![GE MDS 4710M Installation And Operation Manual Download Page 81](http://html2.mh-extra.com/html/ge/mds-4710m/mds-4710m_installation-and-operation-manual_4090481081.webp)
MDS 05-3628A01, Rev. B
MDS 4790M (MPT 1411) I/O Guide
73
RECEIVER SYSTEM
Maximum Usable
Sensitivity
–110 dBm at 10–6 BER
Co-Channel Rejection
–12 dB
Adjacent Channel
Selectivity
Normal Test
Extreme Test
60 dB
50 dB
Spurious Response
Rejection
70 dB
Frequency Range
See Section 2.6,
Model Number Codes
, beginning on
page 6 for model details.
Type
Double conversion superheterodyne
Frequency Stability
±
1.5 ppm
Errors at High Input Levels
+
1 dBm at BER 10-4
Bandwidth
12.5 kHz
PRIMARY POWER
Supply Voltage
100–240 Vac @ 1.4–0.7 A nominal
24 Vdc nominal
48 Vdc nominal
125 Vac to 12 Vdc with external converter
ENVIRONMENTAL
Temperature Range
Full performance: –30 to 60
°
C
Humidity
95% at 40
°
C, non-condensing
Shock and Vibration
Per MIL-810E (shipping)