background image

For answers to your Monogram,

® 

GE Profile

 or 

GE

®

 appliance questions, visit our website at 

ge.com or call GE Answer Center

®

 service,  

800.626.2000.

130553

Specification Created 7/08

Listed by 

Underwriters 

Laboratories

ZDP304NPSS (Natural Gas)

ZDP304LPSS (Liquid Propane)

GE Monogram

® 

30" Dual-Fuel Professional Range with 4 Burners

Dimensions and Installation Information (in inches) 

Optional Backsplash Accessories

The range requires a 12" minimum clearance to a vertical 
combustible surface at the rear. A backsplash is required 
for installations with less than 12" clearance. The following 
backsplash accessories are available, or a custom, non-
combustible backsplash can be used.
Order one with a 30"-wide range backsplash 

ZX12B30PSS–12" backsplash 

ZXADJB30PSS– 30"-36" adjustable-height backsplash with 

warming shelf

Side View with a Backsplash

Electrical Requirements

Ranges must be supplied with 208/240V, 60Hz, and connected 
to an individual, properly grounded branch circuit protected 
by a circuit breaker or time-delay fuse. Install a 30-amp circuit 
for 30" ranges.  
The receptacle must be a NEMA 14-50R device to accept the  
four-prong plug on the range.

Locate gas and  
electric as shown

Gas Supply

•  The natural gas models are designed to 

operate at 5" water column pressure. 
For proper operation, the pressure of 
the natural gas supplied to the regulator 
must be between 7" and 13" water 
column.

•  The LP models are designed to operate 

at 10" water column pressure. For 
proper operation, the pressure of the LP 
gas supplied to the regulator must be 
between 11" and 13" water column.

Universal Utility Locations

Reviews: