background image

14 

KEYPAD CONTROL TONES (BEEPS) 

 
A sounder is built into the keypad.  If programmed, your system keypad may 
sound for any of the following reasons: 
 

 

Beeps for all keypresses. 

 

Sounds a continuous tone during the Entry delay time. 

 

Pulses when a day zone is violated while the system is disarmed. 

 

Pulses when a FIRE zone has a trouble condition. 

 

Beeps 3 times for trying to arm with the “Ready” light off, if “Force Arming” 
has not been selected. 

 

Beeps for 1 second or emits a “ding-dong” sound for the “Chime” feature. 

 

Beeps during an exit delay; beeps rapidly for the last 10 seconds of an exit 
delay; and beeps 1 second at the end of the exit delay. 

 

Pulses when the armed status changes and the AC power is off. 

 

Pulses when the armed status changes and any zone(s) are bypassed. 

 

Pulses when the armed status changes and a low battery is detected. 

 

Pulses when the armed status changes and a Tamper condition is detected. 

 

Pulses when one or more of the following conditions are detected: Zone or 
Box Tamper, Low Battery, AC Power Fail, or Expander trouble. 

Entering a valid code will silence the keypad sounder when it is pulsing.  The 
arm/disarm state of your system will not change when entering a code to silence 
a pulsing keypad sounder.  Please contact your installer if a trouble condition 
exists. 

Summary of Contents for NX-108E - Security NetworX NX-4 System

Page 1: ...NETWORX TM NX 4 User manual...

Page 2: ...te a previous alarm INSTANT Light is on when there is no entry exit delay FIRE Light is on to indicate fire alarm flashes to indicate a trouble condition with your fire system ZONE LIGHTS are on stead...

Page 3: ...s s Auto Bypass s Chime Quick Arm s Auto Instant Communicator Test Re Exit Battery Test Forced Arming s Siren Test s These features should not be enabled on UL listed systems ENTRY EXIT DELAY TIMES Ex...

Page 4: ...F SECURITY YOU WILL OBTAIN WITH THIS SYSTEM RELATES SPECIFICALLY WITH TWO MAJOR FACTORS 1 The quantity quality and placement of security devices attached to this system 2 The knowledge you have of the...

Page 5: ...Arming Your System In The Stay Mode 7 Using The Quick Arm 8 Disarming Your System 8 Cancel Abort Feature 9 Bypassing Zones 9 Group Bypass 9 Unbypassing 9 Turning The Door Chime On And Off 9 CHANGING U...

Page 6: ...ress PIN in lieu of the User PIN will operate normally without additional audible or visual indicators Forced Arming An option that allows the system to be turned on ARMED with one or more zones open...

Page 7: ...t is on during the exit delay During the last 10 seconds of the exit delay the exit light will flash rapidly and the keypads will beep rapidly as a warning to the user that the exit time is about to e...

Page 8: ...programmed for these functions the following reports can be sent Fire Key This key can activate the fire alarm when pressed for two seconds If your system is connected to a monitoring center an emerg...

Page 9: ...end of the exit delay the keypads beep one longer tone 1 second The user may wish to disarm and re arm the system if more time is needed ARMING YOUR SYSTEM IN THE STAY MODE STAY is used when the user...

Page 10: ...or ARMING ONLY and will not disarm the security system This is ideal for a maid or baby sitter code etc CHANGING MODES WHILE YOUR SYSTEM IS ARMED Pressing the STAY key will turn on off toggle a delay...

Page 11: ...ASS key again Step 5 The corresponding zone light will illuminate indicating the zone has been bypassed Repeat steps 3 and 4 for any other zone s that need to be bypassed Step 6 Press the BYPASS key a...

Page 12: ...r code needs to be programmed return to Step 5 Step 9 Press the key while the ready light is flashing to exit the User Code Programming Mode ASSIGNING USER CODE AUTHORITY LEVELS Assign authority level...

Page 13: ...to all user numbers Step 7 Press the key to exit the Assigning Authority Level Program OTHER KEYPAD FUNCTIONS SETTING THE KEYPAD TONE Step 1 Press r 0 Keypad is now in the Adjust Tone mode Step 2 Pres...

Page 14: ...d The number of the faulted zone s will be displayed on the LCD keypad It will also be entered into alarm memory and the internal log Step 3 The keypad will begin to beep after 15 minutes in this mode...

Page 15: ...For 2007 enter 0 7 SETTING THE SYSTEM CLOCK Step 1 Press r 9 7 Step 2 Enter the Master Code Step 3 Enter the hour code which must be two 2 digits Note The clock is a 24 hour clock Refer to the followi...

Page 16: ...idly for the last 10 seconds of an exit delay and beeps 1 second at the end of the exit delay Pulses when the armed status changes and the AC power is off Pulses when the armed status changes and any...

Page 17: ...that are tampered Press the key to return to the 1 of 8 service lights 3 ZONE LOW BATTERY Press the 3 key The zone light s will illuminate showing which zone s has a low battery This only applies to w...

Page 18: ...dures In a home sleep with bedroom door closed this will increase your escape time If you suspect fire test the door for heat If you think it is safe brace your shoulder against the door and open it c...

Page 19: ...17 SYSTEM NOTES...

Page 20: ...NX 4 USER S MANUAL NX4UD04 REV D FEB 2004...

Reviews: