CONNECTOR HOOKUP
Pressure
regulator
Gas Flow into Range
Gas Flow into Range
Flex
connector
(6 ft. max.)
Adapter
Installer: Inform the consumer of the location of the gas shut-off valve.
1/2
”
or 3/4
”
Gas pipe
Adapter
Gas
shut-off
valve
Pressure
regulator
Elbow
Elbow
Nipple
Union
Nipple
Gas
shut-off
valve
1/2
”
or 3/4
”
Gas pipe
Flexible
Option
Rigid Pipe
Option
1
GAS SUPPLY
WARNING
Fire Hazard: Do not use
a flame to check for gas leaks.
WARNING
Explosion Hazard: Do
not exceed 25 ft-lbs of torque when making
gas line connections. Overtightening may
crack the pressure regulator resulting in fire
or explosion hazard.
Gas Pressure Regulator
You must use the gas pressure regulator
supplied with this range. For proper operations
the inlet pressure to the regulator should be as
follows:
Natural Gas:
Minimum pressure: 6” of Water Column
Maximum pressure: 13” of Water Column
Propane Gas:
Minimum pressure: 11” of Water Column
Maximum pressure: 13” of Water Column
If you are not sure about the inlet pressure
contact local gas supplier.
Shut off the main gas supply valve before
disconnecting the old range and leave it off
until the new hook-up has been completed.
Don’t forget to relight the pilot on other gas
appliances when you turn the gas back on.
Because hard piping restricts movement of
the range, the use of a CSA International-
certified flexible metal appliance connector is
recommended unless local codes require a
hard-piped connection.
If the hard piping method is used, you must
carefully align the pipe; the range cannot be
moved after the connection is made.
To prevent gas leaks, put pipe joint compound
on, or wrap pipe thread tape with Teflon*
around, all male (external) pipe threads.
A. Install a manual shut-off valve in the gas line
in an easily accessed location outside of the
range. Make sure everyone operating the
range knows where and how to shut off the
gas supply to the range.
B. Install male 1/2” flare union adapter to the
1/2” NPT internal thread at inlet of regulator.
Use a backup wrench on the regulator fitting
to avoid damage.
C. Install male 1/2” or 3/4” flare union adapter
to the NPT internal thread of the manual
shut-off valve, taking care to back-up the
shut-off valve to keep it from turning.
D. Connect flexible metal appliance connector
to the adapter on the range. Position range
to permit connection at the shut-off valve.
E. When all connections have been made,
make sure all range controls are in the off
position and turn on the main gas supply
valve. Use a liquid leak detector at all joints
and connections to check for leaks in the
system.
When using pressures greater than 1/2 psig
to pressure test the gas supply system of the
residence, disconnect the range and individual
shut-off valve from the gas supply piping. When
using pressures of 1/2 psig or less to pressure
test the gas supply system, simply isolate the
range from the gas supply system by closing
the individual shut-off valve.
When checking for proper operation of the
regulator, the inlet pressure must be at least 1”
greater than the operating (manifold) pressure
as given on rating label of product.
*Teflon: Registered trademark of DuPont
2
ELECTRICAL
CONNECTIONS
WARNING
Shock Hazard: This
appliance must be properly grounded.
Failure to do so can result in electric shock.
Electrical Requirements -
120-volt, 60 Hertz,
properly grounded dedicated circuit protected by
a 15-amp or 20-amp circuit breaker or time delay
fuse.
Note:
Use of automatic, wireless, or wired
external switches that shut off power to the
appliance are not recommended for this
product.
Grounding
The power cord of this appliance is equipped
with a three-prong (grounding) plug which plugs
into a standard three-prong grounding wall
receptacle to minimize the possibility of electric
shock hazard from this appliance.
The customer should have the wall receptacle
and circuit checked by a qualified electrician to
make sure the receptacle is properly grounded.
Where a standard two-prong wall receptacle
is encountered, it is the personal responsibility
and obligation of the customer to have it
replaced with a properly grounded three-prong
wall receptacle.
DO NOT, UNDER ANY CIRCUMSTANCES,
CUT OR REMOVE THE THIRD (GROUND)
PRONG FROM THE POWER CORD. DO
NOT USE AN ADAPTER. DO NOT USE AN
EXTENSION CORD.
Ground Fault Circuit Interrupters (GFCI’s) are
not required or recommended for gas range
receptacles. Performance of the range will not
be affected if operated on a GFCI-protected
circuit but occasional nuisance tripping of the
GFCI breaker is possible.
Ensure proper
ground exists
before use
3
SURFACE BURNERS
WARNING
Fire or Explosion Hazard:
Do not operate the burner without all burner
parts in place.
A.
Burners -
Place surface burners into
corresponding positions on cooktop.
B.
Caps -
Place caps on proper size burner.
C.
Grates -
The left and right grates are
interchangeable. Place the grates on the
cooktop.
or
Front right burner
(JGB860 Models only)
Electrode
Hole
Cap
Electrode
Cap
Burner
Left
Grate
Right
Grate
Center
Grate or Griddle