GE Monogram ZV800 Installation Instructions Manual Download Page 17

17

Installation Instructions

WALL-MOUNTED INSTALLATION—RECIRCULATING

CONNECT ELECTRICAL

Verify that power is turned off at the source.

WARNING:

If house wiring is not 2-wire

with a ground wire, a ground must be provided by 
the installer. When house wiring is aluminum, be sure 
to use U.L. approved anti-oxidant compound and
aluminum-to-copper connectors.

ADVERTISSEMENT

Si la maison n’est pas câblee avec deux fils et un fil 
de terre, l’installateur doit installer un fil de terre. Quand
les fils sont en aluminium, il faut prendre soin d’utiliser
des connecteurs aluminium à cuivre avec une pâte
antioxydante approuvée par U.L.

Remove junction box cover and knockout. 

Use a conduit connector to secure the conduit to 
the junction box.

Connect white leads to branch circuit white lead.

Connect black leads to branch circuit black lead.

Connect green/yellow leads to branch circuit green
lead or bare ground lead.

Secure all connections with wire nuts on each
electrical connector.

Push wires into junction box and replace cover. 
Be sure wires are not pinched.

Secure electrical panel cover with original screws.

6

INSTALL DUCT COVERS

Place the decorative duct
covers on top of the hood.

NOTE: 

The inside piece has 

holes on one end intended for 
use when the hood is installed 
for recirculating purposes. 
Be sure the vented end is at 
the top, the vent holes will 
be visible in this installation.

The inside duct piece must slip 
into the folded ends on the outer
section.

Extend the inner duct piece upwards to the ceiling
mounted air deflector.

Secure the duct cover to the air deflector, driving one
screw on each side.

Locate the screw holes on the bottom outside edge 

of the hood.

Secure the lower duct cover to the hood by installing 
2 screws from the bottom of the hood into the duct
cover.

7

Mounting

screw holes

Vent holes

Install 
2 bottom 
duct cover 
screws

Install 2 screws,

duct cover and

into ceiling

bracket

Summary of Contents for Monogram ZV800

Page 1: ...If you have questions call 800 626 2000 or visit our website at www monogram com Installation Instructions 36 Chimney Vent Hood ZV800 ...

Page 2: ...off at the service panel and lock service panel to prevent power from being switched on accidentally If the service panel cannot be locked fasten a tag or prominent warning label to the panel ADVERTISSEMENT POUR RÉDUIRE LE RISQUE D INCENDIE DE CHOC ÉLECTRIQUE OU DE BLESSURES IL FAUT OBSERVER LES REGLES SUIVANTES A Utiliser cet appareil uniquement de la maniére prévue par le fabricant En cas de que...

Page 3: ...lize Installation 13 Wall Mounted Installation Recirculating Ductwork Wiring Locations 14 Step 1 Install Framing for Hood Support 14 Step 2 Install Mounting Bracket 15 Step 3 Prepare the Hood 15 Step 4 Mount the Hood 16 Step 5 Size and Cut Duct Piece 16 Step 6 Connect Electrical 17 Step 7 Install Duct Covers 17 Step 8 Install Filters 18 Step 9 Finalize Installation 18 Under Cabinet Installation Ca...

Page 4: ...e on site before final framing and wall finishing This will also help to accurately locate the duct work and electrical service POWER SUPPLY IMPORTANT Please read carefully WARNING FOR PERSONAL SAFETY THIS APPLIANCE MUST BE PROPERLY GROUNDED ADVERTISSEMENT POUR DES RAISONS DE SÉCURITÉ CET APPAREIL DOIT ÊTRE CORRECTEMENT MIS À LA TERRE Remove house fuse or open circuit breaker before beginning inst...

Page 5: ...andards such as those published by NFPA and ASHRAE This Hood Must Use a 6 Round Duct It Can Transition To 3 1 4 x 12 Duct 5 Installation Preparation Total Equivalent Quantity Equivalent Duct Piece Dimensions Length Used Length Round 1 ft straight per foot length 3 1 4 x 12 1 ft 3 1 4 x 24 per foot straight length 6 Round 90 elbow 15 ft 6 Round 45 elbow 8 ft 3 1 4 x 12 90 elbow 11 ft 3 1 4 x 12 or ...

