GE JVB37 Owner'S Manual & Installation Instructions Download Page 9

9

Installation Instructions

Base

cabinet

INSTALLATION POSSIBILITIES

When the kitchen design calls for an against
the wall installation, move 24

deep base

cabinet forward, 3

to 5

. Filler panels can 

be angled or flat to fill the space between
adjacent cabinets.

Maintain cutout clearances to front edge as specified.

In an island or peninsula, the countertop can 
be extra deep to provide seating opposite of
the cooktop. Adding base cabinets on each 
side of the cooktop provides extra storage 
and countertop work space.

Filler

panel

Filler

panel

Base sink
30

Min. for JVB37 and JVB94

36

Min. for JVB67 and JVB98

18

Base to sink 

30

to 42

Cover

panel

Countertop
overhang 
per cooktop
clearances
must be
maintained

End

panel

18

Summary of Contents for JVB37

Page 1: ...op 4 Using the Downdraft System 4 Care and Cleaning Grease Filters 5 Painted or Metal Surfaces 5 Stainless Steel Surfaces 5 Installation Instructions Advance Planning 8 9 Before You Begin 6 30 Cooktop Downdraft Units JVB37 and JVB94 10 36 Cooktop Downdraft Units JVB67 and JVB98 11 Dimensions and Clearances 7 8 Ductwork 8 13 15 Electrical and Gas Location 8 Installation Possibilities 9 Installing t...

Page 2: ...ng device such as a tag to the service panel C Do not use this unit with any solid state speed control device D This unit must be grounded CAUTION For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors CAUTION To reduce risk of fire and to properly exhaust air be sure to duct air outside Do not vent exhaust air into spaces within walls or ceilings or int...

Page 3: ...ware appropriate for the size of the surface element WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING A Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction B Sufficient air is needed for proper combustion and exhausting of gases through the flue...

Page 4: ... of the switch and hold until you observe the vent moving then release The air vent will rise Use the selector switch to turn the blower ON OFF or to change the blower speed The vent may be lowered by again pressing the raise lower switch at the top right side of the vent The blower if left on will automatically go off when the vent is lowered NOTE For most convenient operation set the blower to t...

Page 5: ...urners Canning When canning foods in a water bath canner a gentle but steady boil must be maintained continuously for the required time When canning foods in a pressure canner the pressure must be maintained continuously for the required time Use of the blower at HIGH speed when canning may reduce the temperature enough to stop boiling While canning we recommend using the downdraft at LOW speed an...

Page 6: ...ocal inspector s use IMPORTANT Observe all governing codes and ordinances Note to Installer Be sure to leave these instructions with the Consumer Note to Consumer Keep these instructions for future reference Note This appliance must be properly grounded Proper installation is the responsibility of the installer Product failure due to improper installation is not covered under the Warranty TOOLS YO...

Page 7: ...wall or ceiling do not damage electrical wiring and other hidden utilities WARNING To reduce the risk of fire use only metal ductwork C B A IMPORTANT These vents are recommended for island installations Against the wall installations are limited due to countertop depth requirements The vent and cooktop combined depth requires an extra deep flat countertop surface The countertop must be at least 26...

Page 8: ...d placing cabinetry directly above the cooking surface when possible If cabinetry is used above the cooking surface Installation must conform with local codes Use cabinets no more than 13 deep Maintain 30 minimum clearance between cooktop and unprotected cabinets directly above cooktop If clearance is less than 30 protect cabinet bottoms with flame retardant millboard at least 1 4 thick or gypsum ...

Page 9: ... Maintain cutout clearances to front edge as specified In an island or peninsula the countertop can be extra deep to provide seating opposite of the cooktop Adding base cabinets on each side of the cooktop provides extra storage and countertop work space Filler panel Filler panel Base sink 30 Min for JVB37 and JVB94 36 Min for JVB67 and JVB98 18 Base to sink 30 to 42 Cover panel Countertop overhan...

Page 10: ...ides of the opening are parallel and rear and front cuts are exactly perpendicular right angle to sides Model Combined Number Cutout Depth JP340 JP346 JP355 JP356 JP910 JP930 JP940 JP950 22 1 4 PP912 PP932 PP942 PP945 PP950 JGP337 JGP940 JP328 JGP328 JGP330 22 3 8 JGP933 JGP945 Includes 1 8 gap between cooktop and vent trim Required to maintain UL or CSA approvals 10 Installation Instructions INST...

Page 11: ... follow as a cutting guide Make sure sides of the opening are parallel and rear and front cuts are exactly perpendicular to sides 11 Installation Instructions 21 8 81 2 36 21 2 Minimum 34 See table Model Combined Number Cutout Depth JP626 21 1 8 JP655 JP960 JP970 JP980 PP962 21 3 4 PP972 PP975 PP980 JGP970 JGP628 JGP630 JGP637 21 7 8 JGP963 JGP975 Includes 1 8 gap between cooktop and vent trim Req...

Page 12: ...ctric cooktop the vent must operate from a separate 120V outlet A properly grounded 3 prong receptacle should be located within reach of the vent s 2 foot power cord Locate the receptacle inside the cabinet on the right side wall The receptacle cannot be placed on the back of the cabinet wall where it may interfere with the downdraft plenum See illustration NOTE Do not use an extension cord or ada...

Page 13: ...ct Equivalent Pieces Length Pieces Length Pieces Length 31 4 x 10 to 6 Round 6 Round 1 ft per 31 4 x 10 Transition 4 ft Straight foot length 45 Elbow 8 ft 90 Elbow 6 Round 31 4 x 10 1 ft per 31 4 x 10 Wall Cap 24 ft Straight foot length 90 Flat Elbow 33 ft with Damper 6 Round 31 4 x 10 6 12 ft to 31 4 x 10 2 ft Wall Cap 24 ft 90 Elbow Transition with Damper 31 4 x 10 6 to 6 Round 2 ft 6 Round 45 E...

Page 14: ...ing plate assembly Retain screws Remove the blower assembly turn it over to access the 4 nuts holding the blower to the mounting plate Remove the nuts IMPORTANT Do not lift the motor by the power cable Turn the blower to the left or right discharge direction and reinstall the 4 nuts Reinstall the blower and mounting plate with original screws To Locate the Ductwork Holes in the Cabinet Floor or Si...

Page 15: ...owndraft unit slots INTO the next piece of the duct Secure the joints with self tapping screws and apply duct tape around the joints to ensure an airtight seal 2 INSTALL THE DOWNDRAFT VENT Place the downdraft vent into the countertop cutout against the back side Secure the downdraft to the countertop supplied brackets See illustration Fasten 2 brackets to vent side and secure to cabinet back wall ...

Page 16: ...lead through the mounting bracket and countertop Press trim over the mounting bracket to set the adhesive Connect Raise Lower Wire Lead to Wire Box Thread wire end with the connector through the hole on the end of a wire box Pull approximately 3 additional wire length beyond the open end of the box Connect the mating wire connectors Install the wire box onto the bottom of the countertop or directl...

Page 17: ...y touches the front edge of the downdraft cover Using a dime as a thickness gauge align the cooktop so that there is a minimum uniform gap of 0 05 the thickness of a dime between the cooktop and the downdraft cover NOTE Do not force the downdraft cover to move rearward when aligning the cooktop This may cause the downdraft cover to impact and damage the cooktop when the vent is raised and lowered ...

Page 18: ... extended Press the Raise Lower switch The blower control switch Slide it to the right may be in the OFF position Vent does not rise Vent not plugged into an outlet Plug vent into a 120V power outlet Raise Lower switch did not Hold switch down for a couple of seconds to engage lift motor activate motor Circuit breaker may have Check circuit breaker Reset if necessary tripped Remote switch not plug...

Page 19: ...so have other rights which vary from state to state To know what your legal rights are consult your local or state consumer affairs office or your state s Attorney General If you have an installation problem contact your dealer or installer You are responsible for providing adequate electrical gas exhausting and other connecting facilities as described in the Installation Instructions provided wit...

Page 20: ...unts that are available while your warranty is still in effect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consumer Home Services will still be there after your warranty expires Parts and Accessories ge com Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes VISA MasterCard and Discover cards ...

Page 21: ...pieza Filtros para grasa 5 Superficies de acero inoxidable 5 Superficies pintadas o metálicas 5 Instrucciones de instalación Antes de empezar 6 Conductos 8 13 15 Dimensiones y espacios 7 8 Instalación del sistema de ventilación descendente 10 17 Interruptor Raise Lower subir bajar 16 Kits opcionales 17 Opciones de ventilación 14 Planificación anticipada 8 9 Posibilidades de instalación 9 Suministr...

Page 22: ... panel de servicio C No use esta unidad con ningún dispositivo de control de velocidad de estado sólido D Esta unidad debe estar conectada a tierra PRECAUCIÓN Úsese para fines de ventilación general únicamente No lo utilice para ventilar materiales peligrosos o explosivos y vapores PRECAUCIÓN A fin de reducir el riesgo de incendio y de extraer el aire adecuadamente asegúrese de que el aire tenga s...

Page 23: ...iempre use batería de cocina apropiada para el tamaño del elemento de la superficie ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIO CHOQUE ELÉCTRICO O LESIONES PERSONALES OBSERVE LO SIGUIENTE A El trabajo de instalación y de cableado eléctrico lo debe realizar una persona calificada de acuerdo con todos los códigos y normas correspondientes incluyendo una construcción calificada contra incendios B ...

Page 24: ...or y sostenga hasta que observe la unidad está en movimiento luego libere El sistema de ventilación de aire se levantará Use el interruptor selector para encender ON apagar OFF o cambiar la velocidad del ventilador Para bajar el aparato presione nuevamente el interruptor Raise Lower en la parte superior derecha Si se deja encendido el ventilador se apagará automáticamente cuando se baje la unidad ...

Page 25: ...rvas Al preparar conservas de alimentos en una olla de preparación de conservas canner con baño de agua se debe mantener un hervor leve pero constante por el tiempo necesario Al preparar conservas en una olla de preparación de conservas a presión la presión se debe mantener continuamente por el tiempo necesario El uso del ventilador en la velocidad alta HIGH al preparar conservas puede reducir la ...

Page 26: ...os y ordenanzas vigentes Nota para el instalador Cerciórese de dejar estas instrucciones en poder del consumidor Nota para el consumidor Mantenga estas instrucciones para referencia futura Nota Es necesario conectar este aparato a tierra correctamente La instalación apropiada es responsabilidad del instalador La falla del producto debido a una instalación incorrecta no está cubierta por la garantí...

Page 27: ...otros cables ocultos de servicios públicos ADVERTENCIA Para reducir el riesgo de incendio use únicamente conductos de metal C B A IMPORTANTE Este sistema de ventilación está recomendado para la instalación de estufas tipo isla Las instalaciones contra la pared están limitadas debido a los requisitos de profundidad de la encimera La profundidad combinada del sistema de ventilación y la estufa requi...

Page 28: ...ible evite colocar gabinetes directamente encima de la superficie de la estufa Si usa gabinetes encima de la superficie de la estufa La instalación debe cumplir con los códigos locales Use gabinetes no superiores a 13 de profundidad Mantenga un espacio mínimo de 30 entre la estufa y los gabinetes no protegidos directamente encima de la estufa Si el espacio es inferior a 30 proteja el fondo de los ...

Page 29: ...a forma especificada En un diseño tipo isla o península la encimera puede tener profundidad adicional para ofrecer la posibilidad de sentarse frente a la estufa Agregar gabinetes de base en cada lado de la encimera ofrece almacenamiento adicional y espacio de trabajo en la encimera 9 Instrucciones de instalación Gabinete base Panel de relleno Panel de relleno Módulo base 30 min para JVB37 y JVB94 ...

Page 30: ... encimera para seguirlas como una guía de corte Cerciórese de que los costados de la abertura estén paralelos y los cortes traseros y delanteros sean exactamente perpendiculares alguno derecho a los costados 21 8 81 2 30 21 2 Mín 281 2 Consulte la tabla No de Profundidad de modelo corte combinada JP340 JP346 JP355 JP356 JP910 JP930 JP940 JP950 22 1 4 PP912 PP932 PP942 PP945 PP950 JGP337 JGP940 JP3...

Page 31: ... corte Cerciórese de que los costados de la abertura estén paralelos y los cortes traseros y delanteros sean exactamente perpendiculares a los costados 11 Instrucciones de instalación 21 8 81 2 36 21 2 Mín 34 Consulte la tabla No de Profundidad de modelo corte combinada JP626 21 1 8 JP655 JP960 JP970 JP980 PP962 21 3 4 PP972 PP975 PP980 JGP970 JGP628 JGP630 JGP637 21 7 8 JGP963 JGP975 Incluye un e...

Page 32: ...tilador se debe operar en una tomacorriente independiente de 120V Se debe ubicar un tomacorriente de tres patas correctamente conectado a tierra dentro del alcance del cable eléctrico de 2 pies de la unidad del ventilador Coloque el tomacorriente al interior del gabinete en la pared derecha El tomacorriente no se debe colocar en la parte trasera de la pared del gabinete donde pueda interferir con ...

Page 33: ... 8 cm x 25 cm 2 4 ms hasta 6 15 cm 1 2 ms Tapa de pared Tubo recto 1 pie 30 cm Codo plano de circular de 6 de 31 4 x 10 por longitud 90 de 31 4 x 10 33 pies 15 cm con 24 pies 8 cm x 25 cm en pies 8 cm x 25 cm 10 1 ms regulador de tiro 7 3 ms Tapa de pared Transición circular con regulador de Codo de 90 12 pies de 6 15 cm hasta 2 pies tiro de 31 4 x 10 24 pies de 6 15 cm 3 7 ms 31 4 x 10 8 cm x 25 ...

Page 34: ...tornillos Retire la ensambladura del ventilador voltéela para tener acceso a las 4 tuercas que sostienen el ventilador con el plato de montaje Retire las tuercas IMPORTANTE No levante el motor por el cable eléctrico Gire el ventilador hacia la dirección de descarga izquierda o derecha y vuelva a instalar las 4 tuercas Vuelva a instalar el ventilador y el plato de montaje con los tornillos original...

Page 35: ...s empates con tornillos auto enrroscantes y aplique cinta de conductos alrededor de los empates para garantizar un sellamiento hermético 2 INSTALE EL VENTILADOR DE TIRO DESCENDENTE Coloque el ventilador de tiro descendente en el corte de la encimera contra el lado posterior Asegure la unidad de tiro descendente a los soportes de la encimera suministrados Consulte la ilustración Asegure dos soporte...

Page 36: ...rte de montaje y la encimera Presione la montura sobre el soporte de montaje para fijar el adhesivo Conecte el cable del interruptor Raise Lower a la caja de cables Pase el extremo del cable con el conector a través del orificio en el extremo de una caja de cables Hale aproximadamente 3 de longitud adicional de cable más allá del extremo abierto de la caja Conecte los conectores de cable correspon...

Page 37: ...ntero de la tapa del sistema de tiro descendente Con una moneda para medir el espesor alinee la estufa de manera que haya un espacio mínimo uniforme de 0 05 el espesor de una moneda de 10 centavos entre la estufa y la tapa del sistema de tiro descendente NOTA No fuerce la tapa del sistema de tiro descendente para moverse hacia atrás al alinear la estufa Esto puede causar que la tapa se impacte y d...

Page 38: ...Deslícelo a la derecha del ventilador puede estar la posición de apagado OFF La unidad no se levanta La unidad no está conectada Conecte la unidad a una tomacorriente de 120V a la corriente El interruptor Raise Lower no Presione el interruptor por un par de segundos para activó el motor que levanta la activar el motor unidad Es posible que el interruptor de Revise el interruptor de circuitos Vuelv...

Page 39: ... conocer sus derechos legales consulte con su oficina local o estatal de asuntos del consumidor o con el procurador general de su estado Si tiene un problema con la instalación póngase en contacto con su concesionario o instalador Usted es responsable de ofrecer las instalaciones adecuadas eléctricas de gas escape y cualquier otra conexión como se describe en las instrucciones de instalación entre...

Page 40: ... su garantía está aún activa Puede comprarla en línea en cualquier momento o llamar al 800 626 2224 durante horas normales de oficina GE Consumer Home Services estará aún ahí cuando su garantía termine Piezas y accesorios ge com Aquellos individuos con la calificación necesaria para reparar sus propios electrodomésticos pueden pedir que se les manden las piezas o accesorios directamente a sus hoga...

Reviews: