SD Series Technical Manual
MDS 05-4846A01, Rev. H
Invisible place holder
Figure 24. Basic Setup Wizard
5. At the conclusion of the wizard, click
Done
. Configuration is now
complete for the connected radio. Log out of the
Device Manager
by
clicking
Logout
in the upper right hand side of the screen. If desired,
you may proceed with the additional functions described below.
Using the Remote
Management Wizard
To program the key settings of Remote radios installed in the wireless
network, select
Setup Wizards>>Remote Management
from the AP or Master
Radio
and follow the prompts contained in that tool. At the conclusion
of the wizard, click
Commit Configuration
, followed by
Done
. Remote con-
figuration is now complete.
Getting an Overview
of Radio Settings
To get a top-level view of the key settings and operating parameters for
the radio, select
Overview
and a summary screen will be displayed. When
finished, log out of the
Device Manager
by clicking
Logout
in the upper
right hand side of the screen.
Alternative Management Methods
The following methods are for use where web-based management is not
available:
•
Serial
—(
COM1
DB9 connector). This is the “console terminal”
method of control commonly used on earlier GE MDS radios.
•
Telnet
—(
ETHERNET
RJ-45 connector). Telnet offers essentially
the same capabilities as Serial control, but may be performed
either through a local connection, or over a network.
For more information on alternative management methods, refer to the
SD Serial/Telnet Management Supplement
, Part No. 05-6193A01, avail-
able from the GE MDS website at
www.gemds.com
.