ALIGNMENT AND TROUBLESHOOTING PROCEDURES
12
LBI-38438A
5.1.2
TX VCO & RX VCO Alignment
CMC-232A 29.7 - 42 MHz
STEP
METERING
POINT
TUNING
CONTROL
METER
READING
PROCEDURE
1
TP201
Control
Voltage
Monitor
L206
4.0 VDC
7.0 VDC
In case highest transmit frequency is
< 34.0 MHz
. Select lowest frequency
transmit channel. With 50 ohm load on
the antenna connector J1, key the radio.
Monitor TP201 with digital voltmeter
and tune L206 for 4.0 VDC ±0.1 V.
Unkey the radio.
In case the highest transmit
frequency is > 34.0 MHz.
Select
highest frequency transmit channel.
With 50 ohm load on the antenna
connector J1, key the radio. Monitor
TP201 with a digital voltmeter and tune
L206 for 7.0 VDC ±0.1 V. Unkey the
radio.
2
TP201
CV201
7.0 VDC
Select the highest frequency receive
channel. Monitor TP201 with digital
voltmeter and tune CV201 for 7.0 VDC
±0.1 V.
3
TP201
3.5-7.5
VDC
Select lowest frequency channel.
Voltage should be between 3.5 – 7.5
VDC transmit and receive for lowest
and highest frequency channels.
4
J201
+1 to +8
dBm
RX/EX injection level should be
b1 and +8 dBm.
NOTE:
Refer to Figure 5 for location of tuning and adjustment controls.
Figure 5 –
Synthesizer
Tuning and Adjustment Controls
CMC-232B 42 – 50 MHz
Summary of Contents for MLSH041
Page 1: ...LBI 38438A Maintenance Manual Service Section MLS High Band Two Way Mobile Radios MLSH041 ...
Page 10: ...DISASSEMBLY PROCEDURE 10 LBI 38438A Figure 4 Disassembly Procedure Front Panel ...
Page 18: ...ALIGNMENT AND TROUBLESHOOTING PROCEDURES 18 LBI 38438A 5 2 5 Transmitter Troubleshooting ...
Page 19: ...ALIGNMENT AND TROUBLESHOOTING PROCEDURES LBI 38438A 19 ...
Page 24: ...ALIGNMENT AND TROUBLESHOOTING PROCEDURES 24 LBI 38438A 5 3 5 4 Receiver Troubleshooting ...
Page 25: ...ALIGNMENT AND TROUBLESHOOTING PROCEDURES LBI 38438A 25 ...