2 A
CUTOUT FOR DOUBLE OVENS (2 THERMAL
OVENS)
NOTE:
If the cabinet does not have a front frame and the sides are less than ¾” (1.9 cm) thick,
shim both sides equally to establish the cutout width.
Dim.
Description
30” Double Oven with
Pedestal
30” Double Oven without
Pedestal
A
Cabinet width
30” (76.2 cm)
30” (76.2 cm)
B
Cutout width
28
1
»
2
” (72.4 cm) min.
28
5
»
8
” (72.7 cm) max.
28
1
»
2
” (72.4 cm) min.
28
5
»
8
” (72.7 cm) max.
C
Cutout height
51
13
»
16
” (131.6 cm) min.
51
15
»
16
” (131.9 cm) max.
50 ¼” (127.64cm)
D
Clearance from cutout - side edges*
11
»
16
” (1.75 cm)
11
»
16
” (1.75 cm)
E
Lower door clearance to adjacent corners,
drawers, walls, etc., When door is open
23” (53.3 cm) min.
23” (53.3 cm) min.
F
Clearance from cutout - top*
1” (2.5 cm) min.
(1
1
»
4
” (3.2 cm)
1” (2.5 cm) min.
(1
1
»
4
” (3.2 cm)
G
Clearance from cutout - bottom*
1
1
»
4
” (3.2 cm)
1
1
»
4
” (3.2 cm)
H
Junction box location
9
1
»
2
” (24.1 cm) max.
right side only
9
1
»
2
” (24.1 cm) max.
right side only
J
Height to bottom of junction box
47” (119.4 cm)
47” (119.4 cm)
K
Recommended cutout location from floor
12” (30.5 cm)
12” (30.5 cm)
L
French (upper) door swing depth - Allow additional
clearances for installation and oven usage
16
1
»
4
” (41.3 cm) min.
16
1
»
4
” (41.3 cm) min.
M
Countertop or cabinet door protrusion
(measure if exist)
Measure “M”
Measure “M”
N
Gap between edge of countertop
or cabinet door to cabinet opening
If M = 0, N = 0, Otherwise
N = M + 1” (2.54 cm) min.
If M = 0, N = 0, Otherwise
N = M + 1” (2.54 cm) min.
Continue to Section 3.
H
B
C
K
F
G
D
A
J
E
Junction Box
Location (junction
box may be
located in
adjacent cabinet)
Cutout Depth
23-1/2”
(59.7 cm) Min.
* Refers to minimum clearance required for wall oven installation and does not reflect actual product dimensions.
2 B
CUTOUT FOR INSTALLATION OVER A
WARMING DRAWER
NOTE:
Install the oven only with specific models listed on the label located on top of the oven.
NOTE:
Additional clearances between cutouts may be required. Check to be sure the oven
supports above the Warming Drawer location do not obstruct the required interior depth and height.
When installing a Warming Drawer below a double oven, a separate 120V, 60 HZ, properly
grounded receptacle must be installed. Refer to installation instructions packed with the Warming
Drawer for specific installation requirements.
Anti-Tip Block Against
Rear Wall Per Warming
Drawer Requirement
2" (5.1 cm)
Min.
Per Warming
Drawer
Requirement
C
M
L
L
N