene
0.086
0.001
> 99
1,2-dichloropropane
0.080
0.001
> 99
cis-1,3-dichloropropylene
0.079
0.001
> 99
dinoseb
0.170
0.0002
99
Endrin
0.053
0.00059
99
(WK\OEHQ]HQH
0.088
0.001
> 99
HWK\OHQHGLEURPLGH('%
0.044
0.00002
> 99
bromochloroacetonitrile
0.022
0.0005
98
dibromoacetonitrile
0.024
0.0006
98
dichloroacetonitrile
0.0096
0.0002
98
trichloroacetonitrile
0.015
0.0003
98
1,1-dichloro-2-propanone
0.0072
0.0001
99
1,1,1-trichloro-2-propanone
0.0082
0.0003
96
heptachlor (H-34, Heptox)
0.025
0.00001
>99
heptachlor epoxide
0.0107
0.0002
98
hexachlorobutadiene
0.044
0.001
> 98
hexachlorocyclopentadiene
0.060
0.000002
> 99
Lindane
0.055
0.00001
> 99
methoxychlor
0.050
0.0001
> 99
pentachlorophenol
0.096
0.001
> 99
VLPD]LQH
0.120
0.004
> 97
Styrene
0.150
0.0005
> 99
1,1,2,2-tetrachloroethane
0.081
0.001
> 99
Tetrachloroethylene
0.081
0.001
> 99
Toluene
0.078
0.001
> 99
2,4,5-TP (silvex)
0.270
0.0016
99
tribromoacetic acid
0.042
0.001
> 98
7ULFKORUREHQ]HQH
0.160
0.0005
> 99
1,1,1-trichloroethane
0.084
0.0046
95
1,1,2-trichloroethane
0.150
0.0005
> 99
trichloroethylene
0.180
0.0010
> 99
bromoform
0.300
0.015
95
bromodichloromethane
0.300
0.015
95
chlorodibromomethane
0.300
0.015
95
xylenes
0.070
0.001
>99
Meprobamate
400 +/- 20%
60
95.5
Atenolol
200 +/- 20%
30
95.9
&DUEDPD]HSLQH
1400 +/- 20%
200
98.6
'((7
1400 +/- 20%
200
98.6
Metolachlor
1400 +/- 20%
200
98.7
Trimethoprim
140 +/- 20%
20
96.1
Linuron
140 +/- 20%
20
96.6
TCEP
5000 +/- 20%
700
98.1
TCPP
5000 +/- 20%
700
98.1
Phenytoin
200 +/- 20%
30
96
Ibuprofen
400 +/- 20%
60
95.9
Naproxen
140 +/- 20%
20
96.5
Estrone
140 +/- 20%
20
97.1
Bisphenol A
2000 +/- 20%
300
99.1
Nonyl phenol
1400 +/- 20%
200
97.3
NOTE:
While the testing was performed under standard
laboratory conditions, actual performance may vary.
5HSODFHPHQW&DUWULGJH;:)()RUHVWLPDWHGFRVWV
of replacement elements please visit our website at
gewaterfilters.com
.
WARNING
To reduce the risk associated with
ingestion of contaminants:
•
Do not use with water that is microbiologically unsafe
or of unknown quality without adequate disinfection
before and after the system.
Systems certified for cyst
reduction may be used on disinfected water that may contain
filterable cysts.
NOTICE
To reduce the risk of water leakage or flooding, and to
ensure optimal filter performance:
•
Read and follow
use instructions before installation and
use of this system.
• Installation and use
MUST
comply with all state and local
plumbing codes.
•
Do not
install if water pressure exceeds 120 psi (827
kPa). If your water pressure exceeds 80 psi (552 kPa), you
must
install a pressure-limiting valve. Contact a plumbing
professional if you are uncertain how to check your water
pressure.
•
Do not
install where water hammer conditions may occur.
If water hammer conditions exist you
must
install a water
hammer arrester. Contact a plumbing professional if you are
uncertain how to check for this condition.
•
Do not
install on hot water supply lines. The maximum
RSHUDWLQJZDWHUWHPSHUDWXUHRIWKLVILOWHUV\VWHPLV)
(38º C).
•
Protect filter from freezing.
'UDLQILOWHUZKHQWHPSHUDWXUHV
GURSEHORZ)&
• Change the disposable filter cartridge every six months or
sooner if you observe a noticeable reduction in water flow
rate.
)DLOXUHWRUHSODFHWKHGLVSRVDEOHILOWHUFDUWULGJHDW
recommended intervals may lead to reduced filter
performance and cracks in the filter housing, causing water
leakage or flooding.
7KLV6\VWHPKDVEHHQWHVWHGDFFRUGLQJWR16)$16,
53, 401, and P473 for the reduction of the substances listed
below. The concentration of the indicated substances in
water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving
WKHV\VWHPDVVSHFLILHGLQ16)$16,DQG3
XWFE System is certified by IAPMO R&T
against NSF/ANSI Standards 42, 53,
401, and P473 for the reduction of claims
specified on the performance data sheet and
at iapmort.org.