7 | GE Oil & Gas
© 2015 General Electric Company. All rights reserved.
Ref .
No .
Description
Ref .
No .
Description
Ref .
No .
Description
*1
Clamp
7
Mounting Bracket
14
Cap Screw
*2
Clamp
8
Cap Screw
15
Spring Washer
*3
Machine Screw
9
Back Lever
16
Washer
4
Turnbuckle Screw
10
Clevis
17
Cap Screw
5
Locknut
11
Clip
18
Clamp Rod
6
Turnbuckle
12
Pin
*Used with size 9, 11 and 13 actuators only.
Figure 6
37/38 Spring Diaphragm Actuator
C . 37/38 Diaphragm Actuators
The 496 switch is rigidly mounted on the spring barrel of the
diaphragm actuator by means of a bracket (7) fastened to
the mounting pad with cap screws (8). The back lever (9) is
fastened to the end of the switch shaft with spring washer
(15) and cap screw (17).
The take off linkage must be adjusted before adjusting the
switches. Apply air pressure to the actuator until the actuator
stem has traveled exactly half the rated stroke. Loosen
locknut (5) and turn the turnbuckle (6) until the back lever (9)
is level. Tighten locknut (5) and adjust switches according to
instructions on Page 2.