6
LRX-Series Mounting
Connect conduit end with input leads to existing
junction box and make proper connections. Connect
the black, white, and green/yellow wires of the input
leads to the black, white and green wires using twist-
on wire connectors and close junction box.
Optional dimmer: When connecting with dimming
controller, wires must be run through another
separate knockout hole. Connect the violet (dimming
+) and gray (dimming -) wires to the violet and gray
wires of the fixture.
NOTE:
Please cover dimming leads with wire nuts if
you won’t connect with dimming leads.
Dimming compatibility for both 0-10V and phase cut,
please refer to GE website:
www.gelighting.com/dimming.
AC line
18
0-10 Volt Dimming
Gray
0-10V –
0-10V +
Violet
To 0-10V
Dimmer
LED
Driver
Wiring Diagram
L
D
N
Dimming –
Ground
LRX
Fixture
Black
Violet
White
Gray
Green/Yellow
Lumens Setting Switch
NOTE:
For 1000/650lm and 4000/3000lm, default output lumen is 1000lm and 4000lm respectively. Push switch up or
left to activate 650lm and 3000lm respectively.