background image

NOTE: 

Control display will flash “LOCK DOOR”

if the door switch is in the “C” to “NC” position

(door open).

 The words “LOCK DOOR” will flash on and

   off in the display while the lock motor is in

   motion, When the door is locked, the words

   “LOCKED DOOR” remain illuminated in the

   display.

 CAM - The cam on the motor performs two

   functions:

   1. Positions the lock hokk in the door to

       prevent opening during clean operation.

   2. Operates the lock switches which tell the

       control if the door is unlocked or locked

       and ready for Clean operation.

FAILURE

CODE

MEANING

CORRECTION

-F0- Shorted OFF key (Mem-

brane) or GT Error

Perform glass touch board key panel test.

-F2- Over temperature

1. Inside oven cavity as measured

    by sensor over 650°F unlatched or

    915°F latched

-F3- Open oven sensor (under

950 ohms)

-F4- Shorted oven sensor (over

2900 ohms)

-F7- Shorted matrix or START

key

-F8- EEPROM data shift failure

-F9- Cooling fan stalls while above

650°F; open thermal switch in

yellow lead

-FC- Loss of latch motor safety

circuit

- Welded relay contacts

- Cooling fan stalled or blocked

- Airflow to rear of unit

- High resistance in oven sensor leads/connectors

  (especially at sensor in rear) 

- Disconnect power. Disconnect sensor harness from

  control. Measure sensor resistance (white leads) to

  be ~ 1080 ohms at room temperature with 2 ohms

  per degrees change.

- Look for damaged harness terminals is not a bad

  sensor.

Replace control.

Cooling fan or airflow to control area.

If repeated, replace control.

Determine if problem is with keyt panel or control by

disconnecting ribbon cable and measuring flat cable using

pinout chart. Allow up to 1000 ohms when pressing a key.

- Disconmect power Disconnect sensor harness from

  control. Measure sensor resistance (white leads) to

  be ~1080 ohms at room temperature with 2 ohms per

  degree change.

- Separate sensor from harness to determine fault.

ERC FAILURE CODES

The oven may stop operating but not give an F code on the display inmediately.

F codes are stored in nonvolatile EEPROM memory until the same fault occurs

twice consecutively. F codes can be recalled by pressing together TIMER, CLOCK

and 9. While F codes are desplayed, pressing 8 and 6 together will clear them. A

fault must exist continuously for 5 minutes before an F code is recorded (F2 and

F8 are Sooner).

MOTORIZED DOOR LOCK

The motorized door lock assembly is located above the oven. The assembly 

consists of a lock motor cam and switch assembly, lock hook and mounting 

plate.

MOTORIZED DOOR LOCK OPERATION

The lock motor is energized when the control is set for Clean and Clean Time 

is selected. The K4 Relay contacts will close and complete the circuit that 

supplies the voltage to the lock motor.

Lock Motor

Heat Barrier

Lock Hook

Lock Switch

MOTORIZED DOOR LOCK (CONT.)

Motorized Door Lock Operation

:

NOTE: 

To enable proper operation of the door lock, ensure that the door jamb switch

is in “common” to “normally closed” (door closed). This enables power to be delivered

when the door lock closes.

NOTE:

 Display of Control will flash “

LOCK

” if the door switch is in the “

C

” (common)

to “

NO

” (normally open) position (door open).

• The words “

LOCK

” will flash on and off in the display while the lock motor is in

  motion. When the door is locked, the word “

LOCK

” remain illuminated in the dis-

  play.

• CAM - The ca, on the motor performs two functions:

1. Positions the lock in the door to prevent opening during clean operation.

2. Operates the lock switches which tell the control if the door is unlocked or locked

    and ready for clean operation.

NOTE: 

The door lock switch will be open when the latch is locking. Once locked, the

door switch will be closed. 

Lock Switch

 

Door Switch

MODEL JCSS630

SH. 2 of 6     295D1749G018     Pub. Num. 29-6198

Summary of Contents for JCSS630

Page 1: ...TERMINALS L1 TO N FOR CONTROL TO OPERATE 30 RADIANT SLIDE IN CONVECTION SINGLE OVEN RANGE JCSS630 RADIANT SINGLE OVEN Printed in Mexico RADIANT HEATING ELEMENT SYSTEMS Heating Elements The radiant heating element consists of a spiral wound resistance wire attached to microporous insulation with molded ceramic fiber walls in a corrosion protected metal tray The Heating Elements come in various size...

Page 2: ...ohms at room temperature with 2 ohms per degree change Separate sensor from harness to determine fault ERC FAILURE CODES The oven may stop operating but not give an F code on the display inmediately F codes are stored in nonvolatile EEPROM memory until the same fault occurs twice consecutively F codes can be recalled by pressing together TIMER CLOCK and 9 While F codes are desplayed pressing 8 and...

Page 3: ...SIMPLE Imprimé au Mexique SYSTÈMES D ÉLÉMENTS CHAUFFANTS RAYONNANTS Éléments Chauffants L élément chauffant rayonnant se compose d un fil électrique résistant enroulé en spirale attaché à un isolant microporeux avec parois en fibre de céramique moulé dans un plateau en métal protégé contre la corrosion Les éléments chauffants se présentent de tailles variées 6 240 Volt 1200 Watts 6 240 Volt 1500 W...

Page 4: ... Touche 700 710 720 783 Agence 800 810 840 Porte 900 Description Mauvais raccordement de la cuisinière dans les premières 10 minutes Mauvais raccordement de la cuisinière après 10 minutes État de Facteur de Risque Oui Non Non Oui Oui Oui Oui L état du verrou de la porte pour le four 1 ou simple a changé de manière inattendue Appuyez sur Cancel Annuler pour réinitialiser le système Mauvais assembla...

Page 5: ...TOR 1a 2a P RR 1200W L1 L2 N 1b 2b 2b 1b HOT SURFACE LIGHT 2b 1b 2b 1b LR 1500W P 2a 1a PROTECTOR L2 H2 H1 L1 WARNING POWER MUST BE DISCONNECTED BEFORE SERVICING THE APPLIANCE LOCKOUT RELAY NC B B B B W V B B W B B B R R R V W V V W V V V V B B B B V OB O B R NR NB N CW C TACTILE RC15 ELECTRONIC CONTROL 4a LF OUTER 1600W S2 LF INNER 1400W 2a 4 PROTECTOR P1 2 4 P2 4a B R V B YR YB Y 4 1 J502 R Y V ...

Page 6: ... 7 8 9 4 5 6 1 2 3 7 8 9 O YB N W NB C OR CR NR N YB O R YR C NB W CR Y NR TACTILE RC15 CONTROL 1 2 J501 BA BR L1 DBL J401 1 10 R 3 W 8 S 1 V 1 Y 1 O 4 A 1 W 9 N 1 O 4 Y 3 J903 1 3 J902 1 2 LF R V L2 B 6 N O 1 Y 4 P1 4a 2 S2 YR YB P2 S1 V B 5 C 1 Y R YR OR LF 3000W 1 3 2 R V Y YB 5 2 8 4 1 7 6 3 9 5 2 8 4 1 7 S 2 C 2 B 8 R 4 AUXILIARY SW LOWER 1 S 1 C 1 W 7 W 8 R 6 Y 8 B 8 12 11 10 12 11 10 B 7 Y ...