05-6398A01, Rev. C
MDS Master Station Setup Guide
5
Figure 8: COM Connector (RJ-45)
As viewed from outside the unit
Table 5: COM1 Pin-out - Default Data Port
Pin
#
Input/
Output
Pin Description
1
OUT
DSR (Data Set Ready)
2
OUT
DCD (Data Carrier Detect)
3
IN
DTR (Data Terminal Ready)
4
Ground
Connects to chassis ground (negative supply)
5
OUT
RXD (Received Data)
—Supplies received data
to the connected device
6
IN
TXD (Transmitted Data)
—Accepts TX data
from the connected device
7
OUT
CTS (Clear to Send)
8
IN
RTS (Request to Send)
Table 6: COM2 Pin-out - Default Console Port
Pin
#
Input/
Output
Pin Description
1
Reserved
-- (Do not connect)
2
Reserved
-- (Do not connect)
3
Reserved
-- (Do not connect)
4
Ground
Connects to chassis ground (negative supply)
5
OUT
RXD (Received Data)
—Supplies received data
to the connected device
6
IN
TXD (Transmitted Data)
—Accepts TX data
from the connected device
7
OUT
CTS (Clear to Send)
8
IN
RTS (Request to Send)
6.0 ALARM/AUDIO PINOUT
The ALARM/AUDIO Interface on the Alarm/Relay module provides
audio signaling and alarm outputs as shown in Figure
9.
+12v
6
12
Analog RSSI
PTT
5
11
Major Alarm -
Rx Audio -
4
10
Minor Alarm +
Rx Audio +
3
9
Major Alarm -
Tx Audio -
2
8
Minor Alarm +
Tx Audio +
1
7
Ground
Invisible place holder
Figure 9: Alarm/Audio Connections
(As viewed from outside the radio)
7.0 TROUBLESHOOTING
If trouble occurs with the unit, verify that it meets the basic requirements
listed below. These items should be checked prior to starting any de-
tailed troubleshooting or calling for assistance. All units must have:
•
Adequate and stable primary power
•
Secure cable and wiring connections
•
Proper configuration for the application
7.1
LEDs
The LEDs on the front of installed modules (
Table 4: Module LED
Descriptions
) provide useful information when troubleshooting. Power
and alarm indicators are provided on Platform Manager, Radio, and
Alarm/Relay modules. Radio Modules also have TX/RX LEDs to show
wireless activity.
7.2
Redundant Units
The active radio can be identified by the corresponding LED on the
alarm/relay module as well as the active LED on the radio module. The
active unit is normally selected automatically. For troubleshooting, the
toggle switch can be used to manually set the active radio. Alternatively,
the switch can remain in the automatic position and the active radio can
be selected via the Device Manger UI.
7.3
Technical Assistance
Factory technical assistance is available by contacting GE MDS during
business hours (8:30 AM to 6:00 PM Eastern Time). For telephone
assistance, call (585) 241-5510, or visit our website at www.gemds.com
for additional contact options.
Refer also to the
Regulatory & Product Information Sheet
supplied with
these instructions.