Specifications

Maximum Driver Remote Mounting Distance

Input Voltage (VAC)

120 – 277V

Input Power (W)

55W

Input Frequency (Hz)

50/60 Hz

Power Factor

>

0.9

THD

< 20%

Control

0-10V & DALI

Ceilings

Cable Suspension System

Warranty

5 years

Dimensions

47.5 in. x 11.8 in. x 1.38 in. (1206 mm x 299 mm x 35 mm)

Light Fixture Weight

14.3 lbs. (6.5 kg)

Environmental Operating Temperature Range

-10°C to +40°C

Environmental Humidity (non-condensing)

20 to 80% Non-condensing, dry location rated

Environmental Storage Temperature Range

-40°C to +60°C

Supply Wire Gauge

Wire Length*

18 AWG (0.82 mm

2

)

59.0 ft. (18 m)

16 AWG (1.31  mm

2

)

98.4 ft. (30 m)

14 AWG (2.08 mm

2

)

154.2 ft. (47 m)

12 AWG (3.31 mm

2

)

249.3 ft. (76 m)

Conforms to the following standards:

* Includes fixture’s 6.6 ft. (2.0 m) power cord

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause 

harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 

CAN ICES-005 (A) / NMB-005 (A)

Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC 

Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a 

commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in 

accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a 

residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Summary of Contents for Lumination EP24 Series

Page 1: ...rique RISQUES D INCENDIE Respectez tous les codes NEC et codes locaux N utilisez que des fils approuvés par UL ou IEC pour les entrées sorties de connexion Taille minimum 18 AWG 0 82mm2 LuminationTM LED Luminaires Suspended LED Fixture Series EP24 Features Long life 50 000 hour rated life 5 year warranty Dry location rated BEFORE YOU BEGIN Read these instructions completely and carefully Save Thes...

Page 2: ...rd luminaire 4th luminaire 5th luminaire Distance between canopy sets for left and right luminaires 1193mm 47 in Distance between canopy sets for luminaires in the middle 1207mm 47 5 in Example To install five units in series the distance between canopy sets for the 1st left and 5th right luminaire is 1193mm 47 in and the distance between canopy sets for the 2nd 3rd and 4th middle luminaires is 12...

Page 3: ...uminaire to the matching colored wires from the driver enclosure Connect both green wires to the grounding screw Refer to the EP DKIT400UV and EP DKIT400UD LED Driver Installation Instructions for more information Canopy electrical Strain relief bushing Wires from luminaire Suspension cable Cable coupler Stud To driver enclosure To driver enclosure Junction box in ceiling Crossbar 1 Carefully unpa...

Page 4: ...er spring washer and M8 nuts Screw torque should be between 15 3 0 8kg f For multiple units installed in series all canopy sets will have a power cable except the last canopy Optional Mounting Method Connecting Suspended Fixtures in Series Reattach suspension wire to Y shape suspension wire To adjust height and to level a fixture squeeze the tip of the gripper and pull the suspension cable to the ...

Page 5: ...re Length 18 AWG 0 82 mm2 59 0 ft 18 m 16 AWG 1 31 mm2 98 4 ft 30 m 14 AWG 2 08 mm2 154 2 ft 47 m 12 AWG 3 31 mm2 249 3 ft 76 m Conforms to the following standards Includes fixture s 6 6 ft 2 0 m power cord This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interf...

Reviews: