30" ELECTRIC RANGE INSTALLATION INSTRUCTIONS

2.  Install Anti-Tip Bracket 

(See instructions on 

page 4.)

The user is responsible for connecting the power supply cord 
to the connection block located behind the back panel access 
cover.
This appliance may be connected by means of permanent 
"hard wiring"; flexible armored or nonmetallic shielded copper 
cable (when local code allow it) or by means of a power supply 
cord kit.

NOTE: 

Electric Slide-in Range is shipped from factory with 1 

1/8" (2.9 cm) dia. hole as shown on figure 4. If a larger hole is 
required, punch out the knockout.

 Risk of fire or electrical shock exists if 

an incorrect size range cord kit is used, the Installation 
Instructions are not followed, or the strain relief bracket 
is discarded.

For mobile homes, new installations or recreational vehicles, 
use only a power supply kit designed for a range at 125V/250V 
50A recommended (minimum 40A). Cord must have either 
3 (when local code permits grounding through neutral) or 4 
conductors. Terminal on end of wires must be either closed 
loop or open spade lug with upturned ends. Cord must have 
strain-relief clamp. If a 50A circuit is used, a 50A power cord 
must be used.

 Do not loosen the nuts which secure the 

factory-installed range wiring to terminal block while 
connecting range. Electrical failure or loss of electrical 
connection may occur.

4.  Electrical Connection Requirements

This appliance must be properly installed and 
grounded by a qualified technician in accordance with 
the National Electrical Code ANSI/NFPA No. 70--latest 
edition--and local electrical code requirements.
This appliance may be connected by means of 
permanent "Hard Wiring" or "Power Supply Cord Kit."
When hard wiring, do not leave excess wire in range 
compartment. Excess wire in the range compartment 
may not allow the access cover to be replaced 
properly, and could create a potential electrical hazard 
if wires become pinched. When using flexible conduit 
or range cable, use flex connector or range cable strain 
relief.
NOTE: Only use copper wire in connection to terminal 
block.

4.1 Models Requiring Power Supply Cord Kit

Figure 2 – 3-Wire Cord Kit

Figure 1

3.  Serial Plate 

Information

 

The serial plate is 
located as shown. 
See the serial plate 
for the following 
information:

 

A.  Model, lot and 
serial number of 
range.

 

B.  Kilowatt rating 
(power requirements).

 

C.  Voltage ratings.

Electrical Shock Hazard

•  Electrical ground is required on this appliance.
•  Do not connect to the electrical supply until 

appliance is permanently grounded.

•  Disconnect power to the circuit breaker or fuse box 

before making the electrical connection.

•  This appliance must be connected to a grounded, 

metallic, permanent wiring system, or a grounding 
connector should be connected to the grounding 
terminal or wire lead on the appliance.

Failure to do any of the above could result in a fire, 
personal injury or electrical shock.

 This appliance is manufactured with 

the frame grounded by connection of a grounding 
strap between the neutral power supply terminal 
and the frame. If used in USA, in a new branch circuit 
installation (1996 NEC), mobile home or recreational 
vehicule, where local code do not permit grounding 
through neutral (white) wire or in Canada; remove the 
grounding strap from the frame and cut the other end, 
near the neutral terminal. Connect the appliance in 
usual manner.

Summary of Contents for 318201724

Page 1: ...ing for the cabinets over the heated units If cabinet storage is to be provided risk can be reduced by installing a range hood that projects horizontally a minimum of 5 beyond the bottom of the cabinets Printed in United States 318201724 0904 Rev A FRONT VIEW BACK VIEW 1 8 FRONT VIEW TYPICAL CABINET INSTALLATION SIDE VIEW Important Notes to the Installer 1 Read all instructions contained in these ...

Page 2: ...trical code requirements This appliance may be connected by means of permanent Hard Wiring or Power Supply Cord Kit When hard wiring do not leave excess wire in range compartment Excess wire in the range compartment may not allow the access cover to be replaced properly and could create a potential electrical hazard if wires become pinched When using flexible conduit or range cable use flex connec...

Page 3: ...e Wire Ground Bare Copper Wire To 240 V Receptacle A User Supplied Strain relief Must Be Installed at This Location Black Wire 1 1 8 2 9cm Dia Direct Connection Hole Punch Out Knockout for 1 3 8 3 5cm Dia Cord Kit Hole NOTE Be sure to remove the supplied grounding strap Figure 4 Three Conductor Wire Connection to Range If local codes permit connection of the frame grounding conductor to the neutra...

Page 4: ...ogether Figure 5 3 Wire Grounded Neutral Electrical System Example Junction Box Cable from Residence Junction Box White Wire U L listed Conduit Connector or CSA listed Cable from Appliance Green or Bare Copper Wire Red Wires Neutral white Wire Black Wires NOTE Be sure to remove the supplied grounding strap Where local codes DO NOT permit connecting the appliance grounding conductor to the neutral ...

Page 5: ...open door or if a child climbs upon it Serious injury may result from spilled hot liquids or from the range itself Refer to the instructions located in the anti tip bracket package for proper bracket installation If the range is moved to a different location the anti tip bracket must also be moved and installed with the range For the bracket installation instructions refer to the anti tip bracket ...

Page 6: ...6 30 ELECTRIC RANGE INSTALLATION INSTRUCTIONS NOTES ...

Page 7: ...tencia de suministro eléctrico adecuado y la estabilidad del piso c Se deben usar las medidas indicadas Las dimensiones indicadas proporcionan espacio mínimo La superficie de contacto debe ser sólida y estar a nivel Mínimo a la pared a cada lado de la cocina o la cocina a 36 de alto Mínimo a los gabinetes sobre cada lado de la estufa VISTA FRONTAL vista frontal VISTA POSTERIOR Notas importantes pa...

Page 8: ...xión eléctrica Este aparato debe estar instalado en forma apropiada y puesto a tierra por un técnico calificado de acuerdo con el National Electric Code Código Nacional de Electricidad ANSI NFPA No 70 última edición y con los requerimientos de electricidad de los códigos locales Este aparato puede ser conectado por medio de una extensión a un tomacorriente local permanente o por medio de Juego de ...

Page 9: ...minal y del armazón del electrodoméstico Retenga el tornillo de la base 3 Utilizar los tuercas suministraron en el paquete de la literatura para conectar el alambre de tierra verde del cable de bronce del suministro eléctrico al armazón del electrodoméstico con el tornillo de la base usando el hoyo del armazón por donde retiró la correa de la base vea figura 4 4 Conecte el alambre neutral blanco d...

Page 10: ...mbre verde o cobre desnudo el alambre blanco del cable del electrodoméstico y el alambre neutral blanco juntos b Conecte los dos alambres negros juntos c Conecte los dos alambres rojos juntos Donde los códigos locales NO permitan conectar el conductor de puesta a tierra del electrodoméstico al neutral blanco o si está conectado con un sistema a 4 alambres vea figura 6 1 Desconecte el suministro el...

Page 11: ...ico en el horno Si no se instalan estes soportes la estufa se volcará si se coloca peso excesivo sobre una puerta abierta o si un niño se subiera al aparato Puede tener como resultado lesiones serias como consecuencia de derrame de líquidos calientes o por que la estufa misma puede caerse Estudie las instrucciones en esta página para una instalación apropiada Si la estufa se mueve a un lugar difer...

Page 12: ...6 INSTRUCCIONES PARA INSTALACION DE LA ESTUFA ELECTRICA DE 30 NOTAS ...

Reviews: