7
Installation Instructions
INSTALLATION OVER
BUILT-IN OVEN
See built-in oven installation for complete
installation instructions.
6
CHECK FOR LEAKS
Check for leaks. After connecting the
cooktop to gas, check system for leaks with
a manometer. If a manometer is not available,
turn the gas supply on to the cooktop and
use a liquid leak detector at all joints and
connections to check for leaks. Tighten all
connections if necessary to prevent gas
leakage in the cooktop or supply line.
Check alignment of valves after connecting
the cooktop to the gas supply to be sure
the manifold pipe has not been moved.
A misalignment could cause the valve knob
stem to rub on the control panel, resulting
in a gas leak at the valve.
DO NOT USE OPEN FLAME TO CHECK
FOR LEAKS!
Disconnect this cooktop and its individual
shutoff valve
from the gas supply piping
system during any pressure testing of
that system at test pressures greater than
1/2
″
psig.
Isolate the cooktop
from the gas supply
piping system by closing its individual shutoff
valve during any pressure testing of the gas
supply system at test pressures equal to or
less than 1/2
″
psig.
5
5” To Center of
2” Dia. Hole From
Countertop
2
″
Dia. Hole
(20-7/8
″
from front
of Countertop to
Hole Center)
Cabinet Sides
90° Street El