background image

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
NX-148E-CF USERS MANUAL 
NX148ECFUB03   REV B   (MAY2003)
 

Summary of Contents for NetworX NX-148E-CF

Page 1: ...NetworX Series NX 148E CF Commercial Fire LCD Keypad User manual ...

Page 2: ... a trouble condition with your fire system READY light is on when the system is ready to arm flashes if ready to force arm ARMED light is on when armed off when disarmed flashes to indicate a previous alarm NUMERIC CODE ENTRY KEYS PROGRAMMABLE EMERGENCY ACTIVATION KEYS The appropriate stickers should be applied on the keypad door for the Emergency Activation keys that are programmed to work with y...

Page 3: ...Exit Chime Siren Test Forced Arming s s These features should not be enabled on UL listed systems NOTE Some of the features described above may or may not be available for your system Check with your installation company to find out how your system is programmed To Arm or Disarm or Silence Alarm Enter your user code To Quick Arm and Stay Press Stay key To Quick Arm and Exit Press Exit key Door Chi...

Page 4: ......

Page 5: ...e Status 13 Setting The Keypad Tone 13 View Alarm Memory 13 Test Function 13 Display Test Function 14 Light Control For X 10 Devices 14 Change Languages 14 Changing User Codes 15 Assigning User Code Authority Levels 15 Reset Function 16 Reading The Event Log 17 Adjusting The View Brightness Of The LCD 17 Setting The System Clock 18 Using The Door Chime Feature 18 PARTITIONED SYSTEMS OPERATION 19 L...

Page 6: ... system KEEP IN MIND THE LEVEL OF SECURITY YOU WILL OBTAIN WITH THIS SYSTEM RELATES SPECIFICALLY WITH TWO MAJOR FACTORS 1 The quantity quality and placement of security devices attached to this system 2 The knowledge you have of the security system and how that knowledge is utilized in a weekly test of the complete system YOU SHOULD BE AWARE OF THE FOLLOWING FACTS WHEN PREPARING A SAFETY SECURITY ...

Page 7: ...tem that is ready to be force armed will flash the ready light NOTE Those zones that are not ready will not create an alarm Function Code A Function Code is either a four 4 or six 6 digit code that has been programmed by the installer to operate a device Group Bypass An option that allows the user to bypass multiple zones with a single operation Instant Delay An option that allows an instant alarm...

Page 8: ... that the light will flash during the last 10 seconds of the exit delay as a warning that the time is running out The user may want to disarm the system if the exit light is flashing in order to prevent an alarm The user may then re arm the system and exit before the delay expires Fire Light A steady fire light means a fire zone has been faulted A rapidly flashing fire light means that a fire zone...

Page 9: ...tep 2 Enter your 4 or 6 digit user code to arm the system The armed and exit lights will illuminate You may now leave the building IMPORTANT The exit light will flash rapidly for the last 10 seconds of the exit delay as a warning to the user that the exit time is about to expire The user may wish to disarm and rearm the system if more time is needed MAKING YOUR SYSTEM READY TO ARM If the ready lig...

Page 10: ...signated entry exit door If Auto Bypass is enabled omit Step 3 When Auto Instant is enabled if you do not leave through a designated entry exit door the display will read Instant indicating that the entry exit doors no longer have an entry delay If Auto Instant is enabled omit Step 4 Step 3 Press the STAY key The stay light will illuminate indicating that all interior zones are bypassed All interi...

Page 11: ...n armed pressing the EXIT key will start the Exit delay enabling you to leave the building IMPORTANT An alarm will be created if the Instant message is ON at this time and you re enter the building You may re initiate an entry exit delay by pressing the STAY key again The Instant message will disappear DISARMING YOUR SYSTEM When you enter the protected area through one of the designated Entry Exit...

Page 12: ...ore zones this must be done while the system is in the disarmed state If the zone is not known refer to Procedure 2 If you know the number of the zone to bypass use the following Step 1 Press the BYPASS key Step 2 When the LCD prompts for a code optional if programmed enter your user code Step 3 The bypass light flashes Step 4 Enter the zone you wish to bypass Example Press 6 for zone 6 or 1 1 2 f...

Page 13: ...ones will be bypassed Press the BYPASS key again to exit group bypassing UNBYPASSING To manually unbypass zones perform the bypassing procedure on a zone that is already bypassed NOTE All zones will automatically be unbypassed each time the system is disarmed EMERGENCY ACTIVATION KEYS NOTE You must press and hold these keys for 2 seconds to activate these functions Your system may not be programme...

Page 14: ... with your installing company to determine how your security system will respond to the Panic Hold Up activation FUNCTION MENU The functions listed below are found in the Function Menu Step 1 Press r The display will now begin scrolling though a list of functions and the corresponding numbers associated with those functions Step 2 Press the number listed on the display in order to access that part...

Page 15: ...s to set this tone and exit from the Adjust Tone mode VIEW ALARM MEMORY Step 1 Press r 3 to display the zone s on the keypad that created the last alarm Step 2 The LCD Screen will display the zone description for those zones Step 3 Press to exit the alarm memory TEST FUNCTION Optional if programmed If programmed this function will perform a battery test communicator test and or a siren test No ala...

Page 16: ...e X 10 device you want to control The LCD screen will show the light number on the left On the right side of the display it will prompt you to turn the light X 10 device On or Off Step 3 Press the to turn the X 10 device On or press the to turn the X 10 device Off Step 4 The LCD screen will again prompt you to Select Light Number 0 9 Step 5 Repeat Steps 2 and 3 until complete Step 6 Press to exit ...

Page 17: ...u may use the up and down scroll keys to select the digit to change and enter the correct number If it rejects the code because of duplication or such the sounder will beep 3 times Step 5 If another user code needs to be programmed return to step 3 and enter the user code Step 6 Press while the LCD screen is prompting for a new user to exit Code Programming ASSIGNING USER CODE AUTHORITY LEVELS Ass...

Page 18: ...isplay will mark that partition with a hyphen indicating access has been removed If you wish to re establish user access to the partition press the partition number again Step 5 Press r to save the data The LCD will then prompt you for the next user code Step 6 If another user code needs to be programmed return to Step 3 If not press to exit this feature without saving the data RESET FUNCTION This...

Page 19: ...dicates partition Month Day ü Time shown in and r indicates an 24 hour format event not reported This screen shows an opening of Partition 3 on September 25 th at 5 27 p m by user 75 The r shows that this event is not programmed to be reported to the central monitoring station Refer to Appendix A on page 25 for a list of possible log messages ADJUSTING THE VIEW BRIGHTNESS OF THE LCD Step 1 Enter r...

Page 20: ...Step 4 Press the r key to move to the minutes day of week date month and year Step 5 Repeat Steps 3 and 4 until the entire time and date are set USING THE DOOR CHIME FEATURE The door chime is turned on or off by pressing the CHIME key If the chime is on the chime light will be illuminated If the chime is off the chime light will be off Each press of the CHIME key will toggle the chime feature on o...

Page 21: ...re Ready or Force armable FIRE will illuminate if ANY one area has a Fire condition The fire light will flash if ANY area has a Fire Trouble condition POWER will illuminate if the primary power is connected to the NX 8 control panel It will flash if the system has a low standby battery condition STAY will illuminate if ANY area has the stay light on CHIME will illuminate if ANY partition is in the...

Page 22: ...present the areas that are armed Refer to the following table for possible conditions LCD DISPLAY FOR AREA TOP LINE OVER BOTTOM LINE CONDITION Blank Blank Area Not used or Authorized Dash Dash Area Not Ready Flashing Area Dash Area Ready to Force Arm Dash Flashing Area Area Armed Instant Area Dash Area Disarmed Ready to Arm Dash Area Area is Armed To disarm all of these areas press the up scroll k...

Page 23: ...ys and functions entered will affect this individual partition only The lights and display represent the status of that partition only The word System will be replaced with the word Area The following is an example of this feature To exit this screen press Area 5 is selected and Area 5 is ready to arm To exit the individual partition mode enter SILENCING ALARMS IN THE MULTI PARTITION MODE If the k...

Page 24: ...he exit delay Beeps to indicate telephone line fault if selected Beeps during an exit delay beeps rapidly for the last 10 seconds of an exit delay and beeps 1 second at the end of the exit delay Pulses when one or more of the following conditions are detected Zone or Box Tamper Low Battery AC Power Fail or Expander trouble Beeps 3 times every minute indicating a low battery or missing transmitter ...

Page 25: ...ate a message to the Central Station but was unsuccessful Control Ground fault A short to ground has been detected on a control circuit Control Loss of time Your system has lost total power and needs the clock reset Control Low Battery The standby battery is low Control Over current A short circuit of a control s power supply has occurred Control Phone trouble The phone line connected to the contr...

Page 26: ...ouble on the bell or siren circuit Expansion RF Jammed A radio receiver is being jammed Not applicable to all controls Expansion Trouble An expansion device or keypad is not reporting to the control panel Zone Lost Press r A wireless or multiplexed zone device is not reporting to the control Press r to identify the zone Zone Low Batt Press r A wireless device has a low battery Press r to identify ...

Page 27: ...y has occurred Srn Tamp Siren Tamper A siren or speaker tamper has been detected Tel Flt Telephone Fault A telephone fault or tamper has been detected Exp Trb Expansion Trouble An expansion device or keypad is not reporting to the control Log Full Log Full The event log is full Old events will be pushed out as new ones enter the log Open Open Reports user number date time and partition of opening ...

Page 28: ...Test Test has been ended Cross Trip Cross Trip The first zone of a cross zone has been tripped log only Expansion Event Expansion Event An expansion module created an undefined event Partial Arm Partial Arm Reports a closing in the stay mode Listen In Listen In A listen in function has been activated Service Start Service Start Technician is on site Service End Service End Technician is off site C...

Page 29: ...outdoors for a headcount of the building occupants Practice escape procedures In a home sleep with bedroom door closed this will increase your escape time If you suspect fire test the door for heat If you think it is safe brace your shoulder against the door and open it cautiously Be ready to slam the door if smoke or heat rush in Practice escaping to the outdoors and meeting in an assigned spot C...

Page 30: ...SYSTEM NOTES ...

Page 31: ......

Page 32: ...NX 148E CF USERS MANUAL NX148ECFUB03 REV B MAY2003 ...