background image

 

 

 

QuickPanel™ Control 

Communication Module 

Quick Installation Guide 

 

PCIF I/O Adapter 

 

 
 
 
 
 
 
 

April 2010 

GFK-2245A 

Summary of Contents for IC693CBL300

Page 1: ...QuickPanel Control Communication Module Quick Installation Guide PCIF I O Adapter April 2010 GFK 2245A ...

Page 2: ...formation contained herein does not purport to cover all details or variations in hardware or software nor to provide for every possible contingency in connection with installation operation or maintenance Features may be described herein which are not present in all hardware and software systems GE Intelligent Platforms as sumes no obligation of notice to holders of this document with respect to ...

Page 3: ...vider ip ge com Technical Support If you have technical problems that cannot be resolved with the information in this guide please contact us by telephone or email or on the web at www ge ip com support Americas Online Technical Support www ge ip com support Phone 1 800 433 2682 International Americas Direct Dial 1 780 420 2010 if toll free 800 option is unavail able Technical Support Email suppor...

Page 4: ...emea ip ge com Customer Care Email customercare emea ip ge com Primary languages of support English French German Italian Czech Spanish Asia Pacific Online Technical Support www ge ip com support Phone 86 400 820 8 208 86 21 3217 4826 India Indonesia and Pakistan Technical Support Email support cn ip ge com China support jp ip ge com Japan support in ip ge com remaining Asia customers Customer Car...

Page 5: ...rates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communica tions Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Note This Class A digital apparatus complies ...

Page 6: ...ecautions when ac cessing the mating connector or the interior of the unit Note The 6 model QuickPanel is shown Other models are similar 1 Disconnect the DC input power terminal block connec tor from your QuickPanel Control unit before connect ing the Communication Module to the unit ...

Page 7: ...n the back of the unit 4 Install the three screws to secure the card in the unit 5 Close the cover Connect your I O network to external connections on the module enclosure see applicable sections for details Caution Be sure to properly align pins in the dual connector upon insertion to avoid damage to the card or the QuickPanel Control ...

Page 8: ...nector Pin Signal Direction 1 SHLD N A 2 DFRAM E Output 3 DFRAM E Output 7 GND N A 8 RUN Output 9 RUN Output 12 P ERR Input 13 P ERR Input 16 DA TA Input Output 17 DA TA Input Output 20 R SEL Output 21 R SEL Output 24 IOCLK Output 25 IOCLK Output ...

Page 9: ... an I O Bus terminator plug catalog number IC693ACC307 Interconnecting cables may be standard length GE expan sion cables or custom length cables Part Number Cable Type IC693CBL300 1 meter Wye cable IC693CBL301 2 meter Wye cable IC693CBL302 15 meter point to point cable Environmental Specifications Storage Temperature 20 to 70 C Operating Temperature 0 to 60 C Operating Humidity 5 to 90 non conden...

Reviews: