– 52 –
Model JKP75, PK956, & ZEK958
TERMINALS
VOLTAGE
L1-N
120 VAC all the time
N to COM, COM 0,C
120 VAC all the time
L1-1 & 2-Bake 1 & 2
L1-1 & 2-Broil 1 & 2
L1-1 & 2-CONV 1 & 2
240 VAC when oven
is not calling for heat
(BAKE, CONV, and
BROIL relay contacts
open)
*L1 to Con J6 term 1 & 3
120 VAC when light is
on.
L1 to MDL 1 & 2
120 VAC locking or
unlocking.
**L1 to Con J6 term 5 & 6
(See Conv. Fan Assy,)
120 VAC when oven
door is closed and
Conv. Bake, Conv Roast
not operating.
*If the oven light is not working, make the following
checks:
• Check the oven light bulb.
• The
l
ight is to come on when the door is opened
―
check the voltage across the light socket. Terminals
should read 120 VAC. If 0 volts, check the jamb
switch and the wiring.
• The light is to come on when the control light
pad is pressed. K11 or K12 should click. Check the
voltage from N to J6-3 (upper) or N to J6-1 (lower). It
should read 120 VAC. If 0 Volts, check the oven light
keypad using the ohmmeter test. If the keypad is
good, replace the control.
**If the convection fan is not running, make the
following checks:
• Check the voltage from terminal J11 3 to N on the
control
―
it should always read 120 VAC in
Convection Bake
or
Convection Roast
modes. The voltage should
also read 120 VAC when the convection fan is running CCW from terminal J11 1 to N (upper) and J11 5 to N
(lower–when speci
fi
ed) and when the convection fan is running CW from terminal J11 2 to N (upper) and J11
4 to N (lower–when speci
fi
ed).
• If the voltage is OK, check the convection fan motor. It should read approximately 15–20
Ω
at room temp.
Check to make sure the fan shaft is not rubbing on the liner.
• Check the door switch.
• Check the capacitor.
Key Panel Test
Models JKS10, JKP30, & JKP35
Note:
The key panel and the electronic control are a single component.
Press each pad on the key panel followed by the
Clear/Off
pad. If the key panel is functioning properly, the
following should occur:
•
Bake, Broil, Timer, Clock,
and
Cook Time
pads – Audible tone plus display showing mode of operation
selected.
•
Clear/Off
– Audible tone and display shows the time of day.
•
Temp, Hour, Min
pads – No audible tone. Can only be used after another function has been selected.
(
Continued Next Page
)
Summary of Contents for Monogram ZEK938
Page 59: ... 59 Continued Next Page Model JKP30 OVEN TEMP 1100 Ω ROOM TEMP 2650 Ω CLEAN TEMP ...
Page 60: ... 60 Continued Next Page Model JKP35 ...
Page 61: ... 61 Continued Next Page Model JKP55 ...
Page 62: ... 62 Continued Next Page Models JKP70 PK916 ZEK938 ...
Page 63: ... 63 Continued Next Page Models JKP75 PK956 ZEK958 ...
Page 66: ... 66 ...