NX-6V2 Control
25
LOCATIONS 88-91 ARE FOR PROGRAMMING DIFFERENT ACCOUNT CODES AND / OR FEATURES FOR EACH
PARTITION. IF A LOCATION IS LEFT UN-PROGRAMMED,
THE FEATURE FOR PARTITION 1 AND ACCOUNT CODE FOR THE PHONE NUMBER WILL BE USED.
88
ACCOUNT CODE FOR PARTITION 1
6............. numerical
Location 88 contains the account code sent when partition 1 is reported.
If location 88 is left unprogrammed (all
A
10"s), then the
account code corresponding to the Phone number dialed will be used.
If the account code is less than six digits, program a
A
10" in
the segment immediately after the last digit of the account code. If the account code is 6 digits long, program all 6 segments.
89
ACCOUNT CODE FOR PARTITION 2
6............. numerical
Location 89 contains the account code sent when partition 2 is reported.
If location 89 is left unprogrammed (all
A
10"s), then the
account code corresponding to the Phone number dialed will be used.
If the account code is less than six digits, program a
A
10"
in the segment immediately after the last digit of the account code. If the account code is 6 digits long program all 6 segments.
90
PARTITION 2 FEATURE AND REPORTING SELECTIONS
5............. feature select
Location 90 is used to enable certain features that can be accessed or are visible to the user from the keypad of the system. In
addition, certain communicator reports are enabled in this location. Each of these features can be enabled by partition. This location
contains 5 segments, with eight possible features per segment. Refer to Location 23 (page 15) for the feature selections.
If all
segments are blank (nothing enabled), the features for partition 1 will be used.
91
PARTITION 2 ENTRY EXIT TIMERS
6............. numerical
Location 91 is used to enter in seconds the Entry and Exit times. There are 2 separate entry and exit times. Valid entries are 10-255
seconds.
If all segments are
A
0", the entry and exit times for partition 1 will be used.
Segment 1, Entry time 1:
Entry time that will be used when a Delay 1 zone type initiates an entry delay.
Segment 2, Exit time 1
: Exit time that will be used for all zones designated as Delay 1.
Segment 3, Entry time 2:
Entry time that will be used when a Delay 2 zone type initiates an entry delay.
Segment 4, Exit time 2:
Exit time that will be used for all zones designated as Delay 2.
Segments 5 & 6:
Reserved
92 - 109
RESERVED
LOCATIONS 110-169 ARE USED TO CHANGE THE ZONE TYPES (Configurations) AS LISTED IN THE TABLE
ON PAGE 16. THESE LOCATIONS ARE CONSIDERED ADVANCED PROGRAMMING AND SHOULD
ONLY BE CHANGED WITH A THOROUGH UNDERSTANDING OF THE OPERATION OF EACH BIT.
110
ZONE TYPE 1 ALARM EVENT CODE
1............. numerical
Location 110 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen from the list on
page 16. The zone ID will be that zone that is in alarm.
4+2 Format Note
: If 4+2 format is being used, the number programmed in this location will be sent as the upper hex digit. The digit in
location 110 should be from 1 to 15 when using 4+2 formats. The zone ID or user ID will be the lower hex digit of the zone that is in
alarm.
111
ZONE TYPE 1 CHARACTERISTIC SELECT
5............. feature select
Segment 1:
1 = Fire (turn on if this is a fire zone).
2 = 24 hour (turn on for non-fire 24 hour zones).
3 = Keyswitch zone. (normally open switch)
4 = Follower (turn on for burglary zones that are Instant during non-entry times).
5 = Delay 1 zone (follows timer 1 entry and exit times).
6 = Delay 2 zone (follows timer 2 entry and exit times).
7 = Interior (turn on if this zone should Automatically Bypass or Bypass for Stay Arming).
8 = Local only (turn on if this zone should not be reported).
Segment 2:
1 = On if Zone Type will beep the keypad for alarm.
2 = On if Zone Type will sound the yelping siren for alarm.
3 = On if Zone Type will sound the temporal siren for alarm.
4 = On if Zone Type will chime.
5 = On if Zone Type can be bypassed.
6 = On if Zone Type is included in the group shunt.
7 = On if Zone Type is force armable.
8 = On if Zone Type is entry guard.