Page 6: ...liers Safety glasses Duct tape Tape to mount template Gloves to protect against sharp edges 120V 60Hz 15 or 20 Amp 2 wire with ground Properly grounded branch circuit Strain relief for junction cover 6 round metal duct length to suit installation Saw or jig saw Conduit for house wiring and conduit connector Measuring Tape Electric drill with 1 8 and 3 8 Bits Phillips head screwdriver Safety glasse...

Page 7: ...tion Wall Mount ZV800 Installation Heights Actual Possible Celing Possible VENTED RECIRCULATING Height Installation Height Installation Height 7 11 24 to 27 24 to 25 8 0 24 to 28 24 to 26 8 1 24 to 30 24 to 27 8 2 24 to 30 24 to 28 8 3 24 to 30 24 to 29 8 4 24 to 30 24 to 30 8 5 24 to 30 24 to 30 8 6 24 to 30 24 to 30 8 7 24 to 30 24 to 30 8 8 24 to 30 24 to 30 8 9 24 to 30 24 to 30 8 10 24 to 30 ...

Page 8: ...ps head screws to secure the brackets to the cabinet 8 required 2 extra 49 80270 07 04 JR CUT OUT THIS PORTION C L M O U N T I N G B R A C K E T M O U N T I N G B R A C K E T THIS EDGE AGAINST REAR WALL THIS EDGE AGAINST REAR WALL TOP CABINET TEMPLATE Align template with centerline and tape to bottom of the cabinet 10 13 16 11 3 4 04302127 Cabinet installation template REAR WALL TEMPLATE C L 49 80...

Page 9: ...BE SURE THE TEMPLATE IS LEVEL Ceiling ducting If ductwork will vent straight up to the ceiling Use a level to draw a line straight up from the centerline on the template to the ceiling Measure 3 3 4 from the back wall to the centerline of a 6 1 2 hole on the ceiling NOTE If drywall is not present add drywall thickness to the 3 3 4 dimension Wall Ducting If ductwork will vent to the rear Use a leve...

Page 10: ... Remove the screws Secure the bracket to the ceiling and wall with wood screws and or fasteners 3 INSTALL MOUNTING BRACKET This vent hood must be secured to the horizontal support or wall studs With the template taped in place use a punch to mark all mounting screw locations Drill 1 8 pilot holes at the 6 punched locations Remove the template The 2 holes in the support bracket holes must enter stu...

Page 11: ... top of the hood 4 Remove 2 side cover screws Secure electrical panel with 3 screws Install damper MOUNT THE HOOD Lift the hood onto the mounting bracket Check to be sure it is level Install wood screws through the hood and into the wall on each side of the mounting bracket Extend the canopy forward for better access to the rear mounting screw holes Install 2 wood screws or fasteners through the b...

Page 12: ... green lead or bare ground lead Secure all connections with wire nuts on each electrical connector Push wires into junction box and replace cover Be sure wires are not pinched Secure electrical panel cover with original screws 7 CONNECT DUCTWORK Install ductwork making connections in direction of airflow as illustrated Push duct over the exhaust outlet and damper Secure joints in ductwork with she...

Page 13: ...stalling 2 screws from the bottom of the hood into the duct cover 8 Mounting screws INSTALL FILTERS Remove protective film on the filters Tip the filter into the slots at the rear of the opening Lift the filter lock and pull forward until the filter rests in the slots Install both metal grease filters To remove the filters press inwards on the handle and pull the filter downwards 9 FINALIZE INSTAL...

Page 14: ... 1 8 Pilot Holes Drill 1 8 Pilot Holes Drill 1 8 Pilot Holes Drill 1 8 Pilot Holes ALIGN BOTTOM EDGE WITH PENCIL LINE INDICATING BOTTOM OF THE HOOD 5 1 16 9 5 8 8 1 8 2 1 16 13 3 4 12 3 4 Ceiling WALL MOUNTED INSTALLATION RECIRCULATING INSTALL FRAMING FOR HOOD SUPPORT IMPORTANT Framing must be capable of supporting 100 lbs If drywall is present mark the screw hole locations for the top mounting br...

Page 15: ...ort Check to be sure that the bracket is level There is no way to level the hood after hanging it from this bracket 2 WALL MOUNTED INSTALLATION RECIRCULATING PREPARE THE HOOD Remove the hood from the box Remove packaging and tape Remove one screw on each side of the cover on the electrical panel Lift off the cover and set aside with screws Stand the electrical panel upright Align the screw holes i...

Page 16: ...nto the wall studs Enlarge holes that did not enter studs to 3 8 and tap plastic or metal anchors into the holes flush with the wall Mount the assembly onto the hood outlet push up against the ceiling and install the screws provided CAUTION Do not use sheet metal screws at the hood flange connection Doing so will prevent proper damper operations Seal connection with tape only ATTENTION N utilisez ...

Page 17: ... leads to branch circuit green lead or bare ground lead Secure all connections with wire nuts on each electrical connector Push wires into junction box and replace cover Be sure wires are not pinched Secure electrical panel cover with original screws 6 INSTALL DUCT COVERS Place the decorative duct covers on top of the hood NOTE The inside piece has holes on one end intended for use when the hood i...

Page 18: ...nto the slots at the rear of the opening Lift the filter lock and pull forward until the filter rests in the slots Install both metal grease filters To remove the filters press inwards on the handle and pull the filter downwards 8 FINALIZE INSTALLATION Remove all packaging materials Refer to the Owner s Manual for operating instructions 9 Filter Locks WALL MOUNTED INSTALLATION RECIRCULATING ...

Page 19: ...rk that location Use a level to draw a straight pencil line on the wall Tape the template in position along the penciled line Check to be sure the template is level Use the level to draw a line straight up from the centerline on the template to the ceiling Measure 3 3 4 from the back wall to the centerline of a 6 1 2 hole on the ceiling NOTE If drywall is not present add drywall thickness to the 3...

Page 20: ...the support to secure to wall studs Reinstall drywall 1 Centerline of Installation Space View From Rear Cleats 1 x 6 Min Mounting Support Centerline of installation space View from rear cleats 1 x 6 min mounting support PREPARE THE HOOD Remove the hood from the box Remove packaging and tape Remove one screw on each side of the cover on the electrical panel Lift off the cover and set aside with scr...

Page 21: ...INSTALL WOOD BLOCKS IF NECESSARY Install filler blocks whenever the cabinet frame hangs below the cabinet bottom Install filler blocks whenever the cabinet bottom is less than 3 4 thick Install the filler blocks on each side of the cutout The filler blocks will accept the hood mounting screws NOTE Additional filler blocks may be required along the outside edges to accept the outside screws See Ste...

Page 22: ... this location If there is a noticeable gap between the hood and the bottom of the cabinet on the sides Slide canopy forward and install original top screws through the bottom of the hood and into cabinet bottom or frame NOTE Install wood filler blocks if necessary to accept the screws 7 Install 2 Screws into Each Side Bracket MOUNT THE HOOD Carefully lift the hood into the cabinet Guide the hood ...

Page 23: ... to branch circuit black lead Connect green yellow leads to branch circuit green lead or bare ground lead Secure all connections with wire nuts on each electrical connector Push wires into junction box and replace cover Be sure wires are not pinched Secure electrical panel cover with screws provided 8 INSTALL FILTERS Remove protective film on the filters NOTE It is not necessary to install the cha...

Page 24: ...described in this book safety glasses or goggles should be worn For Monogram local service in your area call 1 800 444 1845 NOTE Product improvement is a continuing endeavor at General Electric Therefore materials appearance and specifications are subject to change without notice ...

Reviews: