ADJUSTABLE FEATURES
SX TRANSISTOR CONTROLS
Page
32
FUNCTION 27
HOUR METER MINUTES
This function adjusts the number of 30 second intervals
registering in the hour meter. This function is typically not
set by an OEM, it is usually only read from the register.
Range
0 to 60 minutes
Resolution
0.5 minutes per set unit
Setting
0 to 120
Example
Setting of 60 = 60 x 0.5 = 30 minutes
FUNCTION 28
STORED STATUS CODE COUNT
POINTER
This register contains the location of the last stored status
code recorded of the 16 stored status codes. These stored
status codes have caused a PMT controller shutdown
and/or disruption of normal vehicle operation.
FUNCTION 29
HOUR METER TENS AND UNITS
HOURS SET
This function allows for the adjustment of the tens and
units hours of the hour meter.
Range
0 to 99
Set
0 to 99
Example
9999 Hours
FUNCTION 30
HOUR METER THOUSANDS
AND HUNDREDS HOURS SET
This function allows for the adjustment of the thousands
and hundreds hours of the hour meter.
Range
0 to 99
Set
0 to 99
Example
9999 Hours
FUNCTION 48
NOT USED
FUNCTION 49
NOT USED
FUNCTION 50
NOT USED
FUNCTION 51
NOT USED
Updated