background image

CONNECTOR HOOKUP

Pressure 

regulator

Gas Flow into Range

Gas Flow into Range

Flex 

connector 

(6 ft. max.)

Adapter

Installer: Inform the consumer of the location of the gas shut-off valve.

1/2

 or 3/4

  

Gas pipe

Adapter

Gas  

shut-off  

valve

Pressure  

regulator

Elbow

Elbow

Nipple

Union

Nipple

Gas  

shut-off  

valve

1/2

 or 3/4

 

Gas pipe

Flexible

Option

Rigid Pipe

Option

1

  GAS SUPPLY

WARNING

  Fire Hazard: Do not use 

a flame to check for gas leaks.

WARNING

  Explosion Hazard: Do 

not exceed 25 ft-lbs of torque when making 

gas line connections. Overtightening may 

crack the pressure regulator resulting in fire 

or explosion hazard.
Gas Pressure Regulator

You must use the gas pressure regulator 

supplied with this range. For proper operations 

the inlet pressure to the regulator should be as 

follows:

   Natural  Gas:

  Minimum pressure: 6” of Water Column

  Maximum pressure: 13” of Water Column

   Propane  Gas:

  Minimum pressure: 11” of Water Column

  Maximum pressure: 13” of Water Column
If you are not sure about the inlet pressure 

contact local gas supplier.

Shut off the main gas supply valve before 

disconnecting the old range and leave it off 

until the new hook-up has been completed. 

Don’t forget to relight the pilot on other gas 

appliances when you turn the gas back on.

Because hard piping restricts movement of 

the range, the use of a CSA International-

certified flexible metal appliance connector is 

recommended unless local codes require a 

hard-piped connection. 

If the hard piping method is used, you must 

carefully align the pipe; the range cannot be 

moved after the connection is made.

To prevent gas leaks, put pipe joint compound 

on, or wrap pipe thread tape with Teflon* 

around, all male (external) pipe threads. 

A.  Install a manual shut-off valve in the gas line 

in an easily accessed location outside of the 

range. Make sure everyone operating the 

range knows where and how to shut off the 

gas supply to the range.

B.  Install male 1/2” flare union adapter to the 

1/2” NPT internal thread at inlet of regulator. 

Use a backup wrench on the regulator fitting 

to avoid damage.

C.  Install male 1/2” or 3/4” flare union adapter 

to the NPT internal thread of the manual 

shut-off valve, taking care to back-up the 

shut-off valve to keep it from turning.

D.  Connect flexible metal appliance connector 

to the adapter on the range. Position range 

to permit connection at the shut-off valve.

E.  When all connections have been made, 

make sure all range controls are in the off 

position and turn on the main gas supply 

valve. Use a liquid leak detector at all joints 

and connections to check for leaks in the 

system.

When using pressures greater than 1/2 psig 

to pressure test the gas supply system of the 

residence, disconnect the range and individual 

shut-off valve from the gas supply piping. When 

using pressures of 1/2 psig or less to pressure 

test the gas supply system, simply isolate the 

range from the gas supply system by closing 

the individual shut-off valve.

When checking for proper operation of the 

regulator, the inlet pressure must be at least 1” 

greater than the operating (manifold) pressure 

as given on rating label of product. 

*Teflon: Registered trademark of DuPont

2

  ELECTRICAL 

CONNECTIONS

WARNING

  Shock Hazard: This 

appliance must be properly grounded. 

Failure to do so can result in electric shock.
Electrical Requirements - 

120-volt, 60 Hertz, 

properly grounded dedicated circuit protected by 

a 15-amp or 20-amp circuit breaker or time delay 

fuse.

Note: 

Use of automatic, wireless, or wired 

external switches that shut off power to the 

appliance are not recommended for this 

product.

Grounding

The power cord of this appliance is equipped 

with a three-prong (grounding) plug which plugs 

into a standard three-prong grounding wall 

receptacle to minimize the possibility of electric 

shock hazard from this appliance.
The customer should have the wall receptacle 

and circuit checked by a qualified electrician to 

make sure the receptacle is properly grounded.

Where a standard two-prong wall receptacle 

is encountered, it is the personal responsibility 

and obligation of the customer to have it 

replaced with a properly grounded three-prong 

wall receptacle.

DO NOT, UNDER ANY CIRCUMSTANCES, 

CUT OR REMOVE THE THIRD (GROUND) 

PRONG FROM THE POWER CORD. DO 

NOT USE AN ADAPTER. DO NOT USE AN 

EXTENSION CORD.

Ground Fault Circuit Interrupters (GFCI’s) are 

not required or recommended for gas range 

receptacles. Performance of the range will not 

be affected if operated on a GFCI-protected 

circuit but occasional nuisance tripping of the 

GFCI breaker is possible.

Ensure proper 

ground exists 

before use

3

  SURFACE BURNERS

WARNING

 Fire or Explosion Hazard: 

Do not operate the burner without all burner 
parts in place.

A.  

Burners -

 Place surface burners into 

corresponding positions on cooktop.

B.  

Caps -

 Place caps on proper size burner.

C.  

Grates -

 The left and right grates are 

interchangeable. Place the grates on the 

cooktop.

or

Front right burner

(JGB860 Models only)

Electrode

Hole

Cap

Electrode

Cap

Burner

Left

Grate

Right

Grate

Center 

Grate or Griddle

Summary of Contents for JGBS86SPSS

Page 1: ...ANSI A225 1 NFPA 501A or with local codes In Canada the installation of this range must conform with the current standards CAN CSA A240 latest edition or with local codes When this range is installed...

Page 2: ...S DOUBLE OVEN GAS RANGE Recommended area for 120V outlet on rear wall and area for through the wall conection of pipe stub and shut off valve Recommended area for through the floor connection of pipe...

Page 3: ...l range controls are in the off position and turn on the main gas supply valve Use a liquid leak detector at all joints and connections to check for leaks in the system When using pressures greater th...

Page 4: ...device If not remove the unit and adjust the height of the rear leg so that it is properly engaged Spirit level X Y NOTE Cooktop must be at or above counter Grate Cooktop Counter 6 INSTALL AND CHECK A...

Page 5: ...es instalada en una casa m vil se deber asegurar al piso durante el tr nsito Cualquier m todo para asegurar la cocina es adecuado siempre y cuando se realice conforme con los est ndares que figuran a...

Page 6: ...outlet on rear wall and area for through the wall conection of pipe stub and shut off valve Recommended area for through the floor connection of pipe stub and shut off valve 4 1 2 4 2 8 5 3 14 1 2 9 3...

Page 7: ...ontroles de la cocina est n en la posici n de apagado y encienda la v lvula de suministro principal de gas Use un detector de p rdida de l quido en todas las uniones y conexiones para controlar p rdid...

Page 8: ...orrectamente adherida Nivel de Agua X Y NOTA La placa de cocci n debe estar a la misma altura o m s arriba que la mesada Rejilla Placa de Cocci n Mesada 6 INSTALE Y CONTROLE EL DISPOSITIVO ANTIVOLCADU...

Reviews: