background image

1

30" ELECTRIC RANGE INSTALLATION INSTRUCTIONS

1.  Clearances and Dimensions

a. Provide adequate clearances between the range and adjacent combustible surfaces.
b.  Location—Check location where the range will be installed. Check for proper electrical supply and the stability of floor.
c. Dimensions that are shown must be used. Given dimensions provide minimum clearance. Contact surface must 

be solid and level.

*  30" minimum clearance between the top of the cooking surface 

and the bottom of an unprotected wood or metal cabinet; or 24 " 
minimum when bottom of wood or metal cabinet is protected by not 
less than ¼" flame retardant millboard covered with not less than 
no. 28 MSG sheet steel, 0.015" stainless steel, 0.024" aluminum 
or  0.020" copper. The minimum clearance is 0" for the rear of the 
range. Follow all dimension requirements provided above to prevent 
property damage, potential fire hazard, and incorrect countertop 
and cabinet cuts.

Avoid locating cabinet storage space above the surface units 

to eliminate the possibility of cabinets catching on fire, or 

personal burns from reaching for the cabinets over the heated 

units. If cabinet storage is to be provided, risk can be reduced by 

installing a range hood that projects horizontally a minimum of 

5" beyond the bottom of the cabinets.

Printed in United States 

 

318201724 (0904) Rev. A

FRONT

VIEW

BACK

VIEW

1/8

FRONT

VIEW

TYPICAL CABINET INSTALLATION

SIDE

VIEW

Important Notes to the Installer

1.  Read all instructions contained in these installation instructions 

before installing the appliance.

2.  Remove all packing material before connecting the electrical 

supply to the appliance.

3.  Observe all governing codes and ordinances.
4.  Be sure to leave these instructions with the consumer.

Important Note to the Consumer

Keep these instructions with your Use and Care Guide for future reference.

All dimensions for 

electrical outlet 

location are maximum.

Cubed area shows 
where the electrical 
outlet must be 
installed for the 
range to be flush to 
the wall.

Wall

Edge

Terminal 

Block

Location

INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.

IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. 

READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.

 FOR YOUR SAFETY: Do not store or use gasoline or other 

flammable vapors and liquids in the vicinity of this or any other appliance.

Canada

United States

Summary of Contents for 318201724

Page 1: ...ing for the cabinets over the heated units If cabinet storage is to be provided risk can be reduced by installing a range hood that projects horizontally a minimum of 5 beyond the bottom of the cabinets Printed in United States 318201724 0904 Rev A FRONT VIEW BACK VIEW 1 8 FRONT VIEW TYPICAL CABINET INSTALLATION SIDE VIEW Important Notes to the Installer 1 Read all instructions contained in these ...

Page 2: ...trical code requirements This appliance may be connected by means of permanent Hard Wiring or Power Supply Cord Kit When hard wiring do not leave excess wire in range compartment Excess wire in the range compartment may not allow the access cover to be replaced properly and could create a potential electrical hazard if wires become pinched When using flexible conduit or range cable use flex connec...

Page 3: ...e Wire Ground Bare Copper Wire To 240 V Receptacle A User Supplied Strain relief Must Be Installed at This Location Black Wire 1 1 8 2 9cm Dia Direct Connection Hole Punch Out Knockout for 1 3 8 3 5cm Dia Cord Kit Hole NOTE Be sure to remove the supplied grounding strap Figure 4 Three Conductor Wire Connection to Range If local codes permit connection of the frame grounding conductor to the neutra...

Page 4: ...ogether Figure 5 3 Wire Grounded Neutral Electrical System Example Junction Box Cable from Residence Junction Box White Wire U L listed Conduit Connector or CSA listed Cable from Appliance Green or Bare Copper Wire Red Wires Neutral white Wire Black Wires NOTE Be sure to remove the supplied grounding strap Where local codes DO NOT permit connecting the appliance grounding conductor to the neutral ...

Page 5: ...open door or if a child climbs upon it Serious injury may result from spilled hot liquids or from the range itself Refer to the instructions located in the anti tip bracket package for proper bracket installation If the range is moved to a different location the anti tip bracket must also be moved and installed with the range For the bracket installation instructions refer to the anti tip bracket ...

Page 6: ...6 30 ELECTRIC RANGE INSTALLATION INSTRUCTIONS NOTES ...

Page 7: ...tencia de suministro eléctrico adecuado y la estabilidad del piso c Se deben usar las medidas indicadas Las dimensiones indicadas proporcionan espacio mínimo La superficie de contacto debe ser sólida y estar a nivel Mínimo a la pared a cada lado de la cocina o la cocina a 36 de alto Mínimo a los gabinetes sobre cada lado de la estufa VISTA FRONTAL vista frontal VISTA POSTERIOR Notas importantes pa...

Page 8: ...xión eléctrica Este aparato debe estar instalado en forma apropiada y puesto a tierra por un técnico calificado de acuerdo con el National Electric Code Código Nacional de Electricidad ANSI NFPA No 70 última edición y con los requerimientos de electricidad de los códigos locales Este aparato puede ser conectado por medio de una extensión a un tomacorriente local permanente o por medio de Juego de ...

Page 9: ...minal y del armazón del electrodoméstico Retenga el tornillo de la base 3 Utilizar los tuercas suministraron en el paquete de la literatura para conectar el alambre de tierra verde del cable de bronce del suministro eléctrico al armazón del electrodoméstico con el tornillo de la base usando el hoyo del armazón por donde retiró la correa de la base vea figura 4 4 Conecte el alambre neutral blanco d...

Page 10: ...mbre verde o cobre desnudo el alambre blanco del cable del electrodoméstico y el alambre neutral blanco juntos b Conecte los dos alambres negros juntos c Conecte los dos alambres rojos juntos Donde los códigos locales NO permitan conectar el conductor de puesta a tierra del electrodoméstico al neutral blanco o si está conectado con un sistema a 4 alambres vea figura 6 1 Desconecte el suministro el...

Page 11: ...ico en el horno Si no se instalan estes soportes la estufa se volcará si se coloca peso excesivo sobre una puerta abierta o si un niño se subiera al aparato Puede tener como resultado lesiones serias como consecuencia de derrame de líquidos calientes o por que la estufa misma puede caerse Estudie las instrucciones en esta página para una instalación apropiada Si la estufa se mueve a un lugar difer...

Page 12: ...6 INSTRUCCIONES PARA INSTALACION DE LA ESTUFA ELECTRICA DE 30 NOTAS ...