background image

Translation of the original instructions

Installation and operating instructions

ELECTRIC PASTA COOKER FOR

PROFESSIONAL USE

CP-74ET CP-76ET CP-78ET CPT-74ET CPT-76ET CPA-74ET CPA-76ET

CPA-78ET

Model LIBR.ISTR.CP70E CON SIC.

Code 563005504

Review 1

Edition date 22/01/2019

Language English

LOTUS S.p.A.

Via Calmaor, 46

31020 San Vendemiano

+39 0438 778020

+39 0438 778277

Summary of Contents for CP-74ET

Page 1: ...LECTRIC PASTA COOKER FOR PROFESSIONAL USE CP 74ET CP 76ET CP 78ET CPT 74ET CPT 76ET CPA 74ET CPA 76ET CPA 78ET Model LIBR ISTR CP70E CON SIC Code 563005504 Review 1 Edition date 22 01 2019 Language English LOTUS S p A Via Calmaor 46 31020 San Vendemiano 39 0438 778020 39 0438 778277 ...

Page 2: ...ALLATION 15 3 1 Delivery checks 15 3 2 Removing the packaging 15 3 3 Mechanical installation 15 3 4 Electrical gas connections 15 3 5 Water connection and drainage 17 4 INSTRUCTIONS FOR USE 18 4 1 General information 18 4 2 Turning on the appliance 18 4 3 Switching the appliance off 18 4 4 Emptying the tank 19 4 5 Top appliances bowl emptying 19 4 6 Safety thermostat 19 4 7 Pasta cooker with autom...

Page 3: ...INTRODUCTION Translation of the original instructions 3 1 INTRODUCTION 1 1 Installation drawing FIG 1 CP 7 E A Data Plate B Electrical connection D Water connection R 3 4 M E Water drain R 1 M ...

Page 4: ...INTRODUCTION Translation of the original instructions 4 FIG 2 CP 76G CPA 76G A Data Plate B Electrical connection D Water connection R 3 4 M E Water drain R 1 M ...

Page 5: ...INTRODUCTION Translation of the original instructions 5 FIG 3 CPT A Data Plate B Electrical connection ...

Page 6: ...TRODUCTION Translation of the original instructions 6 1 2 Components FIG A 1 Knob 2 White indicator light 3 Green indicator light 4 Water discharge 5 Safety thermostat accessibility 6 Threaded closing cap ...

Page 7: ...INTRODUCTION Translation of the original instructions 7 FIG B CP Water filling tap FIG C ROTARY RESISTANCE 1 O rings 2 Rotary heating element ...

Page 8: ...tions 8 WIRING DIAGRAM CPT 74ET CPT 76ET D 1 Water level control unit 2 Switch 3 Power supply terminal board 4 Switching terminal board 5 Heating element 6 Level probe 7 White indicator light 8 Red indicator light 9 Green indicator light 10 Contactor ...

Page 9: ...n of the original instructions 9 WIRING DIAGRAM CP 74ET CP 76ET CP 78ET E 1 Switch 2 Power supply terminal board 3 Switching terminal board 4 Heating element 5 White indicator light 6 Green indicator light 7 Safety thermostat ...

Page 10: ...CPA 76ET CPA 78ET F 1 Water level control unit 2 Switch 3 Bipolar diverter 4 Water solenoid 5 Bipolar switch 6 Power supply terminal board 7 Switching terminal board 8 Heating element 9 Level probe 10 White indicator light 11 Red indicator light 12 Green indicator light 13 Contactor ...

Page 11: ...INTRODUCTION Translation of the original instructions 11 Wiring diagram reference table MODELS TERMINAL BOARD CP 74ET CP 76ET FIG E CP 78ET FIG E FIG E CPA 74ET CPA 76ET FIG F CPA 78ET FIG F FIG F ...

Page 12: ...INTRODUCTION Translation of the original instructions 12 1 3 Example installation of the appliance ...

Page 13: ...e electrical safety of this equipment is only ensured when it is correctly connected to an effective ground earth system as required by current electrical safety standards The manufacturer cannot be held liable for any damage caused if the system is not connected to ground earth Before carrying out any cleaning or maintenance tasks on the equipment unplug it from the electricity mains In the event...

Page 14: ...ndicates the obligation of separate collection The penalties provided for in the event of improper disposal of RAEE Waste Electrical and Electronic Equipment are those provided for by the national transpositions of European Directives 2012 19 EU 2 3 Technical data table Electrical technical data table CP S70E MODEL DIMENSIONS POWER SUPPLY MAXIMUM POWER kW MAXIMUM INPUT A Silicon POWER SUPPLY CABLE...

Page 15: ... not install the appliance near equipment machines used in cold processes If the appliance has to be installed close to cold process equipment it is advisable to install non combustible thermal insulating material and or neutral elements between them 3 4 Electrical gas connections Before being offered for sale on the market the appliance was subjected to gas and electrical testing as required The ...

Page 16: ... of it so that the device can be fully disconnected from the mains this device must have a contact aperture of at least 3 mm The connection terminal is located behind the rear wall Proceed as follows to install the power supply cable Remove the rear panel Pass the new connection cable through the cable gland connect the leads to the corresponding terminal on the terminal block and fasten them secu...

Page 17: ...hout bends to avoid bottlenecks or siphon effects Water is drained by gravity Inasmuch it is essential that the drain is below the exit point of the pipe Commissioning before using the appliance clean it carefully especially the tank see the cleaning and care section Check the appliance s water connection and operate it in accordance with the instructions given below Warning The appliance must onl...

Page 18: ...fore carrying out any cleaning or maintenance operation Do not operate the appliance without water in the tank 4 2 Turning on the appliance When the appliance is powered up the red indicator light flashes briefly for about 1 2 second If there is no water in the tank the red indicator light continues flashing Open the water tap to fill the tank up to the level mark filling must be higher than the m...

Page 19: ...red to have a suitable recipient for emptying the water oil Insert the drain tube as shown on the drawing position the container Push the safety device upwards against the involuntary openings A and move the lever B Warning Pay close attention to the distance between the appliance and the edges of the support 4 6 Safety thermostat The appliance is equipped with a safety thermostat that cuts off th...

Page 20: ...e heating element is immediately activated and after 3 sec automatic refilling is interrupted The system monitors the filling phase through a TIME OUT Slow refilling button When the slow refilling button is active the system fills the tank slowly to prevent possible foaming Level button The level button defines the level of water in the tank high level for cooking pasta low level for steaming Warn...

Page 21: ... caused it to trip broken or disconnected level probes water system problems drain tap open and then switch the system OFF ON 4 8 Characteristics of the feed water The inlet must be supplied with drinkable water having the specific characteristics listed below otherwise the warranty will be forfeited Total hardness between 0 5 and 5 French degrees to reduce the formation of scale Pressure between ...

Page 22: ...ce and its safety systems Warning For maintenance replacement of components order and use only original spare parts Replacing parts must exclusively be performed by authorised and or qualified personnel When replacing the electrical components of the machine and the electrical panels scrupulously follow the technical characteristics for the replacement component indicated on the component itself T...

Page 23: ... remove the panel and remove the wires connecting the heating element Unscrew the two 8 mm screws that fasten the bracket to the heating element and pull out the bracket until it can be removed At this point the heating element can be removed from inside the bowl pushing it towards the draught diverter Also replace the 3 o rings see point 1 in figure C and apply a bit of grease to facilitate the o...

Page 24: ...s are available commercially but a diluted solution of acetic acid can also be used To clean STAINLESS STEEL appliances it is advisable to use detergents specifically formulated for this material For minor cleaning a mild washing up liquid solution may also be used Do not wash the appliance with jets of water under pressure Avoid using detergents containing abrasive powders or bleaches of any kind...

Reviews: