GE JVX5360 Owner'S Manual & Installation Instructions Download Page 9

49-2001095   Rev. 0

9

Installation 
Instructions

INST

ALLA

TION INSTRUCTIONS

BEFORE YOU BEGIN

Read these instructions completely and 
carefully.

• 

 

IMPORTANT

 — 

Save these 

instructions for local inspector’s use.

 

 

IMPORTANT

 —

 Observe all governing 

codes and ordinances.

   Note to Installer 

– Be sure to leave these 

instructions with the Consumer.

•  

Note to Consumer 

– Keep these instructions for 

future reference.

• 

 Skill level 

– Installation of this vent hood requires 

basic mechanical and electrical skills.

•  

Proper installation is the responsibility of the 
installer. 

•  

Product failure due to improper installation is not 
covered under the Warranty.

FOR YOUR SAFETY

WARNING

 Before beginning the installation, 

switch power off at service panel and lock the 
service disconnecting means to prevent power from 
being switched on accidentally. When the service 
disconnecting means cannot be locked, securely 
fasten a prominent warning device, such as a tag, 
to the service panel.

CAUTION

 To reduce risk of fire and to 

properly exhaust air, be sure to duct air outside. 
Do not vent exhaust air into spaces within walls or 
ceilings or into attics, crawl spaces or garages.

WARNING

 Disconnect all electrical power 

at the main circuit breaker or fuse box before 
installing.

Under the Cabinet (UTC) Hoods

JVX3240, JVX3300, JVX5300, JVX5360, JVX5305, 
JVX5365, PVX7300, PVX7360

WARNING

 TO REDUCE THE RISK OF FIRE, 

ELECTRIC SHOCK OR INJURY TO PERSONS, 
OBSERVE THE FOLLOWING:

A.  Installation work and electrical wiring must be 

done by qualified person(s) in accordance with 
all applicable codes and standards, including 
fire-rated construction.

B.  Sufficient air is needed for proper combustion 

and exhausting of gases through the flue 
(chimney) of fuel burning equipment to prevent 
back drafting. Follow the heating equipment 
manufacturer’s guidelines and safety standards 
such as those published by the National Fire 
Protection Association (NFPA), the American 
Society for Heating, Refrigeration and Air 
Conditioning Engineers (ASHRAE) and the local 
code authorities. 

C.  When cutting or drilling into wall or ceiling, do 

not damage electrical wiring and other hidden 
utilities.

D.  Ducted fans must always be vented to the 

outdoors.

WARNING

 

TO REDUCE THE RISK OF FIRE, 

USE ONLY METAL DUCT WORK.

 

  “If you have questions, call GE Appliances at 800.GE.CARES (800.432.2737) 

or visit our website at: GEAppliances.com”

OPTIONAL POWER CORD KIT 
JXHC1

An optional power cord kit, model JXHC1, is 
available at extra cost from your GE Appliances 
supplier for installation using a standard 3-prong, 
grounded wall outlet. Follow the installation 
instructions packed with the kit to connect the 
power cord to the range hood. 

Summary of Contents for JVX5360

Page 1: ...nces com RANGE HOODS 49 2001095 04 22 GEA SAFETY INFORMATION 3 USING THE HOOD Controls 5 Chef Connect 6 CARE AND CLEANING Filters 7 Surfaces 8 Lights 8 INSTALLATION INSTRUCTIONS 9 TROUBLESHOOTING TIPS...

Page 2: ...s into every GE Appliances product and we think you will too Among other things registration of your appliance ensures that we can deliver important product information and warranty details when you n...

Page 3: ...en cooking at high heat or when flamb ing food i e Crepes Suzette Cherries Jubilee Peppercorn Beef Flanb C Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter...

Page 4: ...ly with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to a provide reasonable protection against harmful interference in a residential installa...

Page 5: ...onds to activate auto off after 15 minutes 4 Fan Settings Buttons Speed control for fan Press the button Lo for LOW speed Med for MEDIUM speed and Hi for HIGH speed Hold down the Hi button for 3 secon...

Page 6: ...the hood press and hold the Light pad for 3 seconds The backlight for the Lo Med Hi Light will flash in that sequence until the hood is paired with the range or other device If the pairing is successf...

Page 7: ...isposable charcoal filter that helps remove smoke and odors NOTE DO NOT rinse or put charcoal filter in an automatic dishwasher The charcoal filter cannot be cleaned It must be replaced It is recommen...

Page 8: ...aces About one tablespoon of ammonia may be added to the water Use a clean hot damp cloth to remove soap Dry with a dry clean cloth NOTE When cleaning take care not to come in contact with filters and...

Page 9: ...ore installing Under the Cabinet UTC Hoods JVX3240 JVX3300 JVX5300 JVX5360 JVX5305 JVX5365 PVX7300 PVX7360 WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING...

Page 10: ...length The ducting from this fan to the outside of the building has a strong effect on the air flow noise and energy use of the fan Use the shortest straightest duct routing possible for best perform...

Page 11: ...od This hood must be installed onto a cabinet It can be vented to the outdoors or it can be installed for recirculating operation Bottom edge of cabinet needs to be 30 or more from the cooking surface...

Page 12: ...duce risk of fire and to properly exhaust air be sure to duct the air outside Do not vent exhaust air into spaces within walls or ceilings or into attics crawl spaces or garages PARTS SUPPLIED FOR INS...

Page 13: ...s 4 E Screws 10 HARDWARE COMPONENTS The hood is designed to fit 12 deep cabinets For 15 deep cabinets filler panel kits are available from GEApplianceParts com JXS50SS for 30 wide hoods JXS56SS for 36...

Page 14: ...lified electrician or service representative if you are in doubt whether the appliance is properly grounded ADVANCE PLANNING Vented Install Planning This hood is designed to be vented vertically using...

Page 15: ...y be needed for cabinets with a recessed bottom Skip to step B A To install the mounting bracket Drive E screws in partway into mounting bracket The bracket labeled R will be used on the right side of...

Page 16: ...Round Use the diagram as a template and mark the locations on the cabinet for ductwork and electrical wiring C Outside rear exhaust Horizontal duct 3 1 4 x 10 Rectangular Use the diagram as a templat...

Page 17: ...s NOTE For an ENERGY STAR model unit must be vented mode to be considered ENERGY STAR certified 7 ATTACH DAMPER DUCT CONNECTOR Attach damper duct connector over knockout opening with two or four D scr...

Page 18: ...Some Models Install with vented mode deflector part On Some Models The existing deflector part must be removed To remove the existing deflector piece unscrew to remove it Install the vented mode defl...

Page 19: ...nting screw 4 12 CONNECT DUCTWORK TO HOOD Ducted installations only Connect ducting to hood Use duct tape to make joints secure and airtight INSTALLATION INSTRUCTIONS Installation Instructions 13 ELEC...

Page 20: ...Some Models 1 For recirculation Install the charcoal filter 2 For ducted installation Install the grease filters On Some Models 1 For recirculation Place the charcoal filter not included in place and...

Page 21: ...d or fan is making loud or abnormal airflow noise Obstructions in duct work Make sure nothing is blocking the vent Make sure your wall or roof cap has a blade or door Damper blade on wall or roof cap...

Page 22: ...iances Vented Range Hood Warranty EXCLUSION OF IMPLIED WARRANTIES Your sole and exclusive remedy is product repair as provided in this Limited Warranty Any implied warranties including the implied war...

Page 23: ...er to the Consumer Support page for phone numbers and website information The following products and more are available Accessories Parts Charcoal Filter Remote Control Replacement Lights 15 Cabinet F...

Page 24: ...e while your warranty is still in effect You can purchase it on line anytime GE Appliances Services will still be there after your warranty expires In the US GEAppliances com extended warranty or call...

Page 25: ...LA PLACA DE COCCI N Controles 5 Chef Connect 6 CUIDADO Y LIMPIEZA Filtros 7 Superficies 8 L mparas 8 INSTRUCCIONES DE INSTALACI N 9 CONSEJOS PARA LA SOLUCI N DE PROBLEMAS 21 GARANT A LIMITADA 22 ACCE...

Page 26: ...y creemos que usted tambi n Entre otras cosas el registro de su electrodom stico asegura que podamos entregarle informaci n importante del producto y detalles de la garant a cuando los necesite Regis...

Page 27: ...N la campana cuando cocine con configuraciones elevadas o cuando flambee alimentos por ej Crepes Suzette cerezas Jubilee carne flambeada a la pimienta en grano C Limpie los ventiladores con frecuencia...

Page 28: ...ampana fue probado y cumple con los l mites establecidos para un dispositivo digital de Clase B de acuerdo con la parte 15 de las Normativas de la FCC Estos l mites fueron dise ados para a brindar una...

Page 29: ...segundos para activar la funci n de apagado autom tico luego de 15 minutos 4 Botones de la Configuraci n del Ventilador Control de velocidad del ventilador Presione el bot n de Lo para activar la vel...

Page 30: ...vo Para iniciar el proceso de emparejamiento de la campana mantenga presionada la tecla Light Luz durante 3 segundos La luz trasera Lo Baja Med Media Hi Alta Light Luz titilar en esa secuencia hasta q...

Page 31: ...scartable que ayude a retirar el humo y los olores NOTA NO enjuague o coloque el filtro de carb n en el lavavajillas autom tico El filtro de carb n no puede ser limpiado Debe ser reemplazado Se recomi...

Page 32: ...a de la Luz Superficies de acero inoxidable en algunos modelos No utilice almohadillas de acero porque rayan la superficie Para limpiar la superficie de acero inoxidable utilice agua tibia jabonosa o...

Page 33: ...de acuerdo con todos los c digos y est ndares aplicables incluyendo construcciones resistentes al fuego B Es necesario contar con suficiente cantidad de aire para una combusti n y salida de gases adec...

Page 34: ...Conexi n del escape Esta campana fue dise ada para ser ventilada de forma vertical usando un conducto redondeado de 7 o un conducto rectangular de 3 1 4 x 10 o de forma horizontal usando un conducto r...

Page 35: ...el gabinete Puede contar con ventilaci n hacia el exterior o puede ser instalada para un funcionamiento con recirculaci n El extremo inferior del gabinete debe estar a una distancia de 30 o m s desde...

Page 36: ...alida hacia espacios dentro de paredes o cielorrasos o ticos espacios muy bajos o garajes PIEZAS PROVISTAS PARA LA INSTALACI N 1 Paquete de Herramientas 1 Paquete Escrito 1 Pieza Deflectora del Modo d...

Page 37: ...REPARACI N PARA LA INSTALACI N Preparaci n para la instalaci n COMPONENTES DE LA CAMPANA EXTRACTORA A Cuerpo de la Campana B Regulador Conector del Conducto C Soporte del Montaje D Tornillos 4 E Torni...

Page 38: ...te La ubicaci n de la conexi n del suministro de corriente es indicada en la secci n de Preparaci n El ctrica y de la Ventilaci n en la p gina 15 SUMINISTRO DE ENERG A IMPORTANTE Tenga a bien leer cui...

Page 39: ...del gabinete Es posible que sean necesarias cu as de madera para gabinetes con la parte inferior empotrada Avance al paso B A Para instalar el soporte de montaje Coloque los tornillos E hasta la mita...

Page 40: ...lla y marque las ubicaciones del gabinete para el conducto y el cableado el ctrico C Escape posterior exterior ducto horizontal rectangular 3 1 4 x 10 Use el diagrama como plantilla y marque las ubica...

Page 41: ...camente Salida vertical rectangular de 3 1 4 Destape el orificio ciego del ducto rectangular nicamente 7 ADHERENCIA DEL REGULADOR CONECTOR DEL CONDUCTO Adhiera el regulador conector del conducto a la...

Page 42: ...la pieza del deflector del modo de ventilaci n En Algunos Modelos La pieza existente del deflector debe ser eliminada A fin de retirar la pieza deflectora existente destornille la misma Instale la pi...

Page 43: ...ciones de instalaci n 13 CONEXI N EL CTRICA 1 Conecte el Cable de Suministro de Corriente a la campana extractora Conecte el conductor blanco del suministro de corriente al conductor blanco de la camp...

Page 44: ...circulaci n Instale el filtro de carb n 2 Para la instalaci n con conducto Instale los filtros de grasa En Algunos Modelos 1 Para la recirculaci n Coloque el filtro de carb n no incluido en su posici...

Page 45: ...si lo hubiera pueden estar sucios Aseg rese de que el regulador de tiro se mueva libremente Las hojas del regulador de tiro pueden darse vuelta y no se abrir n por completo cuando esto suceda Aj stel...

Page 46: ...HO VHUYLFLR WpFQLFR SDUD UHSDUDU R UHHPSOD DU ODV l mparas excepto las l mparas LED GARANT A LIMITADA Garant a limitada de la Cocina El ctrica de GE Appliances EXCLUSI N DE GARANT AS IMPL CITAS Su nic...

Page 47: ...s Web consulte la p gina de Soporte para el Consumidor Estos y otros productos est n disponibles Accesorios Piezas Filtro de Carb n Control Remoto L mparas de Reemplazo Panel del Gabinete de Relleno d...

Page 48: ...ant a a n est vigente La puede adquirir en cualquier momento a trav s de Internet Los servicios de GE Appliances a n estar n all cuando su garant a caduque En EE UU GEAppliances com extended warranty...

Reviews: