– 43 –
Microwave Unit Dead
Check fuse.
Is fuse blown?
Check:
120 VAC
Magnetron TCO
Flame TCO
All OK?
NO
Replace PBC.
Repair or replace
faulty component.
NO
Visually inspect
varistor.
Varistor OK?
Replace PCB.
NO
Perform Monitor
Switch Test.
Pass test?
Replace monitor.
NO
Perform High-
Voltage
Transformer Test.
Pass test?
Replace high-
voltage
transformer.
NO
YES
Perform High-
Voltage Capacitor
Test.
Pass test?
Replace high-
voltage capacitor.
NO
YES
Perform
Magnetron Test.
Pass test?
YES
Replace
magnetron.
NO
System checks
normal. Replace
fuse.
YES
Check for continuity:
Black wire - line-in to
RY2.
White wire - CON02
connector to neutral.
Continuity OK?
YES
Repair circuit.
NO
YES
YES
YES
Summary of Contents for JKP18 Series
Page 47: ... 45 Schematics and Wiring Diagrams Models ZEK957 JKP56 and JKP45 Schematic ...
Page 48: ... 46 Model JKP27 Schematic ...
Page 49: ... 47 Models ZEK937 JKP18 and JKP15 Schematic ...
Page 50: ... 48 d Model JKS05 Schematic ...
Page 51: ... 49 Model JCKS05 Schematic ...
Page 52: ... 50 Models JCKP18 and JCKP15 Schematic ...
Page 53: ... 51 Model JKP85 Schematic ...
Page 54: ... 52 Microwave Schematic FAN THERM SW N O ...
Page 55: ... 53 Model ZEK957 Wiring Diagram ...
Page 56: ... 54 Model ZEK937 Wiring Diagram ...
Page 57: ... 55 Model JKP56 Wiring Diagram ...
Page 58: ... 56 Model JKP45 Wiring Diagram ...
Page 59: ... 57 Model JKP27 Wiring Diagram ...
Page 60: ... 58 Model JCKP18 Wiring Diagram ...
Page 61: ... 59 Model JKP18 Wiring Diagram ...
Page 62: ... 60 Model JCKP15 Wiring Diagram ...
Page 63: ... 61 Model JKP15 Wiring Diagram ...
Page 64: ... 62 Model JCKS05 Wiring Diagram ...
Page 65: ... 63 Model JKS05 Wiring Diagram ...
Page 66: ... 64 Model JKP85 Wiring Diagram ...
Page 67: ... 65 Microwave Wiring Diagram FAN THERMALSW N O ...