• For Personal Safety, remove house fuse

or open circuit breaker before beginning
installation. Failure to do so could result
in serious injury or death.

• Be sure your cooktop is installed properly

by a qualified installer or service technician.

• To eliminate the risk of burns or fire due

to reaching over heated surface elements,
cabinet storage located above the surface
units should be avoided. If cabinet storage
space is to be provided, the risk can be
reduced by installing a range hood that
projects horizontally a minimum of 5"
beyond the bottom of the cabinets. Cabinet
installation above the cooktop may be no
deeper than 13."

• Make sure the cabinets and wall coverings

around the cooktop can withstand the
temperatures (up to 200°F) generated
by the cooktop.

• The cooktop should be easy to reach and

lighted with natural light during the day.

• Always disconnect the electrical service to

the cooktop before repairing or servicing
the cooktop. This can be done by
disconnecting the fuse or circuit breaker.
Failure to do this could result in a
dangerous or fatal shock. Know where your
main disconnect switch is located. If you do
not know, have your electrician show you.

2

Installation Instructions

IMPORTANT SAFETY INSTRUCTIONS

This appliance must be supplied with
the proper voltage and frequency, and
connected to an individual, properly
grounded branch circuit, protected by a
circuit breaker or a time delay fuse as
noted on rating plate.
We recommend you have the electrical
wiring and hookup of your cooktop
connected by a qualified electrician. After
installation, have the electrician show you
where your main cooktop disconnect
is located.
Wiring must conform to National Electrical
Code. You can get a copy of the National
Electrical Code, ANSI/NFPA No. 70-Latest
Edition, by writing:

National Fire Protection Association

Batterymarch Park

Quincy, MA  02269

The cooktop conduit wiring is approved for
copper wire connection only. If you have
aluminum house wiring, you must use
special UL approved connectors for joining
copper to aluminum.
You must use a two-wire, three conductor
208/240 VAC, 60 Hertz electrical system.
A white (neutral) wire is not needed for this
unit. The cooktop must be installed in a
circuit that does not exceed 125 VAC
nominal to ground.
Refer to the rating plate on your cooktop
for the KW rating for your cooktop.

Electrical
Requirements

For Your Safety

Summary of Contents for JP961

Page 1: ...tructions for future reference Note This appliance must be properly grounded Parts Included 1 8 Drill Bit Electric or Hand Drill Phillips Head Screwdriver Pencil Ruler or Straightedge Wire Nuts Saber...

Page 2: ...disconnect switch is located If you do not know have your electrician show you 2 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS This appliance must be supplied with the proper voltage and fre...

Page 3: ...tructions completely and carefully IMPORTANT Save these instructions for local inspector s use IMPORTANT OBSERVE ALL GOVERNING CODES AND ORDIANCES Note to Installer Be sure to leave these instructions...

Page 4: ...8 7 8 33 3 4 3 1 4 Front 4 5 8 Rear at the conduit location 6 1 4 Rear on Model JP968 2 MIN clearance from cutout to side wall on the left of the unit 30 MIN clearance from countertop to unprotected u...

Page 5: ...terature package Place a towel or tablecloth onto the countertop Lay the cooktop upside down onto the protected surface B5 Screw the Hold Down Bracket to the side of the cooktop unit Repeat for opposi...

Page 6: ...to the cooktop Make final check that all required clearances are met B7 Open the cabinet door and screw the Hold Down Brackets to the cabinet sides with the screws provided B COOKTOP Hold Down Bracke...

Page 7: ...nductor green or bare copper in accordance with local codes When connecting to a 3 conductor branch circuit if local codes permit connect the bare ground connector lead of the cooktop to the branch ci...

Page 8: ...ist NOTE TO ELECTRICIAN The power leads supplied with this appliance are UL recognized for connections to larger gauge household wiring The insulation of these leads is rated at temperatures much high...

Reviews: