NX-4V2 Control
I. GENERAL
DESCRIPTION
The NetworX NX-4V2 represents a new approach to security systems design. Drawing on our experience in the world market as the
largest exporter of USA manufactured controls, we have developed the most flexible, durable, and user-friendly control ever seen in
our industry. Featuring sophisticated software, which allows up to 8 users to interface with 8 zones, and a host of integrated fire,
access, verification, and input/output modules, all reported with the most comprehensive and fast SIA and Contact ID formats. The
NetworX design allows a fully loaded system to be housed in one single metal enclosure, establishing for the first time, a logical
solution and design response to modular systems. A maximum of 8 keypads and 1 other module can be added to expand the
capabilities of the NX-4V2. For product warranty information, please refer to the GE Security Product Catalog.
II. ORDERING
INFORMATION
PART #
DESCRIPTION
PART #
DESCRIPTION
NX-4V2
NX-4V2 Control Only
NX-508E
Eight Output Module
NX-4V2-KIT
NX-4V2 Control, NX-108E LCD Keypad, 16.5V
40VA Transformer
NX-534E **
Two-Way Listen-In Module
NX-108E
8 Zone LED Keypad
NX-540E **
"Operator" Telephone Interface Module
NX-116E
16 Zone LED Keypad
NX-591E **
Cellemetry Interface
NX-124E
24 Zone LED Keypad
NX-1192E
192 Zone LCD Keypad
NX-148E
Alphanumeric 48 Zone LCD Keypad
NX-1208E
8 Zone LED Keypad
NX-200 **
Zone Doubling Kit (Includes 100 3.74k and 100
6.98k resistors)
NX-1248E
48 Zone LCD Keypad
NX-320E
Smart Power Supply and Buss Extender
NX-1308E
8 Zone LED Door Design Keypad
NX-408E #
8 Zone Wireless Expansion Module
(UL listed part #60-904)
NX-1316E
16 Zone LED Door Design Keypad
NX-416E #
16 Zone Wireless Expansion Module
(UL listed part #60-904)
NX-1324E
24 Zone LED Door Design Keypad
NX-448E #
48 Zone Wireless Expansion Module
(UL listed part #60-904)
NX-1448E
48 Zone Fixed Language Icon Keypad
**
These products have not been tested and approved by Underwriters Laboratories, Inc.
#
These wireless devices are only UL listed for residential applications.
IMPORTANT NOTES
•
The maximum number of zones available is 8 regardless of the devices added. Information regarding Zone Doubling is
located on page 38.
•
The NX-4V2 control panel will send an trouble condition once each hour if it senses that no devices have been enrolled. This
report will show “Expander Trouble” – device zero (0).
III. BOARD
INSTALLATION
The metal enclosure should be installed with the door opening from the top to bottom.
Refer to the diagram on the right.
Inside the can, there are four slots for board insertion, two on the top and two on the
bottom of the can. These allow the PC board to be positioned vertically as shown in the
diagram. When you slide the board between the grooves of the slots, make sure the
terminal strip is toward the front opening (toward you) to allow for the wire connections.