background image

For answers to your Monogram

® 

or GE

®

  

appliance questions, visit our website at 

geappliances.com or call GE Answer Center

®

 

service, 800.626.2000.

All GE ranges are equipped 

with an Anti-Tip device. 

The installation of this 

device is an important, 

required step in the  

installation of the range.

JGB770SEF 

GE

®

 30" Free-Standing Gas Convection Range

 

330423

Specification Created 6/13

Electrical Rating: 120V, 60Hz, 9A  
Installation Information:
 Before installing, consult 

installation instructions packed with product  

for  current dimensional data.

Dimensions and Installation Information (in inches)

Minimum to

cabinets on

either side

of the range.

Minimum

clearance

to left wall

Minimum

Minimum

clearance to

right wall

Maximum

depth for

cabinets above

countertops

Front edge of

the range side

panel forward

from cabinet

To cabinets below cooktop

and at the range back

To cabinets

below

cooktop and

at the range

back

18"

6"

30"

30"

13"

6"

36"

0"

0"

1/4"

GAS PIPE AND ELECTRICAL

OUTLET LOCATIONS

SINGLE OVEN GAS RANGE

Recommended area for 120V

outlet on rear wall and area for

through-the-wall conection of

pipe stub and shut-off valve.

Recommended area

for through-the-floor

connection of pipe stub

and shut-off valve.

4 1/2"

4"

2"

8"

5"

3"

14 1/2"

9"

30"

47 5/8"

29 1/2"

w/ handle

27 3/4"

w/o handle

30"

36 1/4"±1/4"

11 1/4"

Minimum to

cabinets on

either side

of the range.

Minimum

clearance

to left wall

Minimum

Minimum

clearance to

right wall

Maximum

depth for

cabinets above

countertops

Front edge of

the range side

panel forward

from cabinet

To cabinets below cooktop

and at the range back

To cabinets

below

cooktop and

at the range

back

18"

6"

30"

30"

13"

6"

36"

0"

0"

1/4"

GAS PIPE AND ELECTRICAL

OUTLET LOCATIONS

SINGLE OVEN GAS RANGE

Recommended area for 120V

outlet on rear wall and area for

through-the-wall conection of

pipe stub and shut-off valve.

Recommended area

for through-the-floor

connection of pipe stub

and shut-off valve.

4 1/2"

4"

2"

8"

5"

3"

14 1/2"

9"

30"

47 5/8"

29 1/2"

w/ handle

27 3/4"

w/o handle

30"

36 1/4"±1/4"

11 1/4"

Minimum to

cabinets on

either side

of the range.

Minimum

clearance

to left wall

Minimum

Minimum

clearance to

right wall

Maximum

depth for

cabinets above

countertops

Front edge of

the range side

panel forward

from cabinet

To cabinets below cooktop

and at the range back

To cabinets

below

cooktop and

at the range

back

18"

6"

30"

30"

13"

6"

36"

0"

0"

1/4"

GAS PIPE AND ELECTRICAL

OUTLET LOCATIONS

SINGLE OVEN GAS RANGE

Recommended area for 120V

outlet on rear wall and area for

through-the-wall conection of

pipe stub and shut-off valve.

Recommended area

for through-the-floor

connection of pipe stub

and shut-off valve.

4 1/2"

4"

2"

8"

5"

3"

14 1/2"

9"

30"

47 5/8"

29 1/2"

w/ handle

27 3/4"

w/o handle

30"

36 1/4"±1/4"

11 1/4"

Reviews: