GE Title or job number
11/26/2013
Troubleshooting-
Bake circuit
If NO bake element function, with power
removed, (LOTO) check resistance from PR
wire on RLY100 to Y wire on RLY101
should be approx. 35-40 Ω If ok, check
between Y on RLY101 to O on RLY102
should be approx. 20 Ω If ∞ (open) suspect
HIGH LIMIT is open. NOTE: Unit should
also have no BROIL function if HIGH LIMIT
is open.