3.6
Motor Wiring
3.6.1
Single-Phase Motors
When initially connecting to the power source, be certain that the motor volt-
age connections and available line voltage are the same. Connect electrical
wires as shown on the motor wiring diagram located on the motor name-
plate, electrical junction box, junction box cover, or wiring tag. Be sure your
pump is electrically grounded at the junction box on the motor.
3.6.2
Three-Phase Motors
The wiring diagram located on the motor nameplate, electrical junction box,
junction box cover, or wiring tag should be used to correctly wire the motor
according to the line voltage available. Be sure your pump is electrically
grounded at the junction box on the motor.
CAUTION:
The 500X, 1000X and 1800X motor adapter pumps have a
threaded motor shaft. Reverse operation can damage the
motor shaft, pump shaft, or centrifugal stages.
Before Starting Three-Phase Motors:
STEPS
1.
Prime pump before applying power to avoid damage to the pump.
2.
Apply power for ONE SECOND MAXIMUM to check the direction of
motor shaft rotation. The motor shaft should turn in a clockwise direc-
tion as viewed from the motor end. The direction of rotation for three-
phase motors may be reversed by interchanging any two (2) leads
(Figure 3.3, Changing Motor Rotation).
Three-phase motors can run in either direction, depending on how
they are connected to the power supply. When the three cable leads
are first connected to the power supply, there is a 50% chance that
the motor will run in the proper direction. To make sure the motor is
running in the proper direction, carefully follow the procedure below.
STEPS
A.
Start the pump and note the pressure and flow rate developed
at the pump discharge.
B.
Stop the pump and interchange any of the two leads.
C.
Start the pump again and recheck the flow rate and pressure.
9
Summary of Contents for OSMONICS TONKAFLO SS1000 SERIES
Page 2: ......
Page 6: ......
Page 17: ...Figure 3 4 Rolling the Leads to Balance Current Draw 11 ...
Page 29: ...8 0 DIMENSIONAL DRAWINGS 8 1 500X Motor Adapter Pumps Figure 8 8 500X Motor Adapter Pump 23 ...
Page 30: ...8 2 500 XB Motor Adapter Pumps Figure 8 9 500 XB Motor Adapter Pump 24 ...
Page 31: ...8 3 1000X and 1800X Motor Adapter Pumps Figure 8 10 1000X and 1800X Motor Adapter Pump 25 ...
Page 32: ...8 4 1800XB Motor Adapter Pumps Figure 8 11 1800XB Motor Adapter Pump 26 ...
Page 33: ...8 5 1800XC Motor Adapter Pumps Figure 8 12 1800XC Motor Adapter Pump 27 ...
Page 34: ...9 0 CUTAWAY DRAWINGS 9 1 X Motor Adapter Pump Figure 9 13 X Motor Adapter Pump 28 ...
Page 35: ...9 2 XB and XC Motor Adapter Pump Figure 9 14 XB and XC Motor Adapter Pump 29 ...
Page 41: ......