HOW TO CONVERT THE RANGE FOR USE
WITH
OR
NATURAL
GAS
(continued)
❑
CONVERT TOP BURNER
Only valves
with these types of
knobs are adjustable.
VALVES
1.
Turn all top burners to LOW.
2. Remove all four knobs.
3. With a small flat blade
screwdriver, turn the
valve set screws
clockwise to decrease flame
size, counterclockwise to increase
flame size. Adjust until the flame is
about the same height as the top
i
of the
burner.
4. Replace the knobs.
5. Check for flame outage by opening and
closing the oven door several times. If the flame
goes out, increase the flame size.
❑
ADJUST THE SURFACE
(for Models Equipped with Standing Pilots)
small hole near the center
of the manifold panel.
3. To adjust, use a
screwdriver with
a shaft diameter of less than 3/16”. Turn pilot
adjustment screw until pilot is 5/16” high. Do
not reduce the flame to less than 5/16” or pilot
outage may occur. A pilot flame burning higher
than recommended may generate soot (carbon
black) on the bottom of your
I
❑
CHECK QUALITY OF
The
combustion quality of burner flames needs
determined visually.
(A) Yellow
Call for service
(B) Yellow tips on
outer
Normal for
gas
(C)
blue
Normal for natural gas
If burner flames look like (A), call for service.
Normal burner flames should look like (B) or
(C), depending on the type of gas you use.
With
gas, some yellow tipping on outer
cones is normal.
